FC1000/SF1000: EPA 2017 Certification Report

HY-C Company, LLC

Date: May 11, 2017

Project No. G102883416

Page 8 of 17

II.D SUMMARY OF OTHER DATA TABLE 1. – DATA SUMMARY PART A

W fuel

MC ave

Q in

Q out

Θ

Wood Weight as-fired

Run No.

Load % Capacity

Target Load Btu/hr 17,325

Actual Load Btu/hr 16,691

Test Duration

Wood Moisture

Heat Input

Heat Output

Category

Actual Load

% of Max

hrs

lb

% DB 26.12

Btu

Btu

<35% of Max 36-53% of Max 54-76% of max Max capacity

I

3

33.7

9.65

37.73

254,292

161,068

II

4

21,780

24,701

49.9

5.97

36.28

24.98

246,736

147,380

III

1

32,175

30,358

61.3

3.73

36.66

23.27

252,781

113,336

IV

2

49,500

45,000

100.0

3.45

33.21

24.88

226,044

155,250

TABLE 2. – DATA SUMMARY PART B

η del

η SLM

E T

E

E

E g/hr

PM Output Based

Stack Loss Efficiency

Run No.

Load % Capacity

Total PM Emissions

PM Output Based lb/mmBtu Out

PM Rate g/hr 1.53

Delivered Efficiency

Category

g

g/MJ 0.09

%

%

<35% of Max 36-53% of Max 54-76% of max Max capacity

I

3

14.79

0.20

63.3%

73.2%

II

4

11.93

0.18

0.08

2.00

59.7%

69.4%

III

1

12.18

0.24

0.10

3.26

44.8%

70.0%

IV

2

15.79

0.22

0.10

4.58

68.7%

64.8%

Made with FlippingBook - professional solution for displaying marketing and sales documents online