HVAC Color scheme
air conditioning pipe line
Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com
GENERAL NOTES
1. THIS DRAWING DEPICTS THE HVAC (HEATING, VENTILATION, AND AIR CONDITIONING) SYSTEM FOR THE IMMENSE _STAN_HUFF. IT PROVIDES A VISUAL REPRESENTATION OF THE SYSTEM LAYOUT AND COMPONENTS. 2.THE HVAC SYSTEM IS DESIGNED TO MEET THE SPECIFIC REQUIREMENTS OF THE BUILDING, INCLUDING HEATING, COOLING, AND VENTILATION NEEDS, AS PER THE PROJECT SPECIFICATIONS AND APPLICABLE CODES AND STANDARDS. 3. THE HVAC SYSTEM INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL MECHANICAL CODE (IMC), INTERNATIONAL RESIDENTIAL CODE (IRC), AND ALL OTHER APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND REGULATIONS. 4. THE EQUIPMENT SHOWN ON THIS DRAWING INCLUDES BUT IS NOT LIMITED TO AIR HANDLING UNITS (AHUS), CHILLERS, BOILERS, COOLING TOWERS, PUMPS, DUCTWORK, DIFFUSERS, GRILLES, AND CONTROL DEVICES. 5. ALL EQUIPMENT, DUCTWORK, AND PIPING SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, LOCAL CODES, AND INDUSTRY BEST PRACTICES. 6. ALL DUCTWORK SHALL BE SIZED, FABRICATED, AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE ACCA MANUAL D AND THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS. DUCTWORK SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PROPERLY SUPPORTED AND BRACED TO PREVENT SAGGING, AIR LEAKAGE, OR VIBRATION. 7. CONDENSATE DRAINAGE PIPING SHALL BE PROPERLY PITCHED TO ENSURE POSITIVE DRAINAGE TO AN APPROVED DISPOSAL LOCATION, SUCH AS A FLOOR DRAIN, SUMP PUMP, OR EXTERIOR GRADE. CONDENSATE LINES SHALL BE INSULATED TO PREVENT SWEATING. 8. THE LOCATION OF CONTROL PANELS AND SENSORS INDICATED ON THIS DRAWING CAN BE MODIFIEDwith THE SPECIFIC LOCATIONS AND WIRING DETAILS WILL BE DETERMINED DURING THE CONTROL SYSTEM DESIGN AND INSTALLATION. 9. THE HVAC SYSTEM DESIGN CONSIDER ENERGY EFFICIENCY, INDOOR AIR QUALITY, OCCUPANT COMFORT, AND NOISE CONTROL, FOLLOWING APPLICABLE GUIDELINES AND REGULATIONS. 10. COORDINATION WITH OTHER TREADS HAS BEEN DONE ON A DESIGN LEVEL. THIS DRAWING SHALL BE READ TOGETHER WITH THE AR, EL AND SN DESIGN DRAWINGS TO ENSURE PROPER INSTALLATION AND INTEGRATION OF THE HVAC SYSTEMS. 11. THE HVAC CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND LICENSES, AND FOR SCHEDULING AND COORDINATING WITH THE LOCAL BUILDING DEPARTMENT AND UTILITY PROVIDERS TO ENSURE A TIMELY AND COMPLIANT INSTALLATION. 12. ALL DUCTWORK PENETRATIONS THROUGH WALLS, FLOORS, OR CEILINGS SHALL BE PROPERLY SEALED AND FIRE-STOPPED USING APPROVED METHODS AND MATERIALS TO MAINTAIN THE INTEGRITY OF THE BUILDING'S FIRE-RESISTANCE RATINGS. 13. HVAC EQUIPMENT SHALL BE INSTALLED LEVEL AND PLUMB, AND IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS. PROVIDE ADEQUATE CLEARANCES AROUND EQUIPMENT FOR PROPER AIRFLOW, SERVICE ACCESS, AND CODE COMPLIANCE. 14. ALL HVAC EQUIPMENT AND COMPONENTS, INCLUDING THERMOSTATS, DAMPERS, AND ACCESS PANELS, SHALL BE LOCATED IN ACCESSIBLE AREAS FOR EASY SERVICING AND MAINTENANCE. PROVIDE ADEQUATE SPACE AROUND EQUIPMENT FOR PROPER AIRFLOW AND SERVICE ACCESS. 15. THE HVAC SYSTEM SHALL BE BALANCED AND ADJUSTED TO ENSURE PROPER AIRFLOW, TEMPERATURE DISTRIBUTION, AND SYSTEM PERFORMANCE THROUGHOUT THE RESIDENCE. PROVIDE A WRITTEN REPORT DOCUMENTING THE FINAL SYSTEM BALANCE. 16. ANY DEVIATIONS OR MODIFICATIONS TO THE HVAC SYSTEM DESIGN SHALL BE REVIEWED AND APPROVED BY THE RESPONSIBLE DESIGN PROFESSIONALS AND COMMUNICATED TO ALL RELEVANT PARTIES INVOLVED IN THE CONSTRUCTION PROCESS. 17. FOR ANY INQUIRIES OR CLARIFICATIONS REGARDING THE HVAC SYSTEM DESIGN, PLEASE CONSULT THE RESPONSIBLE DESIGN PROFESSIONALS OR THE PROJECT MANAGEMENT TEAM.
