ZIP SYSTEM ® R-SHEATHING

24

HUBER HOUSE OF BRANDS

25

1", 1-1/2", 2", 2-1/2" ZIP System ® R-sheathing

Nominal Total Thickness

Code Evaluation Report

Air Barrier Assembly

Panel Type

Panel Size Panel Count

R-value

ASTM E 2357 0.0072 cfm/ft ² [0.037 L/ (s*m ² )] exfiltration @ 75Pa ASTM E 2357 0.0023 cfm/ft ² [0.012 L/ (s*m ² )] exfiltration @ 75 Pa

R-3

1"

32

3.6

R-6

1-1/2"

31

6.6

4' x 8' 4' x 9' 4' x 10'

ESR 3373 ER 482

R-9

2"

23

9.6

R-12

2-1/2"

18

12.6

Foam Performance

ZIP System ® Performance

Property

TEST Method

Typical Results

Property

Test Method

Typical Results

Dimensional Stability

ASTM D 2126 < 2%

ASTM D 2247 (for 14 days)

Water Resistance of Coatings

Passed

Compressive Strength

ASTM D 1621 20 psi

Drainage Efficiency

ASTM E 2273

> 90%

ASTM C 209 ASTM D 2842

< 1% < 3.5%

Water Absorption

Water Vapor Transmission ASTM E 96B

12-16 perms (overlay)

Water Penetration

ASTM E 331

Passed

0.56 perm (Method A) 1.29 perm (Method B)

Water Vapor Transmission ASTM E 96

0.008 cfm/ft² (0.039 L/s*m²) infiltration 0.005 cfm/ft² (0.023 L/s*m²) exfiltration

ASTM E 2357 at 75 Pa

Density

ASTM D 1622 Nominal 2.0 pcf

Air Barrier Assembly

Flame Spread

ASTM E 84

40-60

Smoke Developed

ASTM E 84

50-170

Wind-Driven Rain

TAS-100

Passed 110mph

Tensile Strength

ASTM D 1623 > 730 psf

Accelerated Weathering

ASTM G154 (Cycle 1) Passed

Service Temperature

-40°F – 200°F

Long term thermal resistance values of the foam were determined in accordance with ASTM C 1289- 02. The R-Value of 0.55 for 7/16" OSB was obtained from ASHRAE Handbook, Fundamentals.

Fastening Requirements for Prescriptive Bracing 1,2 and Engineered Shear Wall Design 3

ZIP SYSTEM ® R-SHEATHING: INSULATES AND PROTECTS ZIP System R-sheathing is the simple all-in-one structural panel with built-in exterior polyisocyanurate insulation. Featuring integrated moisture, air and thermal protection, ZIP System R-sheathing completely reimagines traditional wall assemblies by streamlining exterior water, air and thermal management.

ER-482

Framing

Fasteners

Shear Values 5

ZIP System ® R-sheathing Type

Nominal Stud Spacing (min.)

Maximum Stud Spacing (in.)

Edge/Field Spacing (in.)

Minimum Penetration into Framing (in.)

Allowable Seismic Controlled Shear Values 5, 6 (plf)

Allowable Wind Controlled Shear Values 5 (plf)

Fastener Specifications 4

Available in R-3, R-6, R-9 and R-12 values and three lengths – 8ft, 9ft and 10ft – to suit all climate zones.

R-3

2-by-4

24

0.131" shank nails

4/12

1.5

245

343

R-3

2-by-4

24

0.131" shank nails

3/12

1.5

280

393

16ga staples, 7/16" crown, 2" length

R-3

2-by-4

16

3/6

1.0

210

294

R-6

2-by-4

24

0.131" shank nails

4/12

1.5

230

322

15ga staples, 7/16" crown, 2.5" length

R-6

2-by-4

24

3/6

1.0

NA 7

NA

R-6

2-by-4

24

0.131" shank nails

3/12

1.5

255

357

R-3

R-6

R-9

R-12

R-9

2-by-4

24

0.131" shank nails

3/12

1.5

240

336

R-12

2-by-4

24

0.131" shank nails

3/12

1.5

215

301

5. The shear walls must have a maximum height-to-width aspect ratio of 2:1. 6. ZIP System R-sheathing used as the lateral resistance system in seismic zones D 0 , D 1 , D 2 and E should be designed in accordance to ER-482. 7. This panel and fastening configuration is applicable to the prescriptive bracing requirements under the 2021 IRC.

For SI: Inch = 25.4mm; 1 pound per foot (ppf) = 14.59 N/m. * Structural design values can be found in ESR-3373. 1. Prescriptive bracing requirements under the 2021 IRC. 2. Not approved for use as prescriptive wall bracing where wind design is required by R301.2.1.1. 3. Engineered shear wall requirements with Douglas Fir-Larch Framing under the 2021 IBC. 4. Fasteners must be common nails or equivalent, or staples, of a type generally used to attach wood sheathing.