Amphenol Socapex | RNJ RANGE
RNJ LOW PROFILE - RACK & PANEL
Presentation
1 - Receptacle shell 2 - Panel seal 3 - Gasket 4 - Rivet 5 - Socket insert 6 - Socket crimp contact 7 - Interfacial seal 8 - Plug socket 9 - Pin insert 10 - Protection cover
11 - Membrane 12 - Plug shell 13 - Grommet 14 - Compound 15 - Retention disc 16 - TPRS bond 17 - Grounding spring 18 - Pin crimp contact 19 - Wave spring
Online configurator & 3D model download
Plug concept
Metal shell
Pin or socket
Rear membrane for sealing
Grounding spring
Electrical insert
Guiding Pin
Scan me
Panel integration
- Mandatory distance to guarantee the product performances. - Guiding system: the system must ensure the right positioning of the rack independently of the connectors. - No mechanical stress must be applied to the rear of the plug (wires or flex).
Jam nut Panel to panel distance
Square flange Panel to panel distance
+0 -0.5
+0 -0.5
16mm
7.3mm
PLUG RNJLP 26 XX RNJLP 46 XX
PLUG RNJLP 66 XX RNJLP 86 XX
RECEPTACLE RNJLP 27 XX
RECEPTACLE RNJLP 67 XX
Panel mounting direction
Plug
Receptacle
Jam nut RNJLP26/46
Square flange RNJLP66/86
Jam nut RNJLP27
Jam nut stand-off RNJLP27***F459
Square flange RNJLP67
Back panel mounting Front panel mounting
-
-
For other panel mouting directions, please consult us.
Amphenol SOCAPEX
Due to technical modifications, all information provided is subject to change without prior notice Designed by Amphenol Socapex
41