Phase Electrical General Catalogue

HEATING & VENTILATION Domestic Ventilation

A

B

Aria

A

• Entry level axial fan for toilets and bathrooms.

• Just 26 dB(A) and IPX4 rated.

Part No.

Description

Flow Rate (l/sec)

Sound Pressure (dB(A))

Power Consumption (W)

Suitable Ducts (mm)

Dimensions (mm)

90000687 90000688 90000689 90000690

Aria 100B – Basic Aria 100T – Timer

18.5 18.5 18.5 18.5

26 26 26 26

6.3 6.3 6.3 6.3

100 100 100 100

150 x 150 x 102 150 x 150 x 102 150 x 150 x 102 150 x 150 x 102

Aria 100HT – Humidity Timer

Aria 100MST – Motion Sensor Timer

iCONstant

B

• The quietest dMEV fan available – suitable for all rooms. • Guaranteed constant volume feature (smart flow sensor).

• The only IPX5 dMEV fan for wall and ceiling installs. • LED self-diagnostics and “fine tune” commissioning option of flow rate.

Part No.

Description

Flow Rate (l/sec)

Sound Pressure (dB(A))

Power Consumption (W)

Suitable Ducts (mm)

Dimensions (mm)

72687117 72687118

iCONstant - Timer

6/8 / 8/13 / 13/20 10/15 / 15/28 / 28/38 1.1/1.2 / 1.2/1.7 / 1.7/2.9 6/8 / 8/13 / 13/20 10/15 / 15/28 / 28/38 1.1/1.2 / 1.2/1.7 / 1.7/2.9

100 100

197 x 197 x 120 197 x 197 x 120

iCONstant - Humidity Timer

Are you a Competent Ventilation Systems Installer? Training Residential ventilation, from a toilet extract fan to a mechanical ventilation with heat recovery system, is ‘notifiable work’ under the latest Building Regulations and every new installation or refurbishment requiring a new electrical circuit should be inspected, commissioned, tested and signed off by a suitably qualified person. Airflow operate the NICEIC approved Domestic Ventilation Systems installer training course which enables participants to demonstrate a high level of competency mapped against relevant National Occupational Standards and the latest Building Regulations affecting residential ventilation. This two-day course comprises both practical “hands-on” system training and a written assessment following an introduction to relevant Building Regulations and supporting documents. • Comprehensive two-day ventilation installer training to the latest Building Regulations.

• Benefits from a Nationally Recognised Qualification. • Add credibility and opportunity to your business. • Understand the use of the correct test equipment. • Successful candidates eligible to join the Competent Persons Ventilation Installer Scheme. For more information visit https://www.airflow.com/niceic-ventilation-installer-training-scheme or contact us on 01494 525252

186