PRODUCT CATALOGUE 2023 | alre.de

NEW

HEATING TECHNOLOGY

ROOM TEMPERATURE CONTROLLER, MECHANICAL, RTBSU FLUSH-MOUNTED INSTALLATION – DESIGN BERLIN UP

TECHNICAL DATA

APPLICATION

Design:

Berlin UP

Control or monitoring of temperatures in closed, dry spaces. Suitable for all heating systems. Valve actuator: normally closed. If normally open heating valves are avail- able, they should be connected to the cooling output of the changeover switch (toggler), e.g., RTBSU-401.010 Up to a maximum of 10 actuators for valves can be connected (normally closed, NC); up to 5 units on the toggler with a NO contact. In terms of visual aesthetics, the basic controllers (RTBSU-401.xxx#00), in com- bination with a 55x55 mm / 70x70 mm cover set, fit perfectly in many switch ranges without the use of an insert frame. The basic controllers (RTBSU-401. xxx#00) in combination with a 50x50 mm cover set fit in nearly all switch ranges with the use of an insert frame.

Housing material:

PA6 plastic 0 to 30 °C

Ambient temperature: Storage temperature: Permissible atmospheric humidity: Electrical connection:

−20 to +70 °C

Max. 95% rel. humidity, non-condensing Spring-loaded terminals (lever actuation type)

Mounting / attachment:

In flush-mounted socket – with suitable cover set, can be adapted to fit virtually any switch range (deep flush-mounted socket recommended)

Protection rating: Protection class:

IP30

II, if properly mounted; with 24 VAC, protection class III

Safety and EMC:

according to DIN EN 60730

Max. power consumption:

< 0.5 W

Switching element:

bimetallic contact

Output signal:

switching

Sensor:

bimetal

Control range: Setting range:

5 to 30 °C 5 to 30 °C

Hysteresis:

approx. 0.5 K at a temperature change of max. 4 K / h

General features:

thermal recirculation; multi-digit display

TYPE / IMAGE

ITEM NO.

FEATURES

CIRCUIT DIAGRAM

EURO / PG

RTBSU-401.000#00 Comparison type: FTR 101.000#00

General features: mechanical range limitation; external setting; protective cap; VDE-tested

UA090000

56.80 / I

Operating voltage: 230 VAC, 50 Hz Max. switching current: 10 (4) A

Max. switching voltage: 230 VAC, 50 Hz Min. switching voltage: 230 VAC, 50 Hz Switching power: 2300 W Switching contact: NC contact (max. 10 actuators) Control function: heating Cover sets are offered in various designs (see the separate overview, ‘alre flush-mounted range (cover sets)’) and are not included in the delivery. Suitable set no.: JZ-001.xxx, (see Page 80, 82) e.g.: 50x50 mm cover set, pure white, glossy: JZ-001.000 55x55 mm cover set, pure white, glossy: JZ-001.100 BUSCH-JAEGER cover set Reflex SI / SI Linear, pure white, glossy: JZ-001.200 / BJ Similar to RTBSU-401.000#00 but scope of delivery as follows: controller, alre frame ‘Berlin’ (neutral), 50x50 mm cover, pure white (similar to RAL 9010), glossy

RTBSU-401.000#21 Comparison type: FTR 101.000#21

UA090014

71.90 / I

74

Catalogue 2023

Made with FlippingBook Annual report maker