Operations training
High Voltage Standard / V2 PUBLIC HEARING DRAFT 0.1
The participants shall:
Ask and answer questions on why basic cable theory is relevant to a HV working with of HV cables and connector components
INSPECTION, CLEANING & PREPARATION OF T-CONNECTORS
120 min.
The aim of this lesson is to provide participants with an introduction to conducting a high-quality inspection of the HV cable, breakout, connectors and components, and to recognise when to report problem or issues.
After having successfully completed this lesson, the participants can:
18) Explain the key points for a HV cable, breakouts and T-Connector inspection and signs of problems to look out for (Knowledge, intermediate level)
19) Distinguish HV cable, breakouts and T-Connectors in proper and improper conditions for proceeding with the cable connection (Skills, intermediate level)
20) Take responsibility to report any problems identified during breakout inspection (Ability, intermediate level)
ELEMENT 3.1 - HV CABLE AND BREAKOUT INSPECTION
Learning objectives:
21) Explain the key points in a breakout inspection and signs of problems to look out for (Knowledge, intermediate level)
The instructor shall:
Demonstrate the key points in a HV cable breakout inspection, explaining the purpose and importance of every check:
a. correct measurements of breakout (vary up to 2cm)
b.
damage on heat shrink including 4-finger
c.
damage on heat shrink on conductor
Global Wind Organisation / www.globalwindsafety.org
121 / 163