Tactical cables technical information
OCC
NEXANS
SPECTRA STRIP
BRUGG
Company
2
4
6
8
1
2-4
6
8
1 - 2 - 4 - 6 - 8
1
2
4
Number of fibers
5 (0,2) 23 (15)
5,5 (0,22)
6.0 (0,24)
6,5 (0,26)
6 (0,24)
5,4 (0,21)
6,1 (0,24)
6,3 (0,25)
3,4 (0,13)
3,8 (0,15)
3,8 (0,15)
5,5 (0,22)
Cable diameter mm (in)
28 (19)
38 (26)
26 (18)
25 (17)
32 (22)
35 (24)
(2-4 core typically)
25
18 (12)
25 (17)
26 (17)
28 (19)
Cable weight kg/km (lb/1,000ft)
(17)
aramid yarns
aramid yarns
stainless-steel wires
Reinforcing protection
aramid yarns
spectraloy
polyamid
Outside jacket
polyurethan
polyurethan
Multimode 850nm (MHz/km) Multimode 1300nm (MHz/km) Single mode 1310nm (GHz/km) Single mode 1550nm (GHz/km)
200 (50/125) 400 (62,5/125) 400 (50/125) 600 (62,5/125)
500 (50/125) 200 (62,5/125) 800 (50/125) 500 (62,5/125)
500
200 (62,5/125)
500 (62,5/125)
800
Fiber minimum bandwidth
3,5
3,5
-
-
-
18
18
-
Multimode 850nm (dB/km)
3,5
3,5
3 (62,5/125)
2,7
Multimode 1300nm (dB/km) Single mode 1310nm (dB/km) Single mode 1550nm (dB/km)
1,5
1,5
1 (62,5/125)
0,8
Fiber maximal attenuation
0,36
0,45
0,42
-
0,25
0,3
0,28
-
-60 C / +85 C (-76 F / +185 F) -55 C / +85 C (-67 F / +185 F)
-55 C / +85 C (-67 F / +185 F) -60 C / +85 C (-76 F / +185 F)
-70 C / +85 C (-94 F / +185 F) -55 C / +85 C (-67 F / +185 F)
-40 C / +70 C (-40 F / +158 F) -40 C / +70 C (-40 F / +158 F)
Storage
Temperature range
Operating
60 (2,36)
30 (1,18)
35 (1,38)
35 (1,38)
10 X OD cable
Minimum bending radius mm (in)
8 X OD cable
50 (1,97)
(2-4 core typically) (60- 1 part.3 cl.15.1) 2000 (450) (2-4 core typically) 2600 (2-4 core typically) (IEC 60794-1-1 &2) 1200 (685)
Short term N (lbs.f) Operating N (lbs.f)
1800 (405) 600 (135)
1800 (405) 600 (135)
1800 (405) 600 (135)
1800 (405) 600 (135)
(IEC 794 1E1) 2200 (495)
1000 (225) 750 (169)
2500 (562) 1800 (405) 1200 (685)
1600 (360) 1100 (247) 1000 (571)
Maximum tensile strength
30
1300 (292)
2500 (1428)
(EIA 455 41) 440 (251) (EIA 455 25) 200
(IEC 794 1E3) 300 (171) (IEC 794 1E4) 100 (IEC 794 1E8) 30000 cycles
Crush resistance N/cm (lbs/in)
100 min
100 min
Impact resistance (1J impact)
(2-4 core typically) (IEC 60794-1-1) 1000 cycles
10000 min
7000 min
7000 min
(TIA/EIA-455-104) 2000 cycles
Torsion/torque
Technical information given by the supplier
Optical fiber Tactical cables with aramid yarn reinforcing protection Fiber coating Buffer (900 µm)
Aramid yarns Outside jacket
1 - Polyamide jacket Tactical cable with stainless steel wires reinforcing protection 2 - Stainless steel wires
3 - Optical fibres (250 µm) 4 - Stainless steel loose tube
Made with FlippingBook interactive PDF creator