LEGEND
Titan Bolt with RCA-C223 Connector For Load Bearing Wall Titan THD10x80 Shot Pins with Washer For Non-Load Bearing Wall
1/2" minimum diameter anchor at maximum of 48" OC. Bolts shall extrend a minimum of 4" into concrete. Anchor bolts shall be located not more than 12" from corners or the ternination of bottom tracks.
Single Strap Bracing Double Strap Bracing Racking Resistace Brace Material Type
SS
DS
SS1-2.0
DS
Bracing Types
DS1 SS1
Double 250-33-50 Strap 10g- Single 250-33-50 Strap 10g-
SD5/6 D1
SS
SS
SS
DS
SS
S
C000049986 EXP:06/30/2030 V
Scale- 1/4": 1'-0" Hold-down Plan
Immense 2730 E Turney Ave, Phoenix, AZ 85016
SCALE
DATE DRAWN 08-05-2025
DRAWN
JOB REFERENCE
REVISION
JOB DETAILS
S7
1/4" : 1'-0"
500
BA
ADDRESS
VIEW NAME
ON
DWG FILE Immense-550
9 of 16
36 x 24
COLD FORMED STEEL SKELETON ONLY