Water heaters Thermo Top Pro 120 / 150
1
Greater performance and innovation in terms of customer comfort & safety The Thermo Top Pro 120 and Thermo Top Pro 150 constitute a new generation of water heaters in the high-performance categories of 12 and 15 kW. These powerful heaters are each available in 12 and 24 V versions.
Scopes of delivery
Order number 9035585A Thermo Top Pro 120 Basic 12 V Diesel 9035584A Thermo Top Pro 120 Basic 24 V Diesel 9035583A Thermo Top Pro 150 Basic 12 V Diesel 9035582A Thermo Top Pro 150 Basic 24 V Diesel 9042807A Thermo Top Pro 120 Chiller 24 V Diesel
The advantages of the Thermo Top Pro 120/150: Compact design Conventional diesel fuel and 100%
14
13
1
11
10
paraffinic diesel fuel (incl. renewable fuels, such as HVO) ECU and all connections on one side Easy to reach plugs for a fast installation Low noise emission More safety and diagnostic functions New, powerful coolant pump U4850
4
3
15
2
6
5
12
7
16
8
9
Contents scope of delivery/ installation kit Part SOD Basic SOD Chiller IK*
2
Installation kit 9035492A Installation kit 12 V Standard 9035160A Installation kit 24 V Standard
Description
In this 64’ sailing yacht the heater is installed in the technical compartment. Mainly convectors are used as heat exchangers. Fan blowers are only used in cabins with space restrictions or where quick heating up or air circulation is required.
1 2 3 4 5 6
Heater
Coolant pump U4850
Splash guard
3
Bracket coolant pump Mounting material fuel Wiring harness coolant pump Wiring harness vehicle, vehicle fan, fuse holder Exhaust flex pipe** Mounting material ex- haust**
Water system For the distribution of heat in your boat you may need extra hoses, valves, expansion tank, convec- tors, air handlers etc. Please compose your water system individually. Fuel supply Please compose the adequate system components for your boat individually. For the installation of the heater in the engine compartment the fuel supply system has to be fire-resistant according to EN ISO 7840. Exhaust system Please order exhaust hose, the exhaust silencer and skin fitting additionally. Depending on the installation position and length of the exhaust pipe you may need a condensation water drain and an exhaust pipe insulation additionally. Accessories (optional) For extension of your heater system you find comfort control elements as well as other installation and system components in the accessories section.
7
8 9
The heater in this 50’ motor yacht provides heating for both decks. A combination of convectors and fan blowers is used.
4
10 11 12 13 14 15 16
Coolant hose
Mounting material coolant
Fuel hose Fuel filter
Technical specifications
Mounting material fuel filter Mounting material heater Mounting material electric Further mounting material Technical documentation
Thermo Top Pro 120
Thermo Top Pro 150
EC approval mark ECE R122 (Heating) EC approval mark ECE R10 (EMC)
E1 00 0480, E1 00 0481 E1 05 7735
E1 00 0480, E1 00 0481 E1 05 7735
5
Heating power (kW) Heating power (BTU / h) Fuel consumption (l / h) Fuel consumption (gal / h)
12.0 40,950
15.0 51,180
* Only for SOD Basic, not for SOD Chiller ** For marine application additional exhaust system components necessary
1.6 0.42
1.7 0.45
Fuels*
Diesel DIN EN 590
Diesel DIN EN 590
Rated voltage (V)
12, 24
12, 24
100 8.3 amps at 12 V 4.2 amps at 24 V
Rated power consumption (W)
80 6.7 amps at 12 V 3.3 amps at 24 V
6
Flow rate of coolant pump (against 0.56 bar) (l / h) Flow rate of coolant pump (against 0.56 bar) (gal / min)
1,500 6.6
1,500 6.6
Dimensions L x W x H (mm) Dimensions L x W x H (inch)
470 x 200 x 200 18.5 x 7.9 x 7.9
470 x 200 x 200 18.5 x 7.9 x 7.9
Weight (kg) Weight (lbs)
11.7 25.7
11.7 25.7
* Information about further fuels on request.