Water heaters Thermo Pro 90 / Thermo Pro 90 Chiller
Thermo Pro 90 Marine – state-of-the art controller and easy service Experience the advantages of one of our most renowned heating devices! With its high heating output, proven long-term durability, and low cost of ownership it is your perfect choice for small to midsize boats. Thermo Pro 90 Chiller – the heater for integration into an A/C system If you want to build a BlueComfort system with a Thermo 90 heater (see chapter “Integrated solutions“), use the Thermo Pro 90 Chiller version. It comes with a special electronic control unit and without the water pump which is not needed.
1
Scopes of delivery
Order number 9029940C Thermo Pro 90 Marine 12 V Diesel 9029941C Thermo Pro 90 Marine 24 V Diesel 9029942C Thermo Pro 90 Chiller 12 V Diesel 9029943C Thermo Pro 90 Chiller 24 V Diesel
The advantages of the Thermo Pro 90: Stepless variable power adjustment High heat output Compact dimensions Service friendly technology Extremely low noise level Low fuel consumption and low emissions
6
7
18
17
8
22
13
5
21
20
16
4
15
19
2
23
Water system For the distribution of heat in your boat you may need extra hoses, valves, expansion tank, convectors, air handlers etc. Please compose your water system individually. Fuel supply For the installation of the heater in the engine compartment the fuel supply system has to be fire-resistant according to EN ISO 7840. Please order the adequate components additionally (fuel lines, fuel supply kit, rubber hose, fuel pump protection). Exhaust system Depending on the installation position and length of the exhaust pipe you may need a condensation water drain and an exhaust pipe insulation additionally. Control element Please order an adequate control element. For the Thermo Pro 90 Chiller no control element is needed. The heater is activated via the air- conditioning control. Accessories (optional) For extension of your heater system you find comfort control elements as well as other installation and system components in the accessories section.
3
14
11a
12a
11
9
12
ItemQty Description 1 1 Heater 12 or 24 V including coolant
3
pump U4840 and electronic control unit (no coolant pump with Thermo Pro 90 Chiller)
This 44’ sailing yacht uses convectors to heat all cabins separately. Convectors are noiseless and do not consume any electrical power of the battery, giving the yacht improved electrical autonomy.
2 1 Electronic control unit 3 1 Fuel pump DP42.4 4 1 Wiring harness (heater, 570 lg) 5 1 Wiring harness (fuel pump, 5,000 lg) 6 1 Switch with lamp 12 or 24 V (not with 9029942A and 9029943A) 7 1 Fuse holder with wiring harness 8 1 Heater bracket 9 1 T-piece + fuel hoses & hose clamps (8 x 5 x 8) 10 1 Hose Ø 5 x 1.5; 6,000 lg 11 4 Fuel hose Øi 4.5 / Øa 10.5; 50 lg 11a 2 Fuel hose Øi 8 / Øa 12; 70 lg
4
In this 40’ motor yacht electrical fan blowers are used to heat up the boat. T hey are very compact and may be easily installed in small spaces, blowing h ot air through air ducts into each cabin. The windscreen has a separate b lower to demist and defrost.
Technical specifications
Thermo Pro 90
Thermo Pro 90 Chiller
12 8 Hose clamp (steel; Ø 10) 12a 4 Hose clamp (steel; Ø 12) 13 1
EC approval mark ECE R122 (Heating) EC approval mark ECE R10 (EMC)
E1 00 0320 E1 04 6196
E1 00 0320 E1 04 6196
5
Bent hose Øi 20 / Øa 29; 2,200 lg Air intake silencer PAK Øi 30,5 / Øa 38; 1,160 lg
Heating power, control range / boost (kW) Heating power, control range / boost (BTU / h) Fuel consumption, control range / boost (l / h) Fuel consumption, control range / boost (gal / h)
1.8 – 7.6 / 9.1 6,100 – 26,000 / 31,000
1.8 – 7.6 / 9.1 6,100 – 26,000 / 31,000
14 1
0.18 – 1.08 / 1.3 0.05 – 0.24 / 0.34 Diesel DIN EN 590
0.18 – 1.08 / 1.3 0.05 – 0.24 / 0.34 Diesel DIN EN 590
15 1 Exhaust silencer Øa 38 16 1
Flexible pipe (inoxyd.) Øi 38 / Øa 42; 1,600 lg (1 x 1,000 mm + 1 x 600 mm)
Fuels*
Rated voltage (V)
12, 24
12, 24
17 2 Connection pipe Ø 18 x 20 18 2 Connection pipe Ø 20 x 20 19 7 Hose clamp Ø 23 … 35 20 3 Hose clamp Ø 39 … 42 21 2 Pipe clip Ø 42 22 15 Cable tie 178 lg 23 1 Exhaust through hull
20 – 83 / 90 3.0 – 6.9 amps / 7.5 at 12 V, 1.5 – 3.5 / 3.8 at 24 V
Rated power consumption, control range / boost (W) Rated power consumption, control range / boost (amps)
20 – 83 / 90 3.0 – 6.9 amps / 7.5 at 12 V, 1.5 – 3.5 / 3.8 at 24 V
6
Flow rate of coolant pump (against 0.3 bar) (l / h) Flow rate of coolant pump (against 0.3 bar) (gal / min)
700 3.1
– –
Dimensions L x W x H (mm) Dimensions L x W x H (inch)
352 x 131 x 232 13.9 x 5.2 x 9.1
385 x 131 x 219 15.2 x 5.2 x 8.6
Weight (kg) Weight (lbs)
5.3 11.7
4.9 10.8
* Information about further fuels on request.