EPA Emissions Test Report | FC1500, SF2600

HY-C Company, LLC

Date: November 10, 2016

Project No. G102527563

Page 4 of 15

I.

INTRODUCTION

Intertek Testing Services NA (Intertek) has conducted testing for HY-C Company, LLC, on model FC1500 Wood Air Furnace to evaluate all applicable performance requirements included in “Determination of particulate matter emissions from wood forced-air furnaces.” I.A PURPOSE OF TEST The test was conducted to determine if the unit is in accordance with U.S EPA requirements under EPA 40 CFR Part 60 “Standards of Performance for New Residential Wood Heaters, New Residential Hydronic Heaters and Forced-Air Furnaces”. This evaluation was started on June 6, 2016 and completed on June 9, 2016. The following test methods were applicable: ASTM E2515-11- Standard Test Method for Determination of Particulate Matter Emissions Collected by a Dilution Tunnel CSA B415.1-10 - Performance Testing of Solid-Fuel-Burning Heating Appliances I.B LABORATORY The tests on the model FC1500 Wood Forced-Air Furnace were conducted at the Intertek testing Services Laboratory located at 8431 Murphy Drive, Middleton, WI, 53562. The laboratory is accredited by the U.S. EPA, Certificate Number 3. The test was conducted by Ken Slater and observed by Dan Haynes of HY-C Company, LLC. I.C DESCRIPTION OF UNIT The model FC1500 Wood Forced-Air Furnace is constructed of sheet steel. The outer dimensions are 44-inches deep, 50.5-inches high, and 25.5-inches wide. The unit has a fueling door located on the front. (See product drawings.)

Proprietary drawings and manufacturing methods are on file at Intertek in (Intertek location)

Made with FlippingBook - professional solution for displaying marketing and sales documents online