EXACOR™ MgO Panels EXACOR ® WALL SHEATHING
40
HUBER HOUSE OF BRANDS
41
EXACOR ® PANELS STREAMLINE SCHEDULES
Gypsum Underlayment Process
The gypsum underlayment trade is typically scheduled 6-16 weeks in advance with a firm date that doesn’t allow for construction delays.
FINAL DRYWALL
GYPSUM PREP, POUR, CURE & SEAL
GYPSUM PRIMER
FRAMING DRY-IN DRYWALL
PAINT CABINETS
FLOORING
EXACOR ® Panel Process
FIRE-RATED SOLUTIONS FOR EXTERIOR WALL ASSEMBLIES
FINAL DRYWALL
EXA PREP & PRIMER
EXA UL
FRAMING
DRY-IN DRYWALL
PAINT CABINETS
FLOORING
POTENTIAL TIME SAVINGS
Continuous EXACOR ® layer under wall plates gives consistent IIC sound attenuation
Set tubs/shower pans directly on EXACOR ® to speed up plumbing inspections
Eliminate shoe molding when baseboards are installed at second trim (after finish floor)
EDUCATION
EXACOR ® Panels: On Time. On Budget.
CONTRACTOR FLOOR ASSEMBLY COST STRUCTURE*
Gypsum concrete Subfloor Assembly
EXACOR ® wall sheathing is rigorously tested to ensure fire-resistant performance in multifamily builds. In ASTM E84 and ASTM E119/UL 263 fire testing, our high-quality MgO panels were shown to resist the spread of flames and help delay fire from burning through to other materials, helping to protect building structural integrity during a fire event.¹ Unlike coated or treated sheathing, EXACOR panels are fire-resistant throughout, offering protection in harsh conditions. EXACOR wall sheathing can help optimize material and labor costs, and are easily installed by existing construction crews familiar with installing OSB or plywood sheathing. The panels provide durability and protection in 1 and 2-hour fire-rated wall assemblies.²
$3.0
LABOR
SOUNDMAT
EXACOR ®
GYPSUM UNDERLAYMENT
$2.0
$1.0
OSB SUBFLOOR
OSB SUBFLOOR
OSB LABOR
OSB LABOR
UL263 L5281 1-Hour Fire Rated Floor / Ceiling Assembly
$0.0
1/2" EXACOR ® Underlayment Assembly
Gypsum Underlayment Assembly
1. EXACOR panels may be used in specific published fire-resistant rated assemblies as tested in accordance with ASTM E119/ANSI UL 263. Follow published fire-resistance rated assembly requirements and consult local building codes and designer of record for fire-resistant design requirements. 2. See ESL-1290 for full assembly details and requirements.
The construction processes shown are examples only and may not be suitable for all scenarios. Processes will vary on a case by case basis.
*This cost estimation is an example only, and pricing for labor and materials varies widely by region. Seek pricing for your market from local partners. All prices subject to market vari- ability and availability.