Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com
GENERAL NOTES
1 A202 ____
2 A301
1.
THIS DRAWING DEPICTS THE ARCHITECTURAL (SPACE LAYOUT, FURNISHING, FLOOR, WALLS, ROOFS, FOUNDATION, WINDOWS AND DOORS) SYSTEMS. IT PROVIDES A VISUAL REPRESENTATION OF THE ARCHITECTURAL LAYOUT AND COMPONENTS. THE ARCHITECTURAL DRAWINGS ARE PREPARED TO MEET THE SPECIFIC REQUIREMENTS OF THE BUILDING, AS PER THE PROJECT SPECIFICATIONS AND APPLICABLE CODES AND STANDARDS. THE CONSTRUCTION OF THIS HOME SHALL COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL RESIDENTIAL CODE (IRC), INTERNATIONAL MECHANICAL CODE (IMC), THE INTERNATIONAL PLUMBING STANDARD, THE NATIONAL ELECTRICAL STANDARD AND ALL OTHER APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND REGULATIONS. COORDINATION WITH OTHER TRADES HAS BEEN DONE ON A DESIGN LEVEL. THIS DRAWING SHALL BE READ TOGETHER WITH THE ME, EL AND PL DESIGN DRAWINGS TO ENSURE PROPER CONSTRUCTION AND INTEGRATION OF THE BUILDING SYSTEMS.
2. 3.
AA, Ethiopia Info@housedocs.store www.housedocs.store
4.
KEY PLAN
ABOUT WALLS:
1. SHOWER WALL COVERING BATHTUB AND SHOWER SPACES (WALLS AND FLOORS) WITH INSTALLED SHOWER HEADS AND IN SHOWER COMPARTMENTS SHALL BE FINISHED WITH A NON-ABSORBENT SURFACE. WALL PAINT (INTERNAL) THE TYPICAL THICKNESS OF LATEX WALL PAINT IS 1/32 OF AN INCH FOR A SINGLE COAT. AND DOUBLE COAT (1/16") SHALL BE APPLIED FOR DURABILITY. ADHESIVES: THE ADVISABLE TYPE OF ADHESIVE FOR THIS PROJECT IS EPOXY ADHESIVES EPOXY ADHESIVES BECAUSE THEY ARE KNOWN FOR THEIR HIGH STRENGTH, DURABILITY, AND RESISTANCE TO MOISTURE, CHEMICALS AND HEAT. REFER TO SHEETS A201 & A202 FOR GENERAL NOTES ON EXTERNAL FINISHING MATERIALS 2. 3. 1. 2. 3. 4. 5. 6. 7. ABOUT FLOORS: THE SPOT ELEVATION INDICATES THE FINISHED FLOOR ELEVATION. FINISHED FLOORS PER PLANS. FIELD VERIFY FOR DIMENSION DROP 4" FOR SHOWER AND BATHTUB USE. 1% SLOPE ON OUTDOOR BALCONIES FOR WATER RUN OFF. 2% SLOPE TOWARDS THE SHOWER DRAIN FOR SUFFICIENT DRAINAGE. 4" DROP AT THE DOOR LEADING TO EXTERIOR BALCONY FROM THE MAIN LIVING AREA. 5% SLOPE FOR GARAGE IS USED, WHICH SHOULD BE CHECKED WITH THE LOCAL GARAGING ZONING LAWS.
1
6
6
02
02
NO.
DESCRIPTION
DATE
100 SF BEDROOM 2
113 SF BEDROOM 3
11 SF CL 2
135 SF KITCHEN
5
4
5 SF CL 3
3
3
41 SF BATH 2
NOTE:
2
47 SF HALL
6
2
3
14 SF W/D
1 A301
1 A301
11 SF CL 1
LEGEND:
294 SF LIVING ROOM
2 A201 ____
175 SF BEDROOM 1
2 A202 ____
FURNITURE SCHEDULE
2
TYPE MARK
TYPE
COUNT
05
04
03
01
01 02 03 04 05
KING SIZE BED DOUBLE BED
1 2 1 2 1
41 SF BATH 1
0' - 2"
THREE SEAT SOFA TWO SEAT SOFA COFFEE_TABLE
PROJECT
04
2
21 SF W/C
IMMENSE-550
ROOM FINISH SCHEDULE
1
4
ROOM NUMBE
COM MEN TS
FLOOR FINISH
BASE FINISH
CEILING FINISH
CEILING HEIGHT
3
2
R ROOM NAME
WALL FINISH
DRAWING NAME
01 02 03 04 05 06 07 08 09 10 11 12 13
LIVING ROOM HARDWOOD CONCRETE WALL PAINT
DRY WALL 8' - 0"
KITCHEN
HARDWOOD CONCRETE WALL PAINT + CERAMIC DRY WALL 8' - 0"
FLOOR PLAN
BEDROOM 1 BEDROOM 2 BEDROOM 3
HARDWOOD CONCRETE WALL PAINT HARDWOOD CONCRETE WALL PAINT HARDWOOD CONCRETE WALL PAINT VINYL TILES CONCRETE CERAMIC TILE VINYL TILES CONCRETE CERAMIC TILE HARDWOOD CONCRETE WALL PAINT HARDWOOD CONCRETE WALL PAINT HARDWOOD CONCRETE WALL PAINT HARDWOOD CONCRETE WALL PAINT HARDWOOD CONCRETE WALL PAINT HARDWOOD CONCRETE CERAMIC TILE
DRY WALL 8' - 0" DRY WALL 8' - 0" DRY WALL 8' - 0"
BATH 1 BATH 2
MRD MRD
8' - 0" 8' - 0"
CL 1 CL 2 CL 3 W/C HALL
DRY WALL 8' - 0" DRY WALL 8' - 0" DRY WALL 8' - 0" DRY WALL 8' - 0" DRY WALL 8' - 0" DRY WALL 8' - 0"
Client Name 0061_12
DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:
3/8" = 1'-0" 1 FLOOR PLAN
2 A301
8/14/2025 11:21:24 AM
1 A201 ____
Designer
W/D
housedocs.store
CHECKED BY: DRAWN BY:
Checker
A101
SQUARE FOOTAGE
LIVING
1183
TOTAL
1183
SCALE:
As indicated
© [2024] [FrameUpNow] . All rights reserved