DPI-IFU DentaPure Intl Cartridge IFU Rev D

FR DE EN ES IT JA PT

DentaPure ™ Cartridge Microbiological Dental Water Purification Cartridge Instructions for Use Use on dental waterlines attached to dynamic instruments. Not for general consumption. Meets water quality having ≤10 CFU/mL.

person. Refer to product label when calling doctor. HAZARDS TO HUMANS : Causes eye irritation. Avoid contact with eyes, skin and clothing. Wear eyewear and gloves. Wash with soap and water after handling. Wash contaminated clothing before reuse. DIRECTIONS FOR USE : Remove end caps. Shocking recommended before installation. Never shock through functional/depleted cartridge. Post installation, use tem - porary section of tubing: shock lines, remove temporary tubing, reinstall functional cartridge. Block/disconnect unused or extra waterlines. Disconnection of water heat - ers recommended. Set water pressure between 40-50 psi. Leave cartridge in place when unit unused. For extended period of non-use protocol, contact Crosstex. Maintain iodine levels with 2-minute morning flush of every line on days patients are seen. Bottle use: Recommend to empty water nightly. Dry upside down or return to manifold. Fol - low bottle manufacturer cleaning protocol. Best practice: wipe down cartridge with clean, dry paper towel, inspect intake end for obstruction. If bottle has protective enclo - sure, omit step. Fill with potable water each morning. If water usage tracked, start new sheet. Iodine Test strips can help to verify performance near end of cartridge life. Maintain continuous iodine presence by installing new cartridge after removing depleted cartridge. Follow wa - terline testing guidance.

Active Ingredient: Iodine*

46% 54%

Other Ingredients

TOTAL

100%

*Bonded to a strong base anion exchange resin

PROFESSIONAL USE ONLY Keep Out Of Reach Of Children

CAUTION : Accidental exposure: If exposure to res - in pellets, use caution. Oral cavity exposure, remove resin with evacuation tip. Oral exposure has not been shown to pose significant health risk. FIRST AID : IF IN EYES : Hold eye open, rinse with water, 15 -20 min - utes. Remove contact lenses after 5 minutes, continue rinsing. Call doctor for treatment advice. ON SKIN/ CLOTHING : Remove contaminated clothing. Rinse skin with water, 15 - 20 minutes. IF SWALLOWED : Call doctor. Sip water if able. Do not induce vomiting unless advised by doctor. Nothing by mouth to unconscious

Suggested Use Table:

DentaPure Cartridge

Water Usage Tracked Water Usage Not Tracked Iodine Content Monitored

DPI365B DPI365M

Change when iodine output falls below 0.5ppm

240 Liters

365 Calendar Days

If temporarily cartridge removal needed, place in a zip top bag labeled and dated with installation date and operatory number/name. Store at room temperature until returned to manifold. DISPOSAL : wrap paper toweling and discard in trash.

Scan for installation instructions

QR Code FPO

US

Crosstex International, Inc. 6789 W. Henrietta Road Rush, NY 14543 USA

Hu-Friedy Europe LLC & Co. KG

STERIS Solutions Limited Chancery House, Rayns Way Watermead Business Park, Syston Leicester, LE7 1PF United Kingdom

STERIS GmbH c/o BDO AG,

Bogenstrasse 6 - 8 78576 Emmingen - Liptingen Germany

Längfeldweg 116A, CH-2504 Biel-Bienne, Switzerland

DPI-IFU-EN / REV D - 05/2024 In case of any serious incident that has occurred and involves our devices within the European Union, please report it to Hu-Friedy Mfg. Co., LLC and your national competent authority of the member state. All company and product names are trademarks of Hu-Friedy Mfg. Co., LLC, its affiliates or related companies, unless otherwise noted. ©2024 Hu-Friedy Mfg. Co., LLC

Page 1

www.hufriedygroup.eu

Made with FlippingBook Annual report