Phase Electrical General Catalogue

CABLE & CABLE ACCESSORIES

Cable

General Wiring

6491B • See 6491X cables

6181Y

6243Y • Similar to 6242Y but used for Two Way Switching where the extra conductor is required. • Grey sheath. • BS6004. • Voltage rating 300/500V.

• Often known as “Meter Tails” mainly used to connect the Installation to the Electricity providers meter. • BS6004. • Voltage rating 300/500V.

for application but 6491B offers better performance with regards to giving off lower levels of smoke and corrosive gases where a fire may occur.

Part No. Available Sizes mm 6181Y 1.0, 1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0 & 35.0

• BS7211.

6242Y

Part No.

Available Sizes mm

Part No.

Available Sizes mm

6241Y • Not commonly used but can be suitable when an additional double sheathed conductor is required in addition to 6243Y. • BS6004. • Voltage rating 300/500V. • Mainly found in domestic installations as predominantly used for the wiring of houses or where surface mounted cable is required. Offers little protection from damage if not protected. • BS6004. • Voltage rating 300/500V. Part No. 6242Y

6243Y

6491B

1.0 & 1.5

1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0 & 95.0

6242B • See 6242Y for applications but 6242B offers better performance with regards to giving off lower levels of smoke and corrosive gases where a fire may occur. • BS7211.

6491X • Single Insulated Cables that are

Available Sizes mm

normally installed in either plastic or metal conduit or trunking to offer protection for multiple circuits.

1.0, 1.5, 2.5, 4.0, 6.0, 10.0 & 16.0

• BS6004.

Part No.

Available Sizes mm

Part No.

Available Sizes mm

Part No.

Available Sizes mm

6491X

1.5, 2.5, 4.0, 6.0, 10.0, 16.0, 25.0, 35.0, 50.0, 70.0 & 95.0

6242B

6241Y

1.0, 1.5, 2.5, 4.0, 6.0, 10.0 & 16.0

1.0 & 1.5

Fire Resistant Cables Multicore Fire Resistant Cables • A high specification range of cables used to offer protection from fire. Fire Alarm cables are used for the wiring of actual fire alarm systems as well in some cases Emergency Lighting. The cable undergoes rigorous tests to ensure it does not deteriorate and fail within strict time and condition tests to enable occupants to evacuate the building.

Tri-Rated Cables

SWA Cables

Single Core Stranded Copper Tri-Rated Cable • Available in many colours and used very widely by panel builders where the 105degree PVC insulation gives more

694_X & 694_B Steel Wire

Armoured Cable • SWA, stands for Steel Wired Armour as this is the method used to protect the cable from accidental damage, Commonly used when buried in the ground or for surface mounted where more protection is required above 6242Y for example.

protection to ambient heat and the numerous colour choices aid identification.

Part No. TRI0.75 TRI1.0 TRI1.5 TRI2.5 TRI4.5 TRI6.0

Available Sizes mm

0.75

Part No. Standard

Part No. Low Smoke

Available Sizes mm 1.5, 2.5, 4.0, 6.0, 10.0 & 16.0 1.5, 2.5, 4.0, 6.0, 10.0 & 16.0 1.5, 2.5, 4.0, 6.0, 10.0 & 16.0 1.5, 2.5, 4.0, 6.0, 10.0 & 16.0

Cores

1.0 1.5 2.5 4.5 6.0

Size mm

Cores

Available Sheath Colour

6942X 6942B

2

1.5 2+E 2.5 2+E 1.5 3+E 2.5 3+E 1.5 4+E 2.5 4+E

Red, White & Black Red, White & Black Red, White & Black Red, White & Black Red, White & Black Red, White & Black

6943X 6943B

3

TRI25 TRI35 TRI50 TRI70

25.0 35.0 50.0 70.0

6944X 6944B

4

6945X 6945B

5

5