FIRE & SECURITY Fire Alarm Systems TWINFLEX ® pro2 Bi-Wire System The TwinflexPro² panel is an intelligent 2-wire panel that utilises a conventional type cabling format. The system is classed as Analogue non-addressable due to the architecture used within the design. The devices communicate with the control panel using the Twinflex data protocol.
The TwinflexPro² panel is available in 2,4 & 8 zone variants which support up to 32 Twinflex devices per circuit. The TwinflexPro² is able to recognise and separately identify between smoke detector, heat detector and a manual call point alarm. • Available in 2, 4, and 8 zone panel versions. • Ability identify between smoke detector, heat detector and a manual call point alarm. • Event log storing up to 500 events. • Up to 32 devices per zone. • Allows detectors and sounders to be installed on the same pair of wires. • Day/night mode. • Alarm confirmation and delay programming options. • With the addition of a conventional zone card, a 4 or 8 zone panel can now be configured to accept conventional devices on zones 5 to 8. • Incorporates Integral power supply unit. Addressable Alarm Systems • 1, 2, 4 or 8 Loop formats. • Up to 254 devices per loop (Protocol dependent). • True peer-to-peer networking. • Networkable up to 200 nodes. • Supports intelligent/programmable remote terminals, BMS interface, IP Gateway and I/O Drivers. • Circuit monitoring of local panel circuits. • Autolearn and Loop detection. • Simple Select & Click programming. • 1000 event log entries. • Simplified logic delivers click and go configuration. • Built in voltage and current meters. • Quick start and protect - a working system after an Autolearn is performed. • Single area false alarm management. • Optional Peripheral expansion card. • Programmable logo on screen. • Compatible with Apollo Discovery and XP95, Argus Vega, Hochiki ESP and Nittan Evolution protocols. • Approved to EN54 parts 2 and 4. • Up to 1000 fire detection zones. • Up to 188,800 devices per network.
Part No.
Description
Part No.
Description
Panels
Sounders / Beacons FC-3017
FC-3035 FC-3036 FC-3037 BAT-3002 Detectors FC-3046 FC-3047 FC-3048
2 Zone TWINFLEXpro2 Control Panel 4 Zone TWINFLEXpro2 Control Panel 8 Zone TWINFLEXpro2 Control Panel
Red Hatari Sounder
FC-3019 Call Points FC-3034 FC-3026
Flashpoint Sounder + LED Beacon (VID)
3.4AH Batteries (x 2 required)
Call Point - Resettable
Call Point Cover
ASD Multi-Point Detector
ASD Multi-Point Detector & Sounder ASD Multi-Point Detector, Sounder & Beacon
Part No.
Description
Part No.
Description
Panels
Sounders / Beacons AD-2016
AP-1000 AP-1014 AP-1019 ADI-2025 Detectors AD-2000 AD-2002 AD-2005
1 Loop Addressable Panel 2 Loop Addressable Panel 8 Loop Addressable Panel Intelligent Input / Output Unit
Sounder Base & Isolator
AD-2018 AD-2072 AD-2037 AD-2038 AD-2031 Call Points AD-2068 AD-2070
Sounder / Beacon Base & Isolator (VID) Sounder / Beacon Base & Isolator (VAD)
Wall Sounder & Isolator
Wall Sounder / Beacon + Isolator (VID)
Optical Smoke Detector
Wall Beacon + Isolator (VID)
Heat Detector Detector Base
Call Point & Isolator
Call Point Protective Cover
226
Together we generate value