Mountz Sample Calibration Certifications

Calibration Certificate Certificate No. 736020 68135 Mountz Cal ID:

www.mountztorque.com

# AC-1346

Calibration Performed By: MOUNTZ ALABAMA 19051 UNDERWOOD RD. FOLEY, AL 36535 USA (408) 850-9978

Issued To:

19051 UNDERWOOD RD. FOLEY, AL 36535 USA MOUNTZ ALABAMA

Sales Order Number: SO265463

Equipment Tested:

Cal. Date:

6 MONTHS 04-Aug-2025 04-Feb-2025

Description:

MOUNTZ LTT-50I TORQUE ANALYZER ELECTRONIC

Cal. Interval:

Arrival Condition: Cal. Due Date:

Serial Number: Model Number:

LTT1106023

MEETS MFG SPEC

LTT-50I

F Service Performed: CAL TO MFG SPEC / Temp. / RH%: 70 42

Range:

5 - 50

Unit of Measure: lbf.in

Calibration Result:

0.13% PASS

Accuracy:

1% of reading from 10-20%FS 0.5% of reading from 20-100%FS

Uncertainty: Procedure:

3WI-7.1-003

Calibration Notes:

Calibrated using version 2.5.2.5. rev 1.23. Gain checked. A/D count reading: +20

Measurement Data:

Seq.

Description

Nominal

Tolerance -

Tolerance +

As Found As Left

1 2 3 4 5 6 7 8 9

CW 10% Reading 1 CW 10% Reading 2 CW 10% Reading 3 CW 50% Reading 1 CW 50% Reading 2 CW 50% Reading 3 CW 100% Reading 1 CW 100% Reading 2 CW 100% Reading 3 CCW 10% Reading 1 CCW 10% Reading 2 CCW 10% Reading 3 CCW 50% Reading 1 CCW 50% Reading 2 CCW 50% Reading 3 CCW 100% Reading 1 CCW 100% Reading 2 CCW 100% Reading 3

4.9941 4.9941 4.9941 24.9704 24.9704 24.9704 49.9408 49.9408 49.9408 4.9941 4.9941 4.9941 24.9704 24.9704 24.9704 49.9408 49.9408 49.9408

4.9441 4.9441 4.9441 24.7207 24.7207 24.7207 49.4414 49.4414 49.4414 4.9441 4.9441 4.9441 24.7207 24.7207 24.7207 49.4414 49.4414 49.4414

5.0440 5.0440 5.0440 25.2201 25.2201 25.2201 50.4402 50.4402 50.4402 5.0440 5.0440 5.0440 25.2201 25.2201 25.2201 50.4402 50.4402 50.4402

5.0110 5.0028 5.0055 25.0242 25.0269 25.0296 50.0167 50.0194 50.0249 4.9669 4.9641 4.9669 25.0112 25.0139 25.0084 50.0168 50.0389 50.0244

5.0110 5.0028 5.0055 25.0242 25.0269 25.0296 50.0167 50.0194 50.0249 4.9669 4.9641 4.9669 25.0112 25.0139 25.0084 50.0168 50.0389 50.0244

10 11 12 13 14 15 16 17 18

Standards Used:

Description

I.D.

Range

Units Accuracy

Cal. Due

Traceability #

WEIGHT SET 2 CLASS F PRIMARY STANDARD

10041 .016 - 50

lb in

0.01% 0.05%

03-Apr-2025 24-023 24-024 24-025

MOUNTZ W4.0 PRIMARY STANDARD RADIUS WHEEL 73354 4

08-Oct-2026

724448

Work Performed By: T. HOLLEY TECHNICIAN

Reviewed By: CALIBRATION QC A. RHODES

Calibrations are performed using standards traceable through NIST or other National Metrology Institute to the International System of Units (SI). Calibration system complies with ANSI/NCSL Z540-1 and ISO17025. This information applies only to the instrument identified above and may not be reproduced, except in full, without prior written consent. Reported uncertainties are expressed as expanded values at approximately 95% confidence level using coverage factor K=2. There is no implied warranty that instrument will maintain its specified tolerance during the calibration interval. Decision Rule 1 is employed (measurement uncertainty is not taken into account) when making conformity statements unless otherwise specified .

Page 1 of 1

Made with FlippingBook Annual report maker