AA, Ethiopia Info@housedocs.store www.housedocs.store
KEY PLAN
∅ 3/4"
AIR HANDLING UNIT
AIR HANDLING UNIT
Hood-Wall
Condenser
NO.
DESCRIPTION
DATE
∅ 3/4"
EXHAUST FAN
∅ 3/4"
NOTE:
∅ 3/4"
AIR HANDLING UNIT
SYMBOLS
VAINED ELBOW; TYPICAL AT ALL SQUARE AND RECTANGULAR ELBOWS
SUPPLY DIFFUSER
LEGEND:
EXHAUST FAN
VAINED ELBOW; SHORT RADIUS
∅
3/4"
∅ 3/4"
STANDARD RADIUS ELBOW
RETURN DIFFUSER
6' - 8"
3' - 2 1/2"
3' - 2 1/2"
Supply DUCT
AIR HANDLING UNIT
RETURN DUCT
EXHAUST DIFFUSER
PROJECT
IMMENSE-550
3/8" = 1'-0" 1 HVAC PLAN
Air handling unit
SIDEWALL SUPPLY DIFFUSER
FLEXIBLE CONNECTION
transition
MECHANICAL EQUIPMENT SCHEDULE
REFRIGERANT LINE SCHEDULE
FC
DRAWING NAME
ELEVATION INCLINE - RISE; IN DIRECTION OF FLOW ELEVATION INCLINE - DROP; IN DIRECTION OF FLOW
CATAGORY
DESCRIPTION
COUNT
CATAGORY
DESCRIPTION
DIAMETER
LENGTH
R
HVAC PLAN
Air condenser
AIR HANDLING UNIT AIR HANDLING UNIT: WALL MOUNTED
4 1 2 1
Pipe Types Pipe Types Pipe Types Pipe Types
Copper Copper Copper Copper
1/4" 3/8" 1/2" 3/4"
0.66
D
CONDENSER Exhaust Fan RANGE HOOD
Condenser: OUT DOOR EXHAUST FAN: 75 CFM
67.08
0.69
Hood-Wall: VENT
112.37
DUCT hanger
CONNECT NEW DUCT TO EXISTING DUCT
E
N
DUCT FITTING SCHEDULE
Owner 15_0001
DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:
REFRIGERANT LINE FITTING SCHEDULE
CATAGORY
DESCRIPTION
COUNT
CATAGORY
DESCRIPTION
Size
Count
Round Transition - Angle
45 Degree
5
8/5/2025 1:10:30 AM
Designer
Elbow - Generic
Elbow - Generic: Standard/HVAC Elbow - Generic: Standard/HVAC Elbow - Generic: Standard/HVAC Elbow - Generic: Standard/HVAC
1/2"ø-1/2"ø 1
FLEX DUCT SCHEDULE
housedocs.store
CHECKED BY: DRAWN BY:
Elbow - Generic
1/4"ø-1/4"ø 1
DESCRIPTION DESCRIPTION
LENGTH
DIAMETER COUNT
Checker
Elbow - Generic
3/4"ø-3/4"ø 29
Flex Duct Round FLEX-ROUND
15.062 15.062
4"
4
Elbow - Generic
3/8"ø-3/8"ø 21
Grand total: 4
Tee - Generic
Tee - Generic: Standard
3/4"ø-3/4"ø-3/ 4"ø 3/8"ø-3/8"ø-3/ 8"ø
3
M101
DUCT ACCESSORY SCHEDULE
Tee - Generic
Tee - Generic: Standard
3
CATAGORY
DESCRIPTION
COUNT
Transition - Generic Transition - Generic
Transition - Generic: Standard 3/4"ø-1/2"ø 9 Transition - Generic: Standard 3/8"ø-1/4"ø 1
ROOF VENT
3'' DIAMETER
4
SCALE:
As indicated
© [2024] [FrameUpNow] . All rights reserved