SIAL>>> GENERAL SPECIFICATIONS
MEDIUM DENSITY
• Modular connector mixing signal and coax contacts in many arrangements • Lateral displacement capability allowing the use of thermal clamps: ± 0.25 [ ± .010] • Complete range for test, programming and maintenance • Designed for severe mechanical environments • 2.54 [.100] staggered grid (1.27 [.050] offset), 1.905 [.075] between rows
Markets
Main characteristics •
Medium density: 0 14 cts/mm² [90 cts/inch²]
• 13 arrangements on 5 rows of contacts, from 18 to 392 signal contacts • 5 hybrid arrangements mixing coax and signal contacts • 3 A per signal contacts / DWV: 750 Vrms • Lateral rails to protect the male contacts from external damage • Repairable contacts for easy maintenance
Main applications
Recommended configurations
Terminations
Standard
CECC 75101-012
MIL-DTL-55302
A
Plan originel ECHELLE
DESSIN: BOTOMA le
Amphenol Socapex
1,000
TECHNIQUE:
How to order
BP 29 - 74311 THYEZ CEDEX
1/1
A
Plan originel ECHELLE Plan originel ECHELLE
DESSIN: BOTOMA le DESSIN: BOTOMA le
BP 29 - 74311 THYEZ CEDEX BP 29 - 74311 THYEZ CEDEX Amphenol Socapex Amphenol Socapex
A
1,000
TECHNIQUE: TECHNIQUE:
000 001 010 011 100 102 103 200 300 500 502
Standard ASL F or E with 5 right & left coax ASL E with 2 76 MAX mm PCB thickness ASL E with heatshrink sleeve ASL S and E 392 screw locking system ASL F with Y01 contacts without lateral displacement ASL S Y04 straight/flex locking system ASL 39758119 space customer specification ASL MA3401 space customer specification ASL F or E with 5 coax after signal contacts ASL F or E with 5 coax before signal contacts Deviation
1,000
1/1
1/1
A
A
Plan originel ECHELLE Plan originel ECHELLE
DESSIN: BOTOMA le DESSIN: BOTOMA le
Amphenol Socapex
E F T S
Female receptacle
1,000
1,000
TECHNIQUE: TECHNIQUE:
Female receptacle
Size Male plug
BP 29 - 74311 THYEZ CEDEX BP 29 - 74311 THYEZ CEDEX
1/1
1/1
Conductive fitting Standard version For E and F types
Male plug
C
KX NX
KT NT
Size 12 Size 16 No coaxial contact
Female test receptacle
Blank Non conductive fitting Test versions and specifics Conductivity of the fitting
Male test plug Female extender receptacle
Blank
P
Connector type
Coax module
Blank: Tin lead LF: Lead free Termination plating
ASL -
---
---
-
--
---
---
--
Number of coax contacts (see page 93) Size Number of coax
Number of signal contacts (see page 88) Signal contacts only
Signal contacts (see pages 84 to 85) Male contact
Signal & coaxial contacts
Female contact
03 06 09 12 05 10
018 (+3) 058 (+3) 098 (+3) 058 (+5) 156 (+10) 196 (+5) 254 (+5)
156 196 214 254 312 370 392
E
Y09, Y19
018 036 058 076 098 116
12
Y01, Y02, Y04, U04, U05, U06, U07, U08
F
Y01, Y02, Y04, U04, U05, U06, U07, U08 Y01, Y02, Y04, U04, U05, U06, U07, U08
T
16
P
No coaxial contact
Blank
S
Y03 Y02 Y04
All dimensions are given for information only and are in mm [inch], except as otherwise specified