Huber Brand Product Guide by Boise Cascade

ZIP SYSTEM ® WALL SHEATHING

22

HUBER HOUSE OF BRANDS

23

ZIP SYSTEM ® LONG LENGTH SHEATHING: TALLER, TOUGHER AND FEWER SEAMS Get all the benefits of engineered wood long length wall sheathing, with the built-in moisture and air leakage protection of ZIP System ® sheathing and tape technology. ZIP System long length sheathing and wind zone panels provide the flexibility of a longer panel with the ability to eliminate housewrap when used with ZIP System tape.

ZIP System ® sheathing and tape provides an excellent substrate for wall claddings including brick, siding, stucco or cedar shingles. The panels install flat and stay flat, ensuring a finished wall that looks as good as it performs. ZIP IT TIGHT ™ With a Variety of Cladding Materials

BIM collateral available at HuberWood.com.

SIDING

CEDAR SHAKES

BRICK CLADDING

ZIP System ® Long Length Panels

ZIP System ® Wind Zone Panels

Other Long Length Panels

Compare For Yourself

Protect Your Build From the Elements

X X X X X

X X X X X X X X

X X X X X X X X

More efficient panel installation

1

Helps eliminate blocking at horizontal panel seams 1

Fewer horizontal seams

Less panel cutting and waste

Integrated water-resistive barrier Self-spacing edge profile Continuous rigid air barrier Eliminates the need for housewrap

1

Can be designed to resist combined uplift and shear 1

2

Can eliminate the need for housewrap with built-in, vapor-permeable, water-resistive barrier

Continuous rigid air barrier decreases unwanted air leakage for greater energy efficiency

3

3

Backed by a 30-year Limited Warranty 2

4

Long length panel, water-resistive barrier, air barrier and seam sealer are an engineered system from the same manufacturer

X

X

X

X

Structural 1 rating for 7/16", 1/2" and 5/8" sizes 3

4

2

ZIP System ® Long Length Sheathing and Wind Zone Panels

Performance Category

Panel Size

Panel Count

PS-2 Span Rating 24/16 Structural 1 32/16 Structural 1 40/20 Structural 1

Code Evaluation Report

Air Barrier Assembly

Vapor Transmission of WRB Layer

Product

7/16

80

Sheathing

4' x 8'

ESR 1474

1/2

70

ASTM E 2357 0.008 cfm/ft ² [0.039 L/(s*m ² )] infiltration @ 75Pa ASTM E 2357 0.005 cfm/ft ² [0.023 L/(s*m ² )] exfiltration @ 75 Pa

ESR-1473 ESR-1474 ESR-2227

5/8

55

12-16 perms ASTM E 96 Procedure B

4' x 9' 4' x 10' 4' x 12'* 4' x 9' 4' x 10'

70 60 52 62 56 80 70 60 52

24/16 Structural 1

7/16

Long Length

32/16 Structural 1

ESR 1473 ESR 1474

1/2

ER-424 ER-544 Code documents available at HuberWood.com

4' x 8' 1-1/8"* 4' x 9' 1-1/8" 4' x 10' 1-1/8" 4' x 12' 1-1/8"*

24/16 Structural 1

Wind Zone

7/16

7/16" PANEL

1/2" PANEL

5/8" PANEL

1. See the American Wood Council, Special Design Provisions for Wind and Seismic, AWC SDPWS-2021. 2. Long length panels are permitted for wall applications only. Limitations and restrictions apply. View the ZIP System ® Wall Residential Warranty and/or Commercial Warranty at huberwood.com formore details.

3. 5/8" 9' and 10' panels available by special order.

*Available with minimum order quantity. Contact your Huber representative for more details.

Although all projects are unique, experience has shown that 1 roll of 3-3/4" ZIP System ™ flashing tape is needed for approximately 5-7 sheets of 4' x 8' ZIP System ® sheathing. This should only be considered a general “rule of thumb” when ordering materials with the understanding that some jobs may require more or less depending on the specific project.

Made with FlippingBook Digital Proposal Creator