FC1000/SF1000: EPA 2017 Certification Report

HY-C Company, LLC

Date: May 11, 2017

Project No. G102883416

Page 9 of 17

TABLE 3. – WEIGHTED AVERAGE

Emissions lbs/MMBtu Output

CO Emissions g/min

Run No.

Weighting Factor

Delivered Efficiency

Emissions g/MJ

Stack Loss Efficiency

Emissions g/hr

Category

3 4 1 2

0.937 0.292 0.055 0.010 1.293

I

59.284 17.413 3.758

0.082 0.022 0.006 0.001 0.110

68.556 20.243 3.545

0.189 0.052 0.012 0.002 0.198

1.436 0.583 0.250 0.033 2.212

1.671 0.772 0.137 0.027 2.015

II

III IV

0.452 62.57

0.706 71.96

Totals

TABLE 4. – CSA B415.1 RESULTS

CO Emissions (g/min)

Heating Efficiency (% HHV)

Heat Output (Btu/hr)

Run No.

3 4 1 2

1.78 2.65 2.63 2.51

73.2 69.4 70.0 64.8

19,383 28,550 47,265 40,868

Equipment

Inv. Number

Calibration Due

MU

Platform Scale Thermocouples

008 500 713 986

7/25/17 3/28/17 7/25/17 3/27/17 7/25/17 4/6/17 4/6/17 1/31/18 1/31/18 10/25/17

±27g ±4°F

Balance

43 x 10^(-3) grams

Data Logger

±2.04°F

Scale Timer Timer

1134 1212 1213 1413 1414 1420

±27g

±0.3 sec ±0.3 sec

Flow Meter Flow Meter Barometer

±17mL/min ±17mL/min

0.072°F, 0.51%RH, 0.011 in Hg

0.0051 ft 3

DGM

1268

7/16/17