Clean-Resources-NRD-NCE-Series-sell-sheet

Clean Resources - NEXT Air & Gas - NRD-NCE Series non-cycling economy refrigerated air dryers - product sheet

NRD-NCE

15–300 CFM 

NON-CYCLING ECON REFRIGERATED DRYERS

NON-CYCLING ECON REFRIGERATED DRYERS NRD-NCE SERIES | 15–300 CFM

Invest in Productivity and Peace of Mind The Next Air NRD-NCE (15–300 CFM) Series of dryers was developed to meet the needs of its most demanding customers in an economical package. All models are equipped with an electronic board system and a double sensor system that keeps the dewpoint and the condensing pressure under control. The aluminum heat exchanger has been studied and patented in order to offer maximum performance and minimum pressure drop. The NRD-NCE series was developed with total respect for the environment through the use of eco-friendly gases and recyclable materials. Standard Features • Economical design • Suitable for small and medium-scale applications • Double sensor system

• Low pressure drop • Nema-1 standard • Programmable timer drain • Eco-friendly gases and recyclable material

Technical Overview

232 psig

115° F

Class 5 (ISO 8573-1:2010)

Maximum Air Pressure: 

Maximum Ambient Temperature:

Dewpoint:

130° F

Standard

Maximum Air Inlet Temperature: 

UL/CSA certification:

NRD-NCE Series Specifications

Model

Refrigerant

Flow Rate SCFM)

Connection

Weight (lbs)

Dimensions (in) (W x D x H)

Power Supply

3 ⁄

4 ” NPT

40

12.0 x 14.7 x 17.3

115/1/60

NRD-NCE-15

R134a

15

3 ⁄

4 ” NPT

40

12.0 x 14.7 x 17.3

115/1/60

NRD-NCE-20

R134a

20

3 ⁄

4 ” NPT

42

12.0 x 14.7 x 17.3

115/1/60

NRD-NCE-35

R134a

35

3 ⁄

4 ” NPT

46

13.6 x 16.1 x 18.9

115/1/60

NRD-NCE-50

R134a

50

NRD-NCE-75

R134a

75

1” NPT

60

15.7 x 18.2 x 21.3

115/1/60

NRD-NCE-100

R134a

100

1” NPT

77

15.7 x 18.2 x 21.3

115/1/60

NRD-NCE -125

R134a

125

1” NPT

88

15.7 x 18.2 x 21.3

115/1/60

NRD-NCE-150

R134a

150

1” NPT

90

15.7 x 18.2 x 21.3

115/1/60

1 1 ⁄

2 ” NPT

121

21.2 x 21.2 x 26.9

115/1/60

NRD-NCE-175

R407C

175

1 1 ⁄

2 ” NPT

159

20.7 x 24.7 x 44.2

230/1/60

NRD-NCE-220

R407C

220

1 1 ⁄

2 ” NPT

172

20.7 x 24.7 x 44.2

230/1/60

NRD-NCE-300

R407C

300

Capacity Correction Factors Inlet flow rates stated in the specification table assume the following conditions: 100° F inlet temperature, 100° F ambient temperature, and 100 psig operating pressure. For proper operation, compressed air dryers must be sized for the maximum temperatures, minimum pressure and maximum flow rate of the installation. To obtain dryer flow capacity for non-standard conditions use the following formula: Dryer Flow Rate x CF1 x CF2 x CF3 = New Flow Capacity To select a dryer based on the system flow of the compressed air system use the following formula. Then select a dryer that has a flow rate that is equal to or above the minimum required drying capacity. System Flow / CF1 / CF2 / CF3 = Minimum Required Drying Capacity

Correction Factors for Inlet Air Temperature (CF1) Air Temperature (°F) 90 100 110 120 130 Factor 1.11 1.00 0.80 0.65 0.53

Correction Factors for Ambient Temperature (CF2) Ambient Temperature (°F) 80 90 100 110

115

1.00

Factor

1.10

1.07

0.83

0.70

Correction Factors for Operating Pressure (CF3)

100

Inlet Air Pressure (psig)

60

80

120 140 160 180 200

1.00

Factor

0.79 0.91

1.07 1.13 1.18 1.23 1.27

Clean Resources assumes no responsibility or liability for any errors or omissions.

Clean Resources | 1540 Louis Bork Drive, Batavia, IL 60510 | 800-566-0402 | cleanresources.com

v2.1 6-28-2024

Page 1 Page 2

cleanresources.com

Made with FlippingBook - Share PDF online