MECHANICAL ROOM HYGROSTATS/ HYGRO-THERMOSTATS, RFSB, FHY, RKKDSB SURFACE-MOUNTED INSTALLATION – DESIGN BERLIN 2000 / 3000 / UP

TYPE / IMAGE

ITEM NO.

FEATURES

CIRCUIT DIAGRAM

EURO / PG

FHY 101.060#21

UA020003

Similar to FHY 101.060#21 but scope of delivery as follows: controller, alre frame ‘Berlin’, 50x50 mm cover, pure white (similar to RAL 9010), glossy

144.00 / I

RFHSB-060.010

General features: External setting Design: Berlin 2000 Surface finish: matt Housing colour: pure white, similar to RAL 9010 Housing material: ABS plastic Operating voltage: no auxiliary energy necessary Ambient temperature: 0 to 60 °C Mounting / attachment: surface / wall mounting (4-hole assembly on flush-mounted socket) Max. switching current: dehumidifying (terminal 4) 5 (0.2) A, humidifying (terminal 2) 2 (0.2) A Switching power: terminal 4: 1150 W, terminal 2: 460 W Switching element: microswitch Switching contact: changeover switch (toggler) Output signal: switching Sensor: plastic fibres Control function: humidifying or de-humidifying

MA020202

85.30 / I

Control range: 35–85% rel. humidity Hysteresis: approx. 7% rel. humidity

RFHSB-060.011

MA020203

Similar to RFHSB-060.010, but with internal setting

76.90 / I

RKDSB-171.000

General features: ‘On / off’ switch; external setting Design: Berlin 3000 Surface finish: matt Housing colour: pure white, similar to RAL 9010 Housing material: ABS plastic Operating voltage: 24 VAC or 230 VAC selectable Ambient temperature: 0 to 50 °C Mounting / attachment: surface / wall-mounting or by means of adapter plate on flush-mounted socket Max. switching current: dehumidifying (terminal 9) 5 (0.2) A, humidifying (terminal 8) 3 (0.2) A, heating (terminal 1) 10 (4) A at 230 VAC / 1 (1) A at 24 VAC, cooling (terminal 2) 5 (2) A at 230 VAC / 1 (1) A at 24 VAC Switching power: terminal 9: 1150 W, terminal 8: 690 W, terminal 1: 2300 W at 230 VAC / 24 W at 24 VAC, terminal 2: 1150 W at 230 VAC / 230 W at 24 VAC Switching element: microswitch (hygrostat) / bimetal (thermostat) Switching contact: 2x changeover switch (toggler) Output signal: switching Sensor: plastic fibres for humidity, bimetal for temperature Control function: humidifying or de-humidifying, heating or cooling Control ranges: Temperature 10 to 35 °C, Humidity 30 to 100% rel. humidity Hysteresis: approx. 4% rel. humidity, approx. 1 K at a temperature change of max. 4 K / h Accessories: adapter plate flush-mounted socket mounting: JZ-17

MA220000

167.50 / I