CPR • Compliant with 2015 AHA guidelines and ERC guidelines • CPR compressions generate palpable pulse, blood pressure, waveform, and ECG artifacts • Realistic chest compression depth and resistance • Software metrics detects hand placement, rate and depth of compressions, recoil, ventilations, and ventilation to compression ratio IM Medication Administration • Four intramuscular sites Neuro • Tristate pupils • SymEyes (optional) Urinary • Urinary catheterization without fluids • Interchangeable genitalia Vascular Access • Unilateral IV cannulation at antecubital and dorsum of hand • Blood draw with vacuum sealed blood collection system • Unilateral (humoral) IO access • Ultrasound training module insert for IV cannulation (optional) Sounds (Advanced/Complete) • Auscultation of normal and abnormal heart, lung, and bowel sounds with the new StethoSym technology utilizing radio-frequency identification (RFID) tags • Prerecorded speech and vocal sounds • Bidirectional audio communication between manikin and operator 1-year warranty
CAE ARES Ares combines the streamlined simplicity of an emergency care manikin with CAE’s unrivaled modeled patient physiology, offering an entirely new training experience for prehospital and emergency care providers. Ares was created to fulfill the requirements for advanced life support training (ACLS) and emergency care management.
Articulation • Realistic articulation
• Range of motion in hips, knees, ankles, and shoulders • Cervical motion for practice of patient stabilization Airway • Bag-valve-mask (BVM) ventilation • Orotracheal and nasotracheal intubation • Placement of various airway adjuncts • Endotracheal tube intubation • Retrograde and Fiberoptic intubation • Transtracheal jet ventilation • Needle and surgical cricothyrotomy • Tracheostomy • Right main stem intubation with detection • Stomach distention with esophageal intubation • Laryngospasm (manual) Breathing • Spontaneous breathing • Bilateral and unilateral chest rise and fall • Lung auscultation sites on anterior chest • Upper airway sounds: stridor and gurgling • Bilateral needle decompression Cardiac • 4-lead ECG monitoring with real equipment • 12-lead dynamic ECG display • Defibrillation, cardioversion, and pacing using live equipment via external defib box (optional) Circulation • Unilateral blood pressure measurement by auscultation and palpation
#51-162 #51-163 #51-164
Ares Base
Ares Advanced Ares Complete
• Bilateral carotid and femoral pulses • Unilateral radial and brachial pulses • Variable pulse strength
33
*Check website for updated stock information.
Made with FlippingBook - Share PDF online