Webasto Marine Catalog 2024-2025 EN

Hot air system Advantages and features

Hot air system Air flow resistance calculation

Webasto offers a wide range of components for air distribution with high flexibility to fit any application.

To ensure correct application with the correct air distribution system, it is important to have a continuous main line with openings that cannot be closed. The sum of the resistance points of the main line must not exceed the maximum number of resistance points for each air heater model. Lines branching off from the main line are not taken into account. Consequently, the branches can also be designed with closable outlets. In the following table, several air ducting parts are listed. Exceeding the number of points (excessive air resistance of the heating air system) is detected by the heater after starting. For safety reasons, continuous heating operation is then no longer possible and the heater switches to control pause. Air Top 2000 STC: max. 325 resistance points Air Top Evo 40: max. 550 resistance points Air Top Evo 55: max. 375 resistance points 55 / 60 mm inlet 80 / 90 mm inlet Dim. in mm Points Id. Dim. in mm Points Id. Intake grill / grille 60 24 1320163A 90 65 1310581A

The advantages:  Full range of mounting parts needed for any application  Multiple combination possibilities to suit any application  Coloured air outlets, black, white, grey and brown fitting to any interior  Fast and easy installation, also in small spaces  High temperature resistance from -40°C up to +140°C with PA6.6 GF30 glass fibre reinforced synthetic material

Flexible tubing per meter

55

30

various

80

27

various

60

27

various

90

25

various

Additional points for elbow in flexible tube

55

10

various

80

7

various

60

8

various

90

6

various

Air ducting si - lencer

90

24

1321734A

90

16

1320996A

90 > 80

45

1320186A

Reducing adapter air intake

Webasto is not liable for applications made with non-Webasto air ducting parts, especially for parts not guaranteeing high temperature resistance.

Reducing adapter

60 > 55

27

1320127A

80 > 55

223

1319477A

90 > 60

211

1320760A

90 > 80

45

1320185A

90 > 80

45

1320925A

Hose connector

55

12

1319473A

80

5

1319476A

60

10

1320469A

90

5

1319869A

58