Phase Electrical General Catalogue

ENERGY CONTROL Sangamo RPTS

S250 Standard

Round Pattern Time Switch Sangamo have manufactured the renowned RPTS from their Port Glasgow factory since 1951, having sold over 11 million switches and counting. These 20A switches are famous for their high capacity, quality and reliability and are backed by a five-year guarantee.

• 20A rated 24 hour SPST time switch. • Fixed time switching with 2 or 3 on/off periods per day. • Day omit dial. • Temporary Override (manual button).

• 20A rated 24 hour SPST time switch. • 100 hour battery reserve. • Fixed time switching with 2 or 3 on/off periods per day. • Day omit dial. • Temporary Override (manual button). Q550 Standard

Part No.

Description

S254.2 S254.3 S255.2 S255.3

3-pin with 2 on/off operations, Day Omit skips ON operation 3-pin with 3 on/off operations, Day Omit skips ON operation 4-pin with 2 on/off operations, Day Omit skips ON operation 4-pin with 3 on/off operations, Day Omit skips ON operation

Part No. Q554.2 Q554.3 Q555.2 Q555.3 Q557.2 Q557.3 Q559.2 Q563.2 Q563.3 Q586.2

Description

E850 Digital

3-pin with 2 on/off operations, Day Omit skips ON operation 3-pin with 3 on/off operations, Day Omit skips ON operation 4-pin with 2 on/off operations, Day Omit skips ON operation 4-pin with 3 on/off operations, Day Omit skips ON operation

• 20A rated 7 day SPST time switch. • The same RPTS quality in a digital unit, allowing for more complex switching patterns. • Clear and easy to program LCD display. • Temporary Override (manual button).

Variants

As Q555.2 but Day Omit skips OFF operation As Q555.3 but Day Omit skips OFF operation As Q555.2 with Early OFF on a select day As Q555.2 but 10/20A SPDT Changeover As Q555.3 but 10/20A SPDT Changeover As Q555.2 with Early ON on a select day

Q550 Astro

Part No.

Description

• Automatically adjusts its self to sunset and sunrise times without need for a sensor. • 20A rated 24 hour SPST time switch. • 100 hour battery reserve. • Up to 3,600W of LED lighting. • Find your correct Zone below.

E854 E855

3-pin with up to 48 on/off operations 4-pin with up to 48 on/off operations

Part No. Description 3-Pin with Sunset/Sunrise Operations, Day Omit Skips ON Operation Q550.13.11 Zone 1 Q550.13.12 Zone 2 Q550.13.13 Zone 3 Q550.13.14 Zone 4 3-Pin with Sunset/Sunrise Operations & Optional Early Off Q551.13.11 Zone 1 Q551.13.12 Zone 2 Q551.13.13 Zone 3 Q551.13.14 Zone 4 3-Pin with Sunset/Sunrise & Fixed On/Off Operation Q551.14.11 Zone 1 Q551.14.12 Zone 2 Q551.14.13 Zone 3 Q551.14.14 Zone 4 4-Pin with Sunset/Sunrise Operations & Optional Early Off Q553.13.11 Zone 1 Q553.13.12 Zone 2 Q553.13.13 Zone 3 Q553.13.14 Zone 4 4-Pin with Sunset/Sunrise & Fixed On/Off Operations Q553.14.11 Zone 1 Q553.14.12 Zone 2 Q553.14.13 Zone 3 Q553.14.14 Zone 4

182

Together we generate value

Made with FlippingBook - Online magazine maker