UNIVERSAL PRESSURE SWITCH JPS WITH 2 SWITCHING RANGES

TECHNICAL DATA

APPLICATION

Housing colour and material:

steel plate, grey powder-coated Lower part = steel plate (galv. Zn bl) polyester fabric, coated on both sides

The JPS is a universal pressure switch with two switching ranges and is suitable für oil, water and air. It can also be used as a controller for domestic heating oil supply systems, pressure boosting systems, oil pumps and so on.

Membrane:

Ambient temperature: Medium temperature: Switch-off point: Protection rating: Switching capacity:

max. 55 °C

-30 to +80 °C 0.6 – 2.5 bar

IP10 according to DIN 40050

2A (2) 230 V – in accordance with DIN EN 61058-1

All devices have changeover contacts

Contact:

changeover switch

The starter button causes the second switching range to be bridged (if it functions as a safety range). The red indicator light remains illuminated until the accumulated pressure has reached the first switching range

Pressure ranges (setting ranges) and differentials:

(a) in the normal range: Switching range 1: can be set from 1.0 to 4.0 kp / cm² Differential can be set from 0.7 to 1.5 kp / cm² Switching range 2: can be set from min. 0.3 to max. 1.0 kp / cm² beneath the first range Fixed differential 0.3 kp / cm² (b) with increased pressure range : Switching range 1: can be set from 1.3 to 6.0 kp / cm² Differential can be set from 0.7 to 1.5 kp / cm² Switching range 2: can be set from min. 0.3 to max. 1.0 kp / cm² beneath the first range Fixed differential 1.3 kp / cm²

TYPE ITEM NO.

MEASUREMENT RANGES

FEATURES

EURO / PG

JPS-1

E6160006 2 switching ranges, with starter button and indicator light

Connection adapters for 10-mm immersion sleeve Hexagonal connection-adapters SW17 with 1/4" internal thread Connection adapters for 10-mm immersion sleeve Connection adapters for 10-mm immersion sleeve Hexagonal connection-adapters SW17 with 1/4" internal thread

237.40 / II

JPS-3

E6160020 2 switching ranges, with starter button and indicator light, alternate switch-on point E6160044 2 switching ranges, with starter button and indicator light, alternate switch-on point E6160057 2 switching ranges, with starter button and indicator light, for the higher pressure range

289.00 / II

JPS-3 B

235.60 / II

JPS-4

234.30 / II

JPS-13

E6160119 2 switching ranges, with starter button and indicator light

252.80 / II

SWITCHING POINTS (FACTORY SETTING) JPS TYPE 1

3

3 B

4

13

Lower switch-off point

1.25

1.4

1.3

1.25

0.6

Switch-on point (tolerance / +– 0.02 bar)

1.6

1.8

1.8

1.6

1

Switch-off point (tolerance / +– 0.02 bar)

2.5

2.5

2.9

2.5

2.5