PLANT ENGINEERING
SINGLE-STAGE CAPILLARY THERMOSTATS JET-1
TECHNICAL DATA
APPLICATION
Housing colour:
grey (lower part similar to RAL 7016, upper part similar to RAL 7035) Cu (capillaries made from V2A) 1.8 m (for types with ‘G’ in the type specification: 4.5 m)
Monitoring or control of temperatures of non-aggressive, liquid and gaseous media. Particularly suitable for wall mounting. The SW-200-12 protecting coil is to be used for temperature con- trol of non-aggressive gases in ducts; for temperature control in non-ag- gressive fluids, use the TH immersion sleeve, and in aggressive fluids, the NTH immersion sleeve. Immersion sleeves or protection coils are not a part of the scope of delivery (see ‘Accessories / Miscel- laneous’ section).
Sensor material: Capillary length:
Ambient temperature: Max. sensor temperature: Permissible atmospheric humidity:
−20 to +55 °C
top scale value +15%
Max. 95% rel. humidity, non-condensing
Operating voltage:
none
Max. switching current: Min. switching current: Max. switching voltage: Min. switching voltage: Switching element: Switching contact: Electrical connection: Mounting / attachment:
15 (8) A 150 mA
230 V AC, 50 Hz 24 VAC, 50 Hz
microswitch
toggler, potential-free screw-type terminals
wall mounting
Protection rating: Protection class: Safety and EMC:
IP65
I
according to DIN EN 60730
Sensor:
liquid-filled capillary
General features:
scale: degrees Celsius, mechanical range restriction when external setting is used
TYPE
ITEM NO.
CONTROL RANGE
HYSTERESIS ADJUSTABLE (APPROX.)
SENSOR AXL FEATURES
EURO / PG
JET-110X
JA040100
−35 to +30 °C 2 – 20 K
9.6x122 mm
external setting / TR*
154.10 / II
JET-110XF
JA040200
−35 to +30 °C 2 – 20 K
9.6x122 mm
internal setting / TW*
155.20 / II
JET-120X
JA041100
0 to 60 °C 2 – 20 K
9.6x122 mm
external setting / TR*
154.70 / II
JET-120XG
JA041101
0 to 60 °C 2 – 20 K
9.6x122 mm
external setting / TR*
176.20 / II
JET-120XF
JA041200
0 to 60 °C 2 – 20 K
9.6x122 mm
internal setting / TW*
154.70 / II
JET-130X
JA042100
40 to 100 °C 2 – 20 K
9.6x122 mm
external setting / TR*
154.90 / II
JET-130XG
JA042101
40 to 100 °C 2 – 20 K
9.6x122 mm
external setting / TR*
179.20 / II
JET-130XF
JA042200
40 to 100 °C 2 – 20 K
9.6x122 mm
internal setting / TW*
155.50 / II
JET-133X
JA042300
40 to 100 °C
9.6x122 mm
external setting / TB**
160.30 / II
JET-133XF
JA042400
40 to 100 °C
9.6x122 mm
internal setting / TB**
161.30 / II
JET-140X
JA043100
70 to 130 °C 2 – 20 K
9.6x122 mm
external setting / TR*
158.60 / II
JET-140XF
JA043200
70 to 130 °C 2 – 20 K
9.6x122 mm
internal setting / TW*
159.20 / II
JET-143XF
JA043400
70 to 130 °C
9.6x122 mm
internal setting / TB**
165.10 / II
JET-150
JA044100
100 to 280 °C 8 – 50 K
6x80 mm
external setting / TR*
154.60 / II
JET-150F
JA044200
100 to 280 °C 8 – 50 K
6x80 mm
internal setting / TW*
155.20 / II
JET-153
JA044300
100 to 280 °C
6x80 mm
external setting / TB**
160.30 / II
JET-153F
JA044400
100 to 280 °C
6x80 mm
internal setting / TB**
161.40 / II
TR = temperature controller, TW = temperature monitor, TB = temperature limiter
* Control function heating or cooling ** Control function heating or cooling, locks when temperature rises, manual reset after temperature fall of at least 8 K
ACCESSORIES
Immersion sleeves for types with ‘X’ in the type specification: TH / NTH-140 see Seite 248 Immersion sleeves for types without ‘X’ in the type specification: TH / NTH-100 / 200 / 280 see Seite 248 Protection coil for all types: SW-200-12 see Seite 246
194
Catalogue 2023
Made with FlippingBook Annual report maker