PRODUCT CATALOGUE 2023 | alre.de

PLANT ENGINEERING

UNIVERSAL CAPILLARY THERMOSTAT RTKSA CAPILLARY SYSTEM – TÜV-TESTED

TECHNICAL DATA

APPLICATION

Colour:

anthracite grey (similar to RAL 7016), front side transparent

This series of devices was specially developed for use in heating technolo- gy; in boiler systems or storage tanks; district heating transfer stations and heat transfer systems; in ventilation technology to monitor supply air or as limiters for electrical heating coils, as well as for controlling and monitoring temperatures in pipelines and tanks. Immersion sleeves, protection coils and mounting sets are not included in the scope of delivery. The JZ-29 mounting set must be used in conjunction with immersion sleeves or protection coils. When used as contact controller (pipe mounting), mounting set JZ-31 must be used, except with models RTKSA-000 100 and RTKSA-001 100.

Sensor material: Sensor length:

Cu

2 m

Max. sensor temperature: Max. head temperature: Permissible atmospheric humidity:

Top scale value +15%

80 °C

Max. 95% rel. humidity, non-condensing

Operating voltage:

none

Max. switching current:

NC contact: 16 (2.5) A at 230 VAC +10% 0.25 A at 230 VDC +10% NO contact TR / TW / STW: 6.3 (2.5) A at 230 VAC +10% 0.25 A at 230 VDC +10% NO contact TB: 2.0 (0.4) A at 230 VAC +10% 0.25 A at 230 VDC +10% Min. 100 mA at 24 V (AC / DC) 230 VAC 50 / 60 Hz, 230 VDC

Min. switching current: Max. switching voltage: Min. switching voltage:

Type testing by TÜV in accordance with DIN EN 14597

24 VAC / 50 Hz, 24 VDC

Switching element: Switching contact:

microswitch

toggler, potential-free heating or cooling

Control range:

Electrical connection: Mounting / attachment:

Push-in terminals

Wall mounting or with optional process connection (immersion sleeve, protection coil or mounting set JZ-31 for pipe mounting)

Protection class: Protection rating:

I

RTKSA-xxx.x0x IP40, RTKSA-xxx.x1x IP54, optional IP65

Safety and EMC:

In accordance with DIN EN 60730 (VDE 0631)

Sensor:

liquid-filled capillary scale: degrees Celsius

General features:

CONTROL RANGE

TYPE

ITEM NO.

HYSTERESIS SENSOR ØXL FEATURES

EURO / PG

RTKSA-000.100

KA000000

0 to 50 °C

1.3 K

6x175 mm

TR, external setting

66.20 / II

RTKSA-000.200

KA000001

0 to 120 °C

3 K

6x87 mm

TR, external setting

67.00 / II

RTKSA-000.300

KA000002

20 to 150 °C

9.1 K

6x56 mm

TR, external setting

67.00 / II

RTKSA-001.100

KA000100

0 to 50 °C

1.3 K

6x175 mm

TW, internal setting

69.40 / II

RTKSA-001.200

KA000101

0 to 120 °C

3 K

6x87 mm

TW, internal setting

69.40 / II

RTKSA-001.300

KA000102

20 to 150 °C

9.1 K

6x56 mm

TW, internal setting

69.40 / II

RTKSA-001.301

KA000103

20 to 150 °C

3.3 K

6x82 mm

TW, internal setting

69.40 / II

RTKSA-002.310

KA000201

20 to 150 °C

– 10 to – 15K*

6x55 mm

TB, internal setting, external reset TB, internal setting, external reset STB, internal setting, external reset

81.10 / II

RTKSA-002.410

KA000200

30 to 110 °C

– 10 to – 15K*

6x72 mm

77.20 / II

RTKSA-003.310

KA000300

20 to 150 °C

– 10 to – 15K*

6x55 mm

94.40 / II

RTKSA-004.310

KA000400

20 to 150 °C

–10 K

6x55 mm

STW, internal setting

86.50 / II

TR = temperature controller, TW = temperature monitor, TB = temperature limiter, STB = safety temperature limiter, STW = safety temperature monitor * Manual reset after cooling down by 10 – 15 K (depending on configured setpoint)

186

Catalogue 2023

Made with FlippingBook Annual report maker