Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com
AA, Ethiopia Info@housedocs.store www.housedocs.store
NOTES: LIGHT
KEY PLAN
1. 2.
LIGHT FIXTURES AND LUMINARIES SHALL CONFORM TO THE NEC, THE IRC AND LOCAL SAFETY & BUILDING CODE. ALL LIGHTING FIXTURES SHOULD CONFORM TO THE DESIGN ELECTRICAL LOAD AND SHALL BE PROPERLY WIRED AND MOUNTED BY QUALIFIED ELECTRICIAN FOLLOWING MANUFACTURERS SPECIFICATIONS. CEILING FANS AND FANS WITH LIGHT WITH WEIGHT EXCEEDING 35 LBS SHOULD BE PROVIDED WITH STRUCTURAL BACKING FOR SUPPORT AND SHALL BE FIXED AS PER MANUFACTURERS SPECIFICATIONS. EXTERIOR LIGHTS SHALL CONFORM TO LOCAL BUILDING CODE AND GUIDELINES.
2' - 0 1/16" 2' - 7 15/32"
2' - 5 7/32" 2' - 0 9/32"
2' - 0 1/2"
4' - 0 1/16"
3' - 10 5/16"
2' - 0 1/4"
3.
4.
NOTES: SWITCH JUNCTION BOX
NO.
DESCRIPTION
DATE
3' - 9 3/8"
5' - 1"
2' - 1 11/16"
1. 2. 3. THE MINIMUM SIZE OF JUCTION BOX TO BE USED IS 2''X4''X(1.5'' OR 3.5'' DEEP) THIS ARE TO BE USED FOR SINGLE GANG SWITCH OR OUTLETS. FOR DOUBLE GANG (2 GANG) OUTLETS AND SWITCHS THE MINIMUM SIZE OF THE JUCTION BOX TO BE PROVIDED SHALL NOT BE LESS THAN 4''X4"X(1.5'' OR 3.5'' DEEP) FOR THREE GANG (3 GANG) OUTLETS AND SWITCHS THE MINIMUM SIZE OF THE JUCTION BOX SHALL NOT BE LESS THAN 6''X4"X(1.5'' OR 3.5'' DEEP).
1' - 3 13/32" 2' - 7"
2' - 7"
4' - 6 21/32"
2' - 11 3/4"
4' - 8 5/8"
4' - 8 5/8"
1' - 5 11/16"
NOTE:
Conduit Fitting Schedule(junction box) Family Count
Description
Conduit Junction Box - Cross - Aluminum 5 Conduit Junction Box - Tee - Aluminum 8 pullbox1 37
#1/4 pullbox
LEGEND:
Electrical Fixture Schedule (SWITCH BOX) Type Count
Double Gang Switch Box Single Gang Switch Box
8 5
Lighting Device
2' - 0 11/32"
5' - 1 11/16"
6' - 9 23/32"
2' - 0 5/16"
Type
Count
Dimmer
1 2 4 7 2 6
Fan switch
PROJECT
Fan switch with Dimmer
2' - 0 15/16"
4' - 7 13/16"
4' - 6 9/32"
2' - 0 7/32"
Single Pole Three Way
IMMENSE-550
1' - 9"
9' - 0"
24' - 5"
Three Way with Dimmer
Lighting Fixture
Lighting Fixture Type
Voltage
Electrical Load
Count
Ceiling Light - Flat Round 120 V/1-60 VA
<varies>
8 4
DRAWING NAME
Electrical_Lights_Fan-Li ght1 Lighting_Pendant_Tom-Di xon_Beat-Tall-Pendant2 SASSO 100 round wallwasher trim1 Wall Lamp - Bracket WATERPROOF RECESSED CEILING LIGHT
120 V/1-100 VA- 120 V/1-100 VA
200 A, 120 V/240 V, Single Phase, 3 Wires 200 A, 120 V/240 V, Single Phase, 3 Wires 200 A, 120 V/240 V, Single Phase, 3 Wires 200 A, 120 V/240 V, Single Phase, 3 Wires 200 A, 120 V/240 V, Single Phase, 3 Wires
DIMENSION PLAN FOR LIGHT FIXTURES
120 V/1-100 VA
3
3/8" = 1'-0" 1 DIMENSION FOR LIGHT FIXTURES
120 V/1-10 VA
16
120 V/1-100 VA
5
120 V/1-15 VA
2
Owner 0426_15
DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:
8/5/2025 11:29:20 AM
Designer
housedocs.store
CHECKED BY: DRAWN BY:
Checker
E104
SCALE:
3/8" = 1'-0"
© [2024] [FrameUpNow] . All rights reserved