INSTALLATION INSTRUCTIONS
Page 2
Manifold & Conversion Kit FOR IDC SERIES 500 — 2000 UNITS
This side contains additional instructions for the installation of a new drum. See the other side for retrofit kit installation steps.
6. Run the outlet hose to a drain. Do not allow air locks, kinks, or excess coil in the outlet hose. The hose MUST lay flat, or the unit will not drain. 7. Prime the unit by removing one of the Exhaust Filters and pouring water into the opening until water drains through the outlet. Not priming the unit will cause premature failure. 8. Connect a 1/4-inch poly tube from any clean shop air source to the push-to-connect fitting on the left side of the timer drain, labeled IN . Plug the timer drain into a 110-volt outlet. 9. Press the TEST button on the timer drain. You should hear a low gurgling sound as the timer drain sends a burst of air into the drum. If you don’t hear the bubbles, check that your power source and air source are turned on and that your poly tubes are connected to the correct IN and OUT fittings on the timer drain.
6
7
10.Connect inlet lines. Remove one red ( 1 ⁄
4 -inch) or
black ( 1 ⁄ 2 -inch) cap for each inlet line. Replace those caps with push-to-connect fittings and hand tighten ONLY. Insert the poly tubes into the push-to-connect fittings.
8
9
11.Scan the QR code to complete warranty registration.
10
11
Questions? Contact your Distributor or Clean Resources: 800-566-0402 • cleanresources.com/contact