BlueCool A-Series Electric heat module
Air handlers: BlueCool A-Series Flow control valve
Type
EHM600W -100 mm -230 V -50/60 Hz
EHM900W -125 mm -230 V -50/60 Hz
EHM1200W -150 mm -230 V -50/60 Hz
EHM1800W -150 mm -230 V -50/60 Hz
Valve with motor actuator
Kit Motor valve Slimline / Low profile A-Series with 90° elbow
Kit Motor valve Compact A-Series
WBCL1209100B
WBCL1209101B
WBCL1209102B
WBCL1209103B
Order numbers
Order numbers
WBCL151004B
WBCL151003B
600
900
1,200
1,800
Capacity (W)
370 x 100 x 170 14.6 x 3.9 x 6.7
370 x 125 x 195 14.6 x 4.9 x 7.7
370 x 150 x 220 14.6 x 5.9 x 8.7
370 x 150 x 220 14.6 x 5.9 x 8.7
Dimensions (L x W x H) (mm) Dimensions (L x W x H) (inch) Ø Hose connection (mm) Ø Hose connection (inch)
Valve with thermal actuator*
Kit Therm valve Slimline / Low profile A-Series with 90° elbow
Kit Therm valve Compact A-Series
100
125
150
150
4
5
6
6
230 (-15% / +10%)
230 (-15% / +10%)
230 (-15% / +10%)
230 (-15% / +10%)
Voltage (V)
50 / 60 (+-5%)
50 / 60 (+-5%)
50 / 60 (+-5%)
50 / 60 (+-5%)
Frequency (Hz)
Order numbers
2510181A
2510182A
3
4
5
8
Current draw running (A)
* Valves with thermal actuator are suitable for A-Series model from A4 up to A18. Due to their longer activation time they are not suitable to be operated in permanent blower mode.
40 60 60 60
40 60 60 80
40 60 60
40 60 60
Max. supply air temperature (°C) Cut off temperature safety switch (°C)
Pressure loss air (Pa)
120
180
Min. air flow (m³/ h) to ensure full heat output
2.2
2.6
2.8
3
Weight (kg)
Compatibility A4 Compact A6 Compact, Slimline, Low Profile
A9 Compact, Slimline, Low Profile
A12 Compact, Slimline, Low Profile
A18 Compact, Slimline, Low Profile
A24 Compact A36 Compact
EHM600W EHM900W EHM1200W EHM1800W
g
c
c
c
c
c
c
– – –
–
–
g
g
c
c
– –
– –
g
g
g
g
–
–
g
g
g Standard application, check on minimum airflow in technical data. c Only for secondary ducts with smaller diameter, check on minimum airflow in tech - nical data.
Flow control valve for Slimline and Low profile
Flow control valve for Compact
Electric heat modules ensure cabin heating independent of chiller operation They are easily installed in-line into air duct of the A-Series air handlers EHM is directly connected to A-Series electronics so no separate controls are needed EHM further increase the comfort on board by: – enabling heating in selective cabins while chiller is in cooling mode – enable heating while chiller is switched off – increasing the heat output of air handlers if extra high heat demand is needed EHM can easily be retrofitted to existing A-Series EHM is preinsulated to prevent condensation on the outside. It also comes with 2 stainless steel mounting brackets for wall mounting When using EHM a flow control valve also needs to be fitted
The flow control valve acts as a 3 / 2-way valve allowing the chilled water to bypass the heat exchanger of the A-Series when needed Easy screw connection to all A-Series units, no soldering needed Easy electrical connection to A-Series electronics 90° elbows in the Slimline / Low profile kit enable an extra flat installation The flow control further increases the comfort on board by: – directing the chilled water only to those cabins with cooling / heating demand – prevent inadvertent heating when air handler is switched off – no chimney effect – prevents condensate build-up and thus mold on heat exchangers of air handlers which are switched off – continuous blower operation is possible thus reducing noise variations in cabins Valve needs to be fitted if EHM is installed to prevent simultane - ous heating and cooling
H
L
W
EHM – Electric heat module