GENERAL NOTES

1. THIS DRAWING DEPICTS THE HVAC (HEATING, VENTILATION, AND AIR CONDITIONING) SYSTEM FOR THE IMMENSE _STAN_HUFF. IT PROVIDES A VISUAL REPRESENTATION OF THE SYSTEM LAYOUT AND COMPONENTS. 2.THE HVAC SYSTEM IS DESIGNED TO MEET THE SPECIFIC REQUIREMENTS OF THE BUILDING, INCLUDING HEATING, COOLING, AND VENTILATION NEEDS, AS PER THE PROJECT SPECIFICATIONS AND APPLICABLE CODES AND STANDARDS. 3. THE HVAC SYSTEM INSTALLATION SHALL COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL MECHANICAL CODE (IMC), INTERNATIONAL RESIDENTIAL CODE (IRC), AND ALL OTHER APPLICABLE LOCAL, STATE, AND NATIONAL CODES AND REGULATIONS. 4. THE EQUIPMENT SHOWN ON THIS DRAWING INCLUDES BUT IS NOT LIMITED TO AIR HANDLING UNITS (AHUS), CHILLERS, BOILERS, COOLING TOWERS, PUMPS, DUCTWORK, DIFFUSERS, GRILLES, AND CONTROL DEVICES. 5. ALL EQUIPMENT, DUCTWORK, AND PIPING SHALL BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS, LOCAL CODES, AND INDUSTRY BEST PRACTICES. 6. ALL DUCTWORK SHALL BE SIZED, FABRICATED, AND INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE ACCA MANUAL D AND THE SMACNA HVAC DUCT CONSTRUCTION STANDARDS. DUCTWORK SHALL BE INSTALLED IN A NEAT AND WORKMANLIKE MANNER, PROPERLY SUPPORTED AND BRACED TO PREVENT SAGGING, AIR LEAKAGE, OR VIBRATION. 7. CONDENSATE DRAINAGE PIPING SHALL BE PROPERLY PITCHED TO ENSURE POSITIVE DRAINAGE TO AN APPROVED DISPOSAL LOCATION, SUCH AS A FLOOR DRAIN, SUMP PUMP, OR EXTERIOR GRADE. CONDENSATE LINES SHALL BE INSULATED TO PREVENT SWEATING. 8. THE LOCATION OF CONTROL PANELS AND SENSORS INDICATED ON THIS DRAWING CAN BE MODIFIEDwith THE SPECIFIC LOCATIONS AND WIRING DETAILS WILL BE DETERMINED DURING THE CONTROL SYSTEM DESIGN AND INSTALLATION. 9. THE HVAC SYSTEM DESIGN CONSIDER ENERGY EFFICIENCY, INDOOR AIR QUALITY, OCCUPANT COMFORT, AND NOISE CONTROL, FOLLOWING APPLICABLE GUIDELINES AND REGULATIONS. 10. COORDINATION WITH OTHER TREADS HAS BEEN DONE ON A DESIGN LEVEL. THIS DRAWING SHALL BE READ TOGETHER WITH THE AR, EL AND SN DESIGN DRAWINGS TO ENSURE PROPER INSTALLATION AND INTEGRATION OF THE HVAC SYSTEMS. 11. THE HVAC CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS AND LICENSES, AND FOR SCHEDULING AND COORDINATING WITH THE LOCAL BUILDING DEPARTMENT AND UTILITY PROVIDERS TO ENSURE A TIMELY AND COMPLIANT INSTALLATION. 12. ALL DUCTWORK PENETRATIONS THROUGH WALLS, FLOORS, OR CEILINGS SHALL BE PROPERLY SEALED AND FIRE-STOPPED USING APPROVED METHODS AND MATERIALS TO MAINTAIN THE INTEGRITY OF THE BUILDING'S FIRE-RESISTANCE RATINGS. 13. HVAC EQUIPMENT SHALL BE INSTALLED LEVEL AND PLUMB, AND IN STRICT ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION INSTRUCTIONS AND RECOMMENDATIONS. PROVIDE ADEQUATE CLEARANCES AROUND EQUIPMENT FOR PROPER AIRFLOW, SERVICE ACCESS, AND CODE COMPLIANCE. 14. ALL HVAC EQUIPMENT AND COMPONENTS, INCLUDING THERMOSTATS, DAMPERS, AND ACCESS PANELS, SHALL BE LOCATED IN ACCESSIBLE AREAS FOR EASY SERVICING AND MAINTENANCE. PROVIDE ADEQUATE SPACE AROUND EQUIPMENT FOR PROPER AIRFLOW AND SERVICE ACCESS. 15. THE HVAC SYSTEM SHALL BE BALANCED AND ADJUSTED TO ENSURE PROPER AIRFLOW, TEMPERATURE DISTRIBUTION, AND SYSTEM PERFORMANCE THROUGHOUT THE RESIDENCE. PROVIDE A WRITTEN REPORT DOCUMENTING THE FINAL SYSTEM BALANCE. 16. ANY DEVIATIONS OR MODIFICATIONS TO THE HVAC SYSTEM DESIGN SHALL BE REVIEWED AND APPROVED BY THE RESPONSIBLE DESIGN PROFESSIONALS AND COMMUNICATED TO ALL RELEVANT PARTIES INVOLVED IN THE CONSTRUCTION PROCESS. 17. FOR ANY INQUIRIES OR CLARIFICATIONS REGARDING THE HVAC SYSTEM DESIGN, PLEASE CONSULT THE RESPONSIBLE DESIGN PROFESSIONALS OR THE PROJECT MANAGEMENT TEAM.

