Lips of header plate notched out to receive stud

Lips of nog notched out to receive stud

Web of head notched out to receive stud

Stud section swaged to allow neat fit inside plate

Web of nog notched to allow stud to pass

Web of header plate notched to allow stud to pass

Nog section swaged to allow neat fit inside stud

Stud section swaged to allow neat fit inside plate

Lips of head notched out to receive stud

Stud swaged to fit inside header plate

Plate to Jamb Stud Connection

Lips of plate notched out to recieve stud

Header Plate to Jamb Stud Connection

Web of sill notched to allow stud to pass

Header Plate to Jamb Stud Connection

Plate to Jamb Stud Connection

Stud section swaged to allow neat fit inside plate

End of brace swaged to allow neat fit inside plate

Lips of sill notched out to receive stud

Sill Plate to Jamb Stud Connection

Lips of plate notched out to receive stud and brace

Web of nog notched to allow stud to pass

Base of stud swaged to allow neat fit inside plate

Base of stud swaged to allow neat fit inside plate

Studs screwed together at max 6", alternating side of web

Stud section swaged to allow neat fit inside plate

Lips of plate notched out to recieve stud

End of stud swaged to allow neat fit inside plate

Lips of nog notched out to receive stud

Lips of plate notched out to recieve stud

K Brace to Bottom Plate Connection

out to recieve stud

Stud to Bottom Plate Connection

End Stud to Bottom Plate Connection

NOTE: Unless noted otherwise, use 1x10g screws for all connections

Back to Back Stud Connection

01

02

LOAD BEARING WALL PANEL ASSEMBLY

NON-LOAD BEARING WALL PANEL ASSEMBLY

S/LS CONNECTOR WITH #10 SCREWS

S/LS50 CONNECTOR

Strap Brace

Studs as per engineering

Top Plate

2 x 10g screws

2 x 10g screws

2 x 10g screws

Strap Tensioner

Hold-down RCA-C223 CONNECTOR WITH STRONG BOLT

Concrete Foundation

Standard Site Connections "T" Junction

Standard Site Connections "L" Corner

Standard Site Connections "INLINE"

Standard Site Connections "Angled" Connection

#10 SELF-DRILLING SCREW

Nog/Blocking

Connect to foundation with Screw Anchor or Wedge Anchor, according to manufctur'sspecifications.

studs located for internal lining fixing

studs located for internal lining fixing

1/2" Ø ANCHOR

250 S 33mil 50ksi Strap

Attach each end of strap to studs with 10g Flat Head screws as per Engineering. After ends are connected each strap must be tensioned with one strap tensioner. Post tension, strap must be screwed to each stud it crosses using 10g Flat Head screws.

2 x 10g screws

2 x 10g screws

2 x 10g screws

S/LS CONNECTOR WITH #10 SCREWS

Note: for connections between braced walls use connections specified by the Engineer

03

04

GENERAL WALL TO WALL CONNECTION

STRAP BRACE TO WALL CONNECTION

350S 33mil 50ksi

PRE-MANUFACTURED TRUSSES

PRE-MANUFACTURED TRUSSES

Back to back studs

8'-0"

7'-0"

6" OPEN CELLR-38 INS. IN CEILING

2'-0"

2'-0"

2'-0"

2'-0"

10g or 12 g screws, as per Engineering

5'-0"

Electrical Distribution Panel Board

VENTED 2X4 BLK

(RECOM) RCA 225 RIGID CONNECTOR (OPTIONAL) S/H2.5 CONNECTOR WITH #10 SCREWS

Nogs For Electrical Panel Backing

1 3 8 "

1 3 8 "

4'-6"

4'-0"

Hold-down RCA-C223 CONNECTOR WITH STRONG BOLT

(RECOM) RCA 223 RIGID CONNECTOR (OPTIONAL) S/H2.5 CONNECTOR WITH #10 SCREWS

6'-0" 2'-0"

4'-0"

Extra 10g screw to each stud

2'-0"

2'-0"

2'-0"

2X6 FASCIA

#10 SELF-DRILLING SCREW

1 3 8 "

1 3 8 "

1'-0"

2X6 FASCIA

Wall face Recessed Electrical Panel

3'-0"

VENTED 2X4 BLK

1/2" DRYWALL

1/2" Ø ANCHOR

3'-0"

Studs as per engineering

Hold-down RCA-C223 CONNECTOR

BEAM ASSEMBLY 350 S 43mil 50ksi

4" OPEN CELL R-19 INS. IN WALLS

Strap Brace

TIE PLATE CONNECTOR WITH #10 SCREWS

ONE COAT STUCCOSYSTEM

1 3 8 "

1 3 8 "

Electrical Distribution Panel Board

Hold-down RCA-C223 CONNECTOR WITH STRONG BOLT

Hold-down RCA-C223 CONNECTOR WITH STRONG BOLT OR TITAN HD SCREW ANCHOR

Nogs For Electrical Panel Backing

550S 162 33mil 50ksi @ 24" O.C.

SHEAR PANEL

(RECOM) RCA 223 RIGID CONNECTOR (OPTIONAL) S/H2.5 CONNECTOR WITH #10 SCREWS

33 MIL TRACK TYP.

S

4X6 POST

RCA 223

TRACK

TIE PLATE

Connect to foundation with Screw Anchor or Wedge Anchor, according to manufctur'sspecifications.

1-3/8" PANELS EDGE A 1-3/8"

1-3/8" B

1-3/8"

C000049986 EXP:06/30/2030 V

Recessed Electrical Panel

Concrete Foundation

INLINE PANELS

05

06

07

08

09

ELECTRICAL PANEL BACKING HEIGHT

LOAD BEARING WALLS

POST / BEAM CONN.

WALL / TRUSS CONN.

TYPICAL ANCHOR BOLT & BOLT HOLE LOCATION

Immense 2730 E Turney Ave, Phoenix, AZ 85016

SCALE

DATE DRAWN 08-05-2025

DRAWN

JOB REFERENCE

REVISION

JOB DETAILS

D1

1/4" : 1'-0"

500

BA

ADDRESS

VIEW NAME 10 of 16

ON

DWG FILE Immense-550

36 x 24

COLD FORMED STEEL SKELETON ONLY

Made with FlippingBook Online newsletter maker