Product Datasheet

Cementitious premium levelling compound

UZIN NC 170 LEVELSTAR

Self smoothing compound with high load-capacity for all floor coverings and wood flooring without any limiation in thickness

MAIN APPLICATION FIELD:

smoothing and levelling of substrates for the subsequent installation of all types of floor coverings u no thickness limitation u

0761 Uzin Utz SE Dieselstrasse 3 89079 Ulm 17

01/01/0065.01 EN 13813:2002 Cementitious levelling compound for substrates in interior locations EN 13813: CT-C40-F7 Reaction to fire A2fl-s1 Release of corrosive substances CT Compressive strength C40 Flexural strength F7

SUITABLE ON / FOR:

calcium sulphate or cementitious screeds, concrete u old screeds or concrete, which may contain old com­ pounds and adhesive residues u existing and new P4 - P7 or OSB 2 - OSB 4 boards, screwed u existing ceramic and natural stone coverings, terrazzo or similar u magnesia and xylolite screeds u precast screeds, screed boards u warm water underfloor heating systems u exposure to castor wheels in accordance with DIN EN 12 529 from 1 mm thickness u suitable for residential, commercial and industrial areas, e.g. hospitals, busy shopping malls, industrial areas, etc. u

PRODUCT BENEFITS/FEATURES: UZIN NC 170 LevelStar is a high-performance smoothing and levelling compound with excellent flow properties. It is fast drying, even with unfavourable climatic conditions. Many types of floor coverings can be installed af­ ter 6 hours*. Offers a fast and secure installation. For interior use. excellent flow characteristics u ready to accept floor coverings after 6 hours* u very high strength u very smooth surface u TECHNICAL DATA: Packaging paper bag, Big Bag (on request) Pack size 25 kg, 1000 kg Shelf life min. 9 months Water quantity approx. 6.5 litres per 25 kg bag Color grey Consumption approx. 1,5 kg/m²/mm thickness Ideal application temperature 15 - 25 °C Working time 20 - 30 minutes* Ready for foot traffic after 1.5 - 2 hours* Ready for covering after approx. 6 hours* Minimum application temperature 10 °C at ground level Flow spread ring approx. 150 mm ± 5 mm Fire reaction A2 fl -1 acc. to DIN EN 13 501-1 *At 20 °C and 65% relative humiditiy and max. thickness of 5 mm. See "Ready for covering".

UZIN | A brand of UZIN UTZ DE | Uzin Utz SE | Dieselstrasse 3 | 89079 Ulm | Telephone +49 731 4097-0 | Fax +49 731 4097-110 | E-Mail info@uzin.de | Internet www.uzin.de

UZIN NC 170 LEVELSTAR

SUBSTRATE PREPARATION: The substrate must be sound, load-bearing, dry, free from cracks and free from materials (dirt, oil, grease) that would impair adhesion. Cement and calcium sulphate screeds must be abraded and vacuumed. Test the substrate in ac­ cordance with applicable standard or notices and report any deficiencies. Any adhesion-reducing or unstable layers, e.g. release agents, loose adhesives, compounds, covering or paint residues, etc. must be removed, e.g. by brushing, abrading, grinding or shot-blasting. Thoroughly vacuum loose material and dust. Use a suitable primer from the UZIN Product Guide according to the type and condition of the substrate. Allow any primer that is applied to dry completely. The datasheets for other used products have to be ob­ served.

READY FOR COVERING: Vorgesehener Oberbelag

Schichtdicke Belegreif

Textile and resilient floor coverings (e.g. PVC, linoleum, rubber), ceramic tiles and natural stone Textile and resilient floor coverings with Sigan 1 or Sigan Elements Plus + Planus Wood flooring; floor coverings in combination with UZIN KE 68

3 mm approx. 6 hours*

5 mm approx. 6 hours* 10 mm approx. 24 hours* 20 mm approx. 48 hours*

3 mm apply Planus soonest after 12 hours*

APPLICATION:

3 mm approx. 15 hours*

1. Put 6.5 litres of cold, clear water into a clean container. Sprinkle in the contents of the bag (25 kg) while mixing vigorously until a smooth and lump-free compound is ob­ tained. Use a mixing device fitted with a UZIN Mixing Paddle. 2. Pour the compound onto the substrate and spread even­ ly with a smoothing trowel or a screed rake. The flow and surface can be improved by removing air using a spike roller. If possible, apply to the desired thickness in one coat.

5 mm approx. 15 hours* 10 mm approx. 24 hours* 20 mm approx. 72 hours* 3 mm approx 15 hours**

Textile and resilient floor coverings

*Ready for covering: At 20 °C and 65% relative humidity. **At 10 °C and 80% relative humidity.

CONSUMPTION INFORMATION: Schichtdicke

Verbrauch ca. 1.5 kg/m² 4.5 kg/m² 15.0 kg/m²

Gebinde / Reichweite

IMPORTANT NOTES:

1 mm 3 mm

25 kg / 16.6 m² 25 kg / 5.5 m² 25 kg / 1.6 m²

A shelf life of 9 months when stored in dry conditions, in the original packaging. The setting and drying times may become longer if the storage time is prolonged. The properties of the cured material are not affected. Care­ fully and tightly reseal opened packaging and use the contents as quickly as possible. u Best applied between 15 - 25 °C and relative humidity below 65%. Low temperatures, high humidity, little air circulation, dense substrates and large thickness will de­ lay the setting and drying time. Whilst high temperatures and low humidity, strong air circulation and absorbent substrates will accelerate setting, drying and readiness for covering. In summer, store in cool conditions and use cold water. u Expansion, movement and perimeter joints in the sub­ strate must be reflected through to the surface. Fit UZIN Foam Expansion Strips to any adjacent, vertical struc­ tures to prevent the ingress of the compound into the joints. u Can be pumped with continuous, forced-action mixer- pumps, e.g. from manufacturers such as m-tec, P.F.T. and others. u The substructure of wooden floors must be dry to pre­ vent damage due to damp through rotting or mould for­ mation. Adequate ventilation or rear-ventilation must be provided especially when installing impermeable floor­ ing, e.g. by removing the existing expansion strip or by installing special skirting with vent openings. u

10 mm

EXTENSION: Schichtdicke

Ideales Streckgut und Zugabemenge 30% quartz sand 0.8 (7.5 kg sand / 25 kg powder)

20 - 50 mm

Depending on the type of sand and the thickness, the water amount may be adapted.