AA, Ethiopia Info@housedocs.store www.housedocs.store

KEY PLAN

∅ 3/4"

AIR HANDLING UNIT

AIR HANDLING UNIT

Hood-Wall

Condenser

NO.

DESCRIPTION

DATE

∅ 3/4"

EXHAUST FAN

∅ 3/4"

NOTE:

∅ 3/4"

AIR HANDLING UNIT

SYMBOLS

VAINED ELBOW; TYPICAL AT ALL SQUARE AND RECTANGULAR ELBOWS

SUPPLY DIFFUSER

LEGEND:

EXHAUST FAN

VAINED ELBOW; SHORT RADIUS

3/4"

∅ 3/4"

STANDARD RADIUS ELBOW

RETURN DIFFUSER

6' - 8"

3' - 2 1/2"

3' - 2 1/2"

Supply DUCT

AIR HANDLING UNIT

RETURN DUCT

EXHAUST DIFFUSER

PROJECT

IMMENSE-550

3/8" = 1'-0" 1 HVAC PLAN

Air handling unit

SIDEWALL SUPPLY DIFFUSER

FLEXIBLE CONNECTION

transition

MECHANICAL EQUIPMENT SCHEDULE

REFRIGERANT LINE SCHEDULE

FC

DRAWING NAME

ELEVATION INCLINE - RISE; IN DIRECTION OF FLOW ELEVATION INCLINE - DROP; IN DIRECTION OF FLOW

CATAGORY

DESCRIPTION

COUNT

CATAGORY

DESCRIPTION

DIAMETER

LENGTH

R

HVAC PLAN

Air condenser

AIR HANDLING UNIT AIR HANDLING UNIT: WALL MOUNTED

4 1 2 1

Pipe Types Pipe Types Pipe Types Pipe Types

Copper Copper Copper Copper

1/4" 3/8" 1/2" 3/4"

0.66

D

CONDENSER Exhaust Fan RANGE HOOD

Condenser: OUT DOOR EXHAUST FAN: 75 CFM

67.08

0.69

Hood-Wall: VENT

112.37

DUCT hanger

CONNECT NEW DUCT TO EXISTING DUCT

E

N

DUCT FITTING SCHEDULE

Owner 15_0001

DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:

REFRIGERANT LINE FITTING SCHEDULE

CATAGORY

DESCRIPTION

COUNT

CATAGORY

DESCRIPTION

Size

Count

Round Transition - Angle

45 Degree

5

8/5/2025 1:10:30 AM

Designer

Elbow - Generic

Elbow - Generic: Standard/HVAC Elbow - Generic: Standard/HVAC Elbow - Generic: Standard/HVAC Elbow - Generic: Standard/HVAC

1/2"ø-1/2"ø 1

FLEX DUCT SCHEDULE

housedocs.store

CHECKED BY: DRAWN BY:

Elbow - Generic

1/4"ø-1/4"ø 1

DESCRIPTION DESCRIPTION

LENGTH

DIAMETER COUNT

Checker

Elbow - Generic

3/4"ø-3/4"ø 29

Flex Duct Round FLEX-ROUND

15.062 15.062

4"

4

Elbow - Generic

3/8"ø-3/8"ø 21

Grand total: 4

Tee - Generic

Tee - Generic: Standard

3/4"ø-3/4"ø-3/ 4"ø 3/8"ø-3/8"ø-3/ 8"ø

3

M101

DUCT ACCESSORY SCHEDULE

Tee - Generic

Tee - Generic: Standard

3

CATAGORY

DESCRIPTION

COUNT

Transition - Generic Transition - Generic

Transition - Generic: Standard 3/4"ø-1/2"ø 9 Transition - Generic: Standard 3/8"ø-1/4"ø 1

ROOF VENT

3'' DIAMETER

4

SCALE:

As indicated