Immense eBook PDF

PIPE SCHEDULE

SHEET LIST

WASTE FIXTURE UNIT SCHEDULE

PIPe Color SCHEME

DOMESTIC COLD WATER DOMESTIC HOT WATER SANITARY VENT

Material

Diameter

Length

Sheet Number

Sheet Name

Family

QTY

DFU Values

TOTAL

Tuscon,AZ, USA 888-864-0184 inquire@frameupnow.com www.frameupnow.com

Acrylonitrile Butadiene Styrene (ABS) Acrylonitrile Butadiene Styrene (ABS) Acrylonitrile Butadiene Styrene (ABS) Cross-linked polyethylene (PEX) Cross-linked polyethylene (PEX)

1 1/2"

25 ft 75 ft 42 ft 67 ft

P101 P102

NOTE AND SCHEDULE

Bath Tub

2 1 1 8 1 1 2 1 2 1

0 0 0 0 0 0 0 0 0 0 0

SANITARY SEWER STORM DRAINAGE Gray Water GAS LINE

2" 3"

WATER SUPPLY AND SEWAGE SYSTEM

Dishwasher

Dryer

1/2" 3/4"

Hanging pipes clamp1

112 ft 34 ft

Hose Bib1

Polyvinyl Chloride - Rigid

2"

Shutoff Valve1 Sink Island Single

10

PLUMBING NOTES

AA, Ethiopia Info@housedocs.store www.housedocs.store

Vanity Sink

Washer

FITTING SCHEDULE

Water Closet Water Heater

1.

The plumbing system is designed to meet the building's domestic water supply, sanitary drainage, and storm drainage requirements, as per project specifications and applicable codes. The system installation shall comply with the latest International Plumbing Code (IPC), International Residential Code (IRC), and all other relevant local, state, and national regulations. ALL PLUMBING WORK SHALL COMPLY WITH THE LATEST EDITION OF THE INTERNATIONAL PLUMBING CODE (IPC) AND THE LOCAL PLUMBING CODE. PLUMBING SYSTEMS SHALL BE TESTED AND INSPECTED IN ACCORDANCE WITH THE LOCAL PLUMBING CODE REQUIREMENTS. PLUMBING FIXTURES SHALL BE INSTALLED WITH THE APPROPRIATE TRIM, FITTINGS, AND ACCESSORIES, AS RECOMMENDED BY THE MANUFACTURER. PIPING SHALL BE PROPERLY SUPPORTED AND SECURED TO PREVENT SAGGING, MOVEMENT, AND VIBRATION. SHUT-OFF VALVES SHALL BE PROVIDED AT ALL BRANCH CONNECTIONS AND AT THE INLET AND OUTLET OF EACH PIECE OF EQUIPMENT. BACKFLOW PREVENTION DEVICES SHALL BE INSTALLED AS REQUIRED BY THE LOCAL PLUMBING CODE TO PROTECT THE POTABLE WATER SYSTEM. PLUMBING FIXTURES AND EQUIPMENT SHALL BE ACCESSIBLE FOR MAINTENANCE AND SERVICING. EXPOSED PLUMBING PIPING AND FIXTURES SHALL BE INSULATED TO PREVENT CONDENSATION AND ENERGY LOSS. DEAD ENDS IN THE DRAINAGE SYSTEM MUST BE AVOIDED, EXCEPT WHERE NECESSARY TO INSTALL A CLEANOUT IN AN ACCESSIBLE LOCATION, AND MUST HAVE A VENTED CONNECTION TO THE OUTSIDE ATMOSPHERE. THE VERTICAL DEFLECTION OF PVC PIPE MUST NOT EXCEED 5%, AND NO DEFLECTION IS PERMITTED FOR IRON PIPE. WORK MUST BE PROPERLY COORDINATED WITH OTHER TRADES TO AVOID CONFLICTS, REFERRING TO THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR INFORMATION REGARDING CEILING ELEVATIONS, SPACE CLEARANCES, WALL AND PARTITION LOCATIONS, ETC. ALL FIXTURES SHALL HAVE ACCESSIBLE STOPS. DOMESTIC WATER PIPING SHALL BE PEX, AND PVC PIPING IS NOT ACCEPTABLE FOR INTERIOR USE. VENT TERMINATIONS SHALL BE LOCATED AT LEAST 10 FEET FROM OR 3 FEET ABOVE ANY OPERABLE WINDOW, DOOR OPENING, AIR INTAKE, OR VENT SHAFT, AND AT LEAST 3 FEET IN EVERY DIRECTION FROM ANY LOT LINE, ALLEY, OR STREET. PIPE AND FITTINGS UTILIZED IN THE WATER SUPPLY SYSTEM SHALL HAVE A MAXIMUM OF 8 PERCENT LEAD. ACRYLONITRILE BUTADIENE STYRENE (ABS) SHALL BE USED FOR THE SEWERAGE AND VENTILATION SYSTEM. CROSS-LINKED POLYETHYLENE (PEX) SHALL BE USED FOR THE WATER SUPPLY SYSTEM. POLYVINYL CHLORIDE (PVC) SHALL BE USED FOR THE RAIN WATER SYSTEM. THE MIMIMUM WATER SUPPLY DEPTH UNDER FLOOR FINISH SHOUD BE 1/2". ANY PIPE INSTALLED UNDERGROUND MUST HAVE AT LEAST 12 INCHES OF CLEARANCE BETWEEN THE OUTSIDE OF THE PIPE AND ANY OTHER UNDERGROUND STRUCTURE. THE MINIMUM CLEARANCE BETWEEN COLD AND HOT WATER LINES IN RESIDENTIAL HOMES MAINTAIN A MINIMUM DISTANCE OF 6 INCHES. HORIZONTAL SEPARATION BETWEEN WATER AND SEWER LINES : A MINIMUM OF 12 INCHES BETWEEN POTABLE WATER SUPPLY LINES (COLD AND HOT WATER) AND SANITARY SEWER LINES.

