ZIP SYSTEM ® R-SHEATHING
24
HUBER HOUSE OF BRANDS
25
1", 1-1/2", 2", 2-1/2" ZIP System ® R-sheathing
Nominal Total Thickness
Code Evaluation Report
Air Barrier Assembly
Panel Type
Panel Size Panel Count
R-value
ASTM E 2357 0.0072 cfm/ft ² [0.037 L/ (s*m ² )] exfiltration @ 75Pa ASTM E 2357 0.0023 cfm/ft ² [0.012 L/ (s*m ² )] exfiltration @ 75 Pa
R-3
1"
32
3.6
R-6
1-1/2"
31
6.6
4' x 8' 4' x 9' 4' x 10'
ESR 3373 ER 482
R-9
2"
23
9.6
R-12
2-1/2"
18
12.6
Foam Performance
ZIP System ® Performance
Property
TEST Method
Typical Results
Property
Test Method
Typical Results
Dimensional Stability
ASTM D 2126 < 2%
ASTM D 2247 (for 14 days)
Water Resistance of Coatings
Passed
Compressive Strength
ASTM D 1621 20 psi
Drainage Efficiency
ASTM E 2273
> 90%
ASTM C 209 ASTM D 2842
< 1% < 3.5%
Water Absorption
Water Vapor Transmission ASTM E 96B
12-16 perms (overlay)
Water Penetration
ASTM E 331
Passed
0.56 perm (Method A) 1.29 perm (Method B)
Water Vapor Transmission ASTM E 96
0.008 cfm/ft² (0.039 L/s*m²) infiltration 0.005 cfm/ft² (0.023 L/s*m²) exfiltration
ASTM E 2357 at 75 Pa
Density
ASTM D 1622 Nominal 2.0 pcf
Air Barrier Assembly
Flame Spread
ASTM E 84
40-60
Smoke Developed
ASTM E 84
50-170
Wind-Driven Rain
TAS-100
Passed 110mph
Tensile Strength
ASTM D 1623 > 730 psf
Accelerated Weathering
ASTM G154 (Cycle 1) Passed
Service Temperature
-40°F – 200°F
Long term thermal resistance values of the foam were determined in accordance with ASTM C 1289- 02. The R-Value of 0.55 for 7/16" OSB was obtained from ASHRAE Handbook, Fundamentals.
Fastening Requirements for Prescriptive Bracing 1,2 and Engineered Shear Wall Design 3
ZIP SYSTEM ® R-SHEATHING: INSULATES AND PROTECTS ZIP System R-sheathing is the simple all-in-one structural panel with built-in exterior polyisocyanurate insulation. Featuring integrated moisture, air and thermal protection, ZIP System R-sheathing completely reimagines traditional wall assemblies by streamlining exterior water, air and thermal management.
ER-482
Framing
Fasteners
Shear Values 5
ZIP System ® R-sheathing Type
Nominal Stud Spacing (min.)
Maximum Stud Spacing (in.)
Edge/Field Spacing (in.)
Minimum Penetration into Framing (in.)
Allowable Seismic Controlled Shear Values 5, 6 (plf)
Allowable Wind Controlled Shear Values 5 (plf)
Fastener Specifications 4
Available in R-3, R-6, R-9 and R-12 values and three lengths – 8ft, 9ft and 10ft – to suit all climate zones.
R-3
2-by-4
24
0.131" shank nails
4/12
1.5
245
343
R-3
2-by-4
24
0.131" shank nails
3/12
1.5
280
393
16ga staples, 7/16" crown, 2" length
R-3
2-by-4
16
3/6
1.0
210
294
R-6
2-by-4
24
0.131" shank nails
4/12
1.5
230
322
15ga staples, 7/16" crown, 2.5" length
R-6
2-by-4
24
3/6
1.0
NA 7
NA
R-6
2-by-4
24
0.131" shank nails
3/12
1.5
255
357
R-3
R-6
R-9
R-12
R-9
2-by-4
24
0.131" shank nails
3/12
1.5
240
336
R-12
2-by-4
24
0.131" shank nails
3/12
1.5
215
301
5. The shear walls must have a maximum height-to-width aspect ratio of 2:1. 6. ZIP System R-sheathing used as the lateral resistance system in seismic zones D 0 , D 1 , D 2 and E should be designed in accordance to ER-482. 7. This panel and fastening configuration is applicable to the prescriptive bracing requirements under the 2021 IRC.
For SI: Inch = 25.4mm; 1 pound per foot (ppf) = 14.59 N/m. * Structural design values can be found in ESR-3373. 1. Prescriptive bracing requirements under the 2021 IRC. 2. Not approved for use as prescriptive wall bracing where wind design is required by R301.2.1.1. 3. Engineered shear wall requirements with Douglas Fir-Larch Framing under the 2021 IBC. 4. Fasteners must be common nails or equivalent, or staples, of a type generally used to attach wood sheathing.