The above information is based on our experience and careful investigations. The variety of associated materials and different constructions and working conditions cannot be individually checked or influenced by us. The quality of your work depends, therefore, on your own professional judgement and product usage. If in doubt, conduct a small test or obtain technical advice. Observe the installation recommendations of the floor covering manufacturer. The publication of this Product Data Sheet invalidates all previous product information. The respective updated version of this datasheet can be found on our website under www.uzin.com | 02/2023

UZIN NC 170 LEVELSTAR

Minimum thickness for resistance of castors is 1 mm. On non-absorbent substrates such as old screeds with closed, fixed, waterproof adhesive residues, a thickness of 2 - 3 mm must be used. u When applying in several coats, allow the compound to dry completely. Then apply UZIN PE 360 PLUS as a in­ termediate primer and leave to dry, before applying sub­ sequent coats. u The minimum thickness below wood flooring is 2 mm. Pay particular attention to a sufficient drying of the level­ ling compound prior to installation of wood flooring. u For thicknesses above 10 mm and on moisture-sensitive substrates, use epoxy primers, such as UZIN PE 460, gritted. u On weak, older substrates with several layers of adhe­ sive or levelling compound, the use of gypsum-based levelling compounds such as UZIN NC 110, UZIN NC 112 BiTurbo or UZIN NC 115 is preferred. u For mastic asphalt screeds gypsum-based levelling compounds such as UZIN NC 110, UZIN NC 112 Turbo or UZIN NC 115 should be used. u The maximum thickness on OSB and chipboards is 3 mm. u Do not use in exterior or wet areas. u Protect freshly applied areas from draughts, direct sun­ light and sources of heat. Cement-based compounds tend to form cracks on soft or tacky substrates. These soft and tacky layers must therefore be removed as much as possible before applying the compound. Leav­ ing such compounds open for too long also promotes such cracking and should therefore be avoided. u Do not use as a screed or as a wear surface, a surface covering must always be applied. u UZIN NC 170 LevelStar has the approval as shipbuilding equipment product by the maritime occupational associ­ ation “See-Berufsgenossenschaft Hamburg”, module B and module D. Certificates are available upon request. The permissible thickness is 20 mm. USCG-No. for the system is 164.106/EC0736/113.113. u Compounds must not enter between insulation and heating pipes because of the risk of corrosion. This ap­ plies in particular for heating pipes made from galva­ nized steel. Insulation may only be cut off after smooth­ ing. u Follow the generally acknowledged rules of the trade and technology for the installation of wood flooring and floor covering in respective of the applicable national standards (e.g. EN, DIN, OE, SIA, etc.) u

PROTECTION OF THE WORKPLACE AND THE ENVIRONMENT: Contains cement low in chromate acc. Regulation (EC) No 1907/2006 (REACH). Keep out of reach of children! Keep children away from fresh product / installation material. Store in a dry and cool place. Once opened, immediately close packaging tightly. Wear nitrile impregnated cotton- gloves and long trousers. During mixing wear a suitable dust-mask and goggles. Thorough ventilation must be en­ sured during and after the installation and drying time of the product. Drinking, eating and smoking are prohibited during the installation. In case of eye contact, wash immediately with plenty of water and seek medical attention. Avoid pro­ longed skin contact with the product. After skin contact thor­ oughly rinse with water immediately.The longer the freshly mixed product remains on the skin, the greater the risk of serious skin damage. Do not allow dispersal into drains, sewers or ground. Rinse tools with water and soap immedi­ ately after use. Presents no physiological or ecological risk when fully cured. Basic prerequisites for best possible in­ door air quality following floor covering work are conformity to standards of the working conditions, as well as thorough­ ly dry substrate, primer and smoothing compound. For aller­ gy information, call +49 731 4097-0 (Germany). DISPOSAL: Where possible, collect product residues and re-use. Do not allow to get into drains, sewers or ground. Empty paper packaging is recyclable. Collect waste product, mix with wa­ ter, allow to harden, then dispose as Construction Waste.

SEALS OF QUALITY & ECOLABELS:

COMPOSITION: Special cements, mineral aggregates, redispersible poly­ mers, high-performance liquefiers and additives. Low chromate content acc. Regulation (EC) No. 1907/2006 (REACH) u EMICODE EC 1 PLUS / Very low-emission u DE-UZ 113 / Environmentally friendly because of low emissions u

The above information is based on our experience and careful investigations. The variety of associated materials and different constructions and working conditions cannot be individually checked or influenced by us. The quality of your work depends, therefore, on your own professional judgement and product usage. If in doubt, conduct a small test or obtain technical advice. Observe the installation recommendations of the floor covering manufacturer. The publication of this Product Data Sheet invalidates all previous product information. The respective updated version of this datasheet can be found on our website under www.uzin.com | 02/2023