FITTING

Size

QTY

KEY PLAN

2.

PEX 90 Degree Elbow PEX 90 Degree Elbow

1/2"ø-1/2"ø 3/4"ø-3/4"ø

14

PLUMBING SCHEDULE

4 1 9 8 5 5 6 1 3 2 1 5 2 2 2 1 2 1 1 3 1 1 1 2 2 2 2

PEX Tee Elbow PEX Tee Elbow

1/2"ø-1/2"ø-1/2"ø 3/4"ø-3/4"ø-3/4"ø

FIXTURE

Trap Waste

Vent

C.W

H.W

3. 4. 5. 6. 7. 8. 9.

PEX Transition Elbow PEX 90 Degree Elbow PEX 90 Degree Elbow

3/4"ø-1/2"ø 1/2"ø-1/2"ø 3/4"ø-3/4"ø

Bath Tub

1-1/2" 1-1/2" 1-1/2" 1-1/2" N/A

2" 2" 2" 2" 2" 3"

1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" N/A

1/2" 1/2" N/A 1/2" 1/2" 1/2" 1/2"

1/2" 1/2" N/A 1/2" 1/2" 1/2" 1/2"

13

Dishwasher

Dryer

N/A

PEX Tee Elbow

3/4"ø-3/4"ø-3/4"ø

Sink Island Single

PEX Transition Elbow

3/4"ø-1/2"ø

Vanity Sink

PVC 90 Degree Bend Elbow ABS 90 Degree Bend Elbow ABS 90 Degree Bend Elbow ABS 90 Degree Bend Elbow ABS Bend Long Sweep Elbow

2"ø-2"ø

12

Washer

2" 3"

1 1/2"ø-1 1/2"ø

Water Closet Water Heater

2"

2"ø-2"ø 3"ø-3"ø 2"ø-2"ø

NO.

DESCRIPTION

DATE

ABS P-Trap ABS P-Trap

1 1/2"ø-1 1/2"ø

2"ø-2"ø

ABS Reducer Elbow

2"ø-1 1/2"ø

10. 11.

WATER FIXTURE UNIT SCHEDULE

ABS TEE Elbow ABS TEE Elbow ABS TEE Elbow

1 1/2"ø-1 1/2"ø-1 1/2"ø

Family

QTY

UNIT VALUE

TOTAL

2"ø-2"ø-2"ø 3"ø-3"ø-3"ø 2"ø-2"ø-2"ø 3"ø-2"ø-3"ø 3"ø-3"ø-2"ø 3"ø-3"ø-3"ø 3"ø-3"ø-1 1/2"ø 2"ø-2"ø-2"ø-2"ø 1 1/2"ø-1 1/2"ø 3"ø-3"ø-1 1/2"ø

ABS Tee Reducer Elbow ABS Tee Reducer Elbow ABS Tee Reducer Elbow ABS Tee Reducer Elbow ABS Tee Reducer Elbow

Bath Tub

2 1 1 8 1 1 2 1 2 1

0 0 0 0 0 0 0 0 0 0 0

12. 13.

