AIR CONDITIONING TECHNOLOGY
ELECTRONIC CLIMATE CONTROLLER FOR COOLING CEILINGS, KTRRB SURFACE-MOUNTED INSTALLATION – DESIGN BERLIN 2000
TYPE / IMAGE
ITEM NO.
FEATURES
CIRCUIT DIAGRAM
EURO / PG
KTRRB-052.245
General features: ECO function; ‘heating / cooling / cooling interruption due to condensation / off’ display; ‘sensor break, sensor short-circuit, frost protection’ display; oper- ating mode ‘off with frost protection monitoring’; relative scale; off / comfort / ECO switch External flow sensor (H / C sensor): for automatic switching of the controller to heating or cooling mode depending on the inflow temperature (‘Sensor 2’); alternatively, this input can be used as an H / C changeover contact ECO Contact: upon closing the contact, the ECO function is actuated Forced switch-off contact: external switch-off function with frost protection function Control function: heating and / or cooling, cooling interruption upon condensation of the dew point sensor, frost protection function in the switched-off condition
DA420700
See Page 146
204.10 / I
Control range: 13 to 29 °C Setting range: −8 to +8 °C Neutral zone: approx. 2 K Pipe system compatibility: 2-pipe and 4-pipe
Replacement for KTRRB-040.213
* An internal trimming potentiometer can be used to select whether control should be based on the internal (left stop) or external sensor (right stop). In the interme- diate positions, if both sensors are used, a weighting is applied to the internal room sensor and the external radiation sensor. The weighting allows for compen- sation of different structural conditions such as large window areas or cardinal directions. For very slow controlled systems, it is recommended to assign a higher weighting to the radiation sensor than to the internal room sensor.
Accessories: suitable valve actuators ZBOOA-040.100 (see Page 169), suitable external sensors (‘Sensor 2’); see ‘Sensor technology’.
ACCESSORIES ITEM NO.
FEATURES
EURO / PG
TPS 1
Mounting / attachment: using clips on cooling ceiling capillary pipe Use: drywall cooling ceiling (plasterboard) with hung up capillary pipe mat, metal ceiling cooling ceiling with integrated capillary pipe system
G8000299
63.30 / I
Sensor line extendable up to: 50 m with 2x0.5 mm² Scope of delivery: sensor, 2 clips for cooling pad
Mounting / attachment: using clips on cooling ceiling capillary pipe or cable ties on the pipe Use: pipe systems transporting cold water, plaster cooling ceiling with capillary tube system Sensor line extendable up to: 50 m with 2x0.5 mm² Scope of delivery: sensor, 2 clips for cooling pad, 2 cable ties
TPS 2
G8000300
63.30 / I
Mounting / attachment: attach to pipe by means of cable ties Use: pipe systems transporting cold water Sensor line extendible up to: 50 m with 2x0.5 mm² Scope of delivery: sensor, 2 cable ties
TPS 3
SN120000
56.60 / I
145
Catalogue 2023
Made with FlippingBook Annual report maker