Regulations

All installations must comply with guidelines which are based on a zonal concept. The diagram illustrates this concept and must be followed to ensure the safe installation of electrical appliances in the bathroom. These regulations apply to domestic installations only in accordance with BS 7671 bathroom requirements. Installations must be made in accordance with the current IEE wiring regulations and relevant building regulations. hib recommends that all electrical bathroom products should only be fitted by a suitably qualified, Part P registered electrician.

Zone 1 refers to the area above the bath/shower up to a height of 2.25 metres and requires a minimum rating of IPX4 or higher. IP65 is commonly fitted for downlights. All bathroom circuits must use a 30mA RCD to protect the circuit.

Zone 2 covers an area 0.6 metres wide

Outside Zone has no special requirements, unless water jets are likely to be used for cleaning purposes. Standard fittings may be used if suitable for the environment.

immediately next to, and all round zone 1. Wash basins should also be treated as zone 2. The minimum rating here is IPX4. IP44 or IP65 mirror lighting are common compliant choices.

First Numeral Protection against ingress of foreign bodies, e.g. tools, dust, fingers, etc. 1. Protected against solid objects with a diameter of 50mm and over (e.g. Accidental insertion of hands). 2. Protected against solid objects over 12mm (e.g. jointed fingers). 3. Protected against solid objects over 2.5mm (tools). 4. Protected against solid objects over 1mm (small wires). 5. Protected against dust - limited ingress permitted (no harmful deposit). 6. Totally protected against dust.

Second Numeral Protection against ingress of liquids. 1. Protected against drops of condensed water. Drops of condensed water falling on the enclosure shall have no harmful effect. 2. Protection against drops of liquid. Drops of falling liquid shall have no harmful effect when the enclosure is tilted at an angle up to 15 degrees from the vertical. 3. Protection against rain. Water falling in rain at an angle equal or smaller than 60 degrees with respect to the vertical shall have no harmful effect. 4. Protection against splashing. Liquid splashed from any direction shall have no harmful effect. 5. Protection against water jets. Water projected by a nozzle from any direction under stated conditions shall have no harmful effect. 6. Protection against conditions on ship decks (deck equipment). Water from heavy seas shall not enter the enclosures under prescribed conditions. 7. Protection against immersion in water. It shall not be possible for water to enter the enclosure under stated conditions of pressure and time. 8. Protection against indefinite immersion in water under specified pressure. It shall not be possible for water to enter the enclosure.

Please read for critical building compliance regulations for all electrical products.

The IP (Ingress Protection) Standard describes a uniform system for classifying the degrees of protection provided by the enclosures of electrical equipment. For example, if a bathroom’s light is rated IP65, then the 6 means it’s ‘Protected against Dust’ and the 5 means it’s ‘Protected against Water Jets’ from a shower, tap or cleaning processes from any direction.

Unless otherwise identified, our mirrors are not suitable for installation within a critical impact zone i.e. below 800mm (80cm) above finished floor level. The installer is responsible for ensuring compliance with all relevant building regulations and site-specific requirements. If in any doubt, contact hib product support for advice.

Need further information or advice? Please contact our customer service on +44 (0)20 8441 0352