Clean-Resources-CHD-Series-sell-sheet

HEATLESS REGENERATIVE DRYERS CHD SERIES | 40–5,000 CFM

Product Specifications

CHD Series Specifications

Technical Overview

Inlet Flow Capacity (cfm @100 psig)

Dimensions (in) (W x D x H)

–40° F

Standard outlet dewpoint:  Standard operating voltage: 

Model

Port Size

Weight (lbs)

120V/1PH/60Hz

0.01µm

Pre-filtration grade:  Post-filtration grade:

CHD-40

40

.75” NPT

300

30x26x63

1µm

CHD-60

60

.75” NPT

360

30x26x67

Standard Standard Standard Optional Standard Optional

Nema 12:

ASME certified vessels:

CHD-80

80

.75” NPT

450

30x26x84

CRN Certified Vessels (80–3000cfm): CRN Certified Vessels (>3000cfm)*:

CHD-100

100

1” NPT

450

30x26x84

cUL & UL control panel:

CHD-125

125

1” NPT

450

30x26x84

CSA control panel:

CHD-150

150

1” NPT

650

34x26x85

40° F/120° F

Min/max inlet air temperature: Min/max operating pressure:

CHD-200

200

1” NPT

650

34x26x85

80 psig/150 psig 15% * Selected provinces only

Average purge air:

CHD-250

250

1.5” NPT

675

39x26x86

CHD-300

300

1.5” NPT

1,250

39x26x86

CHD-400

400

2” NPT

1,250

44x26x87

CHD-500

500

2” NPT

1,250

47x26x88

How to Find Air Flow Capacity

CHD-600

600

2” NPT

2,900

47x26x88

Air flow capacity = Nominal capacity of dryer x Factor F1 x Factor F2 Example: A CHD-500 has a nominal capacity of 500 SCFM. What is the maximum allowable flow through the dryer at following operating conditions? Air Inlet Pressure: 110 PSIG (7.6 BARG)  F1 = 1.04 Air Inlet Temperature: 105° F (40.50° C)  F2 = 0.93 Air flow capacity = 500 x F1 x F2 Air flow capacity = 500 x 1.04 x 0.93 = 483.6 SCFM This is the maximum air flow rate that dryer can accept under those operating conditions. How to Select a Suitable Dryer for a Given Capacity Minimum Std. Air Flow = Design Air Flow / Factor F1 / Factor F2 Example: Given the operating parameters below, find a suitable dryer.

CHD-800

800

3” FLG

2,900

66x40x97

CHD-1000

1,000

3” FLG

3,900

66x40x97

CHD-1250

1,250

3” FLG

3,900

66x40x97

CHD-1500

1,500

3” FLG

4,985

66x40x97

CHD-2000

2,000

4” FLG

4,985

84x59x115

CHD-2500

2,500

4” FLG

7,900

84x59x115

CHD-3000

3,000

6” FLG

7,900

103x70x137

CHD-3500

3,500

6” FLG

9,500

Contact Factory

CHD-4000

4,000

6” FLG

9,500

Contact Factory

CHD-4500

4,500

6” FLG

12,500

Contact Factory

CHD-5000

5,000

6” FLG

12,500

Contact Factory

Capacity Correction Factors for Differing Operating Pressure

Operating Pressure

PSIG 50 60 70 80 90 100 110 120 130 140 150 175 200 225 250

Design Flow Rate: 950 SCFM Inlet Air Pressure: 110 PSIG  Inlet Air Temperature:105° F 

Factor

0.56 0.65 0.74 0.83 0.91 1.00 1.04 1.08 1.12 1.16 1.20 1.29 1.37 1.45 1.52

F1 = 1.04

F2 = 0.93 Minimum Std. Air Flow = 950/1.04/0.93 = 982.22 Therefore the model suitable for the conditions above is CHD-1000.

Capacity Correction Factors for Differing Inlet Air Temperatures

°F

70

80

90

100

105

110

115

120

Factor

1.12

1.10

1.06

1.00

0.93

0.86

0.80

0.75

Clean Resources | 1540 Louis Bork Drive, Batavia, IL 60510 | 800-566-0402 | cleanresources.com

v1.6 8-17-2023

Made with FlippingBook - Share PDF online