HY-C Company, LLC
Date: May 11, 2017
Project No. G102883416
Page 9 of 17
TABLE 3. – WEIGHTED AVERAGE
Emissions lbs/MMBtu Output
CO Emissions g/min
Run No.
Weighting Factor
Delivered Efficiency
Emissions g/MJ
Stack Loss Efficiency
Emissions g/hr
Category
3 4 1 2
0.937 0.292 0.055 0.010 1.293
I
59.284 17.413 3.758
0.082 0.022 0.006 0.001 0.110
68.556 20.243 3.545
0.189 0.052 0.012 0.002 0.198
1.436 0.583 0.250 0.033 2.212
1.671 0.772 0.137 0.027 2.015
II
III IV
0.452 62.57
0.706 71.96
Totals
TABLE 4. – CSA B415.1 RESULTS
CO Emissions (g/min)
Heating Efficiency (% HHV)
Heat Output (Btu/hr)
Run No.
3 4 1 2
1.78 2.65 2.63 2.51
73.2 69.4 70.0 64.8
19,383 28,550 47,265 40,868
Equipment
Inv. Number
Calibration Due
MU
Platform Scale Thermocouples
008 500 713 986
7/25/17 3/28/17 7/25/17 3/27/17 7/25/17 4/6/17 4/6/17 1/31/18 1/31/18 10/25/17
±27g ±4°F
Balance
43 x 10^(-3) grams
Data Logger
±2.04°F
Scale Timer Timer
1134 1212 1213 1413 1414 1420
±27g
±0.3 sec ±0.3 sec
Flow Meter Flow Meter Barometer
±17mL/min ±17mL/min
0.072°F, 0.51%RH, 0.011 in Hg
0.0051 ft 3
DGM
1268
7/16/17