Dishwasher

Dryer

Hanging pipes clamp1

Hose Bib1

ABS Wye Combination with 8th Bend Double Elbow

Shutoff Valve1 Sink Island Single

10

NOTE:

14. 15. 16. 17. 18. 19. 20. 21. 22. 23. 24.

ABS 90 Degree Bend Elbow ABS Tee Reducer Elbow

Vanity Sink

Washer

ABS Vent Cap Elbow ABS Vent Cap Elbow

2"ø 3"ø

Water Closet Water Heater

LEGEND:

FIXTURE CONNECTION SCHEDULE W V Trap CW HW QTY DFU TOT. WFU TOT.

Family

NOTES

Bath Tub

2" 1-1/2" 1-1/2" 1/2" 1/2" 2 2" 1-1/2" 1-1/2" 1/2" 1/2" 1 N/A N/A N/A N/A N/A 1

0 0 0 0 0 0 0 0 0 0 0

Drain to sewer see plans

Dishwasher

Dryer

Hanging pipes clamp1

8 1

Hose Bib1

Shutoff Valve1

10

Sink Island Single 2" 1-1/2" 1-1/2" 1/2" 1/2" 1

ABBREVIATIONS

PLUMBING LEGEND

Vanity Sink

2" 1-1/2" 1-1/2" 1/2" 1/2" 2

DRAINS TO GRAY WATER OR SEWER SEE PLANS

Washer

2" 1-1/2"

2" 3"

1/2" 1/2" 1 1/2" 1/2" 2

Ø ABS ABV AD AFF ALT BFF BLW CO CW D DFU DIA DN FCO FD FL FS FT HB HW IN MIN NO NTS PEX PLBG RM RW SF V VTR W WCO WSFU PVC QTY RD RED

Diameter ACRYLONITRILE BUTADIENE STYRENE ABOVE AREA DRAIN ABOVE FINISHED FLOOR ALTERNATE BELOW FINISHED FLOOR BELOW CLEAN OUT COLD WATER DEGREE Dranage FIXTURE UNIT DIAMETER DOWN FLOOR CLEAN OUT FLOOR DRAIN FLOOR

Cap

Water Closet Water Heater

3"

2"

1

Bend 45 Deg

PROJECT

Bend 90 Deg

IMMENSE-550

FIXTURE SCHEDULE

Tee Reducing

fixture

QTY

Description

Tee

Bath Tub

2 1 1 8 1 1 2 1 2 1

Clean Two-Way

Dishwasher

Drain to sewer see plans

Dryer

DRAWING NAME

Hanging pipes clamp1

Wye 45 Deg

NOTE AND SCHEDULE

Hose Bib1

Shutoff Valve1 Sink Island Single

10

Wye 45 Deg Double

FLOOR SINK FOOT/FEET HOSE BIB HOT WATER INCH

Vanity Sink

Washer

DRAINS TO GRAY WATER OR SEWER SEE PLANS

Wye Combination

Water Closet Water Heater

MINIMUM NUMBER NOT TO SCALE CROSS-LINKED POLYETHYLENE PLUMBING POLYVINYL CHLORIDE Quantity ROOF DRAIN REDUCER ROOM RAIN WATER SQUARE FOOT VENT VENT THROUGH ROOF WASTE WALL CLEAN OUT WATER SUPPLY FIXTURE UNIT

DATE: PROJECT NUMBER: DESIGNED BY: CLIENT NAME:

P-Trap

0426

8/5/2025 11:12:22 AM

ACCESSORIES & FITTINGS SCHEDULE

Designer

fixture

QTY

Descriptions

housedocs.store

CHECKED BY: DRAWN BY:

Checker

DISHWASHER CONNECTOR LAUNDRY SWEAT CONNECTOR

1 1

P101

SCALE:

1/2" = 1'-0"

© [2024] [FrameUpNow] . All rights reserved