FIRE & SECURITY
Fire Alarm Systems
CFP Conventional Systems LPCB certified to the latest revisions of EN54 parts 2 and 4, the new-look super-enhanced CFP conventional fire panel offers an array of user and installer-friendly features at a very competitive price. Each of the 2, 4, or 8 zone panels available feature four conventional sounder circuits, class change and alert inputs, on-board fire and fault relays and combined keypad/keyswitch entry. • LPCB certified to the latest versions of EN54 Parts 2 and 4. • 2, 4 or 8 zone circuits (dependent on model). • Four conventional sounder circuits. • Integral 1.5A EN54-4/A2 compliant switch mode PSU. • Wide range of engineering functions including zone test, coincidence*, zone delay and non-latching zones*. • Two on-board relays (Fire and Fault). • Two open-collector outputs (Remote & Reset). • ‘Class change’ and alert inputs. • Installer-friendly design accommodates easy first fix and straightforward maintenance. • Attractive flush or surface mountable plastic lid and enclosure - no bezel required. • Low 25mA quiescent current. • End of line units included (one per zone). • Ancillary system expansion connections provided for up to eight two-wire repeaters (one CFP761 network driver card required per system) and optional CFP relay boards. AlarmSense ® Bi-Wire System The new Pulse2 AlarmSense ® range consists of a series of conventional, 2, 4 & 8 zone fire alarm control panels designed and approved in accordance with European standards BS EN54- 2 and BS EN54-4 Fire Detection and Fire Alarm systems - Control and Indicating Equipment. • Fully certified to BS EN54-2 and BS EN54-4. • Allows systems to be installed in accordance with BS5838: Part 6. • 2 wire systems, reduces installation cabling. • 2-wire repeaters and ancillary boards via serial bus. • Fully programmable using simple menu options. • Zonal sounder delay for detectors only. • Zonal sounder delay for call points only. • Coincidence output via ancillary board. • Short circuit fire selectable by zone. • Non latching selection by zone. • Silent zones (common sounder outputs). • Zone input delay for sprinkler system connection. • AlarmSense ® local alarm feature supported. • Simple, single board construction. • Installer friendly. • Compatible with all AlarmSense ® devices. • Two conventional monitored sounder outputs. • 3 Amp power supply. • Adjustable sounder delay time. • Sounder configuration options.
Part No.
Description
Part No. Description EN54-23 Visual Alarm Devices (VAD’s) AV-1040 Wall Sounder/Beacon - Red Body, White Flash
Panels
P-3032 P-3033 P-3034
2 Zone CFP Conventional Control Panel 4 Zone CFP Conventional Control Panel 8 Zone CFP Conventional Control Panel
SBE-2003
Wall Beacon - Red Body, White Flash Ceiling Beacon - White Body, White Flash
BAT-3002 Detectors SD-1000 SD-1001 SD-1002 SD-1005 SD-1006
3.4AH Batteries (x2 Required)
SBE-2002
S65 Optical Smoke Detector S65 Ionisation Smoke Detector S65 Rate of Rise 57’c A1R Heat Detector S65 Static 90’c Heat Detector
Call Points CP-1000 CP-1001 CP-1003 Bells BEL-1015
Universal Call Point
Call Point Glass (pack of 10) Call Point Protective Cover
S65 Diode Base
6 Inch Red Bell
Sounders / Beacons SDR-3001
Roshni Sounder
AV-1009
Solista Sounder / Beacon (VID)
Part No. Panels AS-3000 AS-3001 AS-3002 SD-6013 BAT-3003
Description
Part No.
Description
Detectors SD-6000
2 Zone Pulse Control Panel 4 Zone Pulse Control Panel 8 Zone Pulse Control Panel
Optical Smoke Detector + Sounder + Beacon (VID) Heat Detector A1 + Sounder + Beacon (VID) Optical Smoke Detector + Sounder
SD-6002
Relay Module (1A 30v)
SD-6004 SD-6005 SD-6007 SD-6009 SD-6011
7.0AH Batteries (x 2 Required)
Heat Detector A1 + Sounder Optical Smoke Detector
Sounders / Beacons SD-6014
Sounder Base
Heat Detector A1
SD-6015 SD-6018 SD-6019
Sounder / Beacon Base (VID)
Detector Base
Open Area Sounder
Call Points SD-6022 AD-2070
Open Area Sounder / Beacon (VID)
Call Point
Call Point Protective Cover
225
Together we generate value