ADAM-6000 Advantech

15-2

Product Introduction

Ethernet I/O Modules: ADAM-6000/6200/6300 Introduction Advantech's ADAM-6000/6200/6300 Ethernet I/O modules are easily integrated so they can remotely monitor and control devices more flexibly.

Feature Highlights Simple and intuitive logic control

Communication with IoT protocols The ADAM-6000/6200 series supports multiple protocols for IoT applications: MQTT, SNMP, Restful APIs, and Modbus, which are very flexible and can be easily integrated with Microsoft Azure, Database, Network and SCADA systems.

Advantech’s ADAM-6000/6200 Peer-to-Peer (P2P) and Graphic Condition Logic (GCL) modules can perform as standalone products for measurement, control, and automation.

Peer-to-Peer(P2P) connection ƒ Easy channel mapping from different I/O modules without extra programming effort or additional controllers. ƒ Utilizes Peer-to-Peer modules, just configure settings through ADAM.NET utility. Graphic condition logic (GCL) ƒ GCL function is built-in ADAM-6000 and ADAM-6200 modules for users to easily set up logic rules in any application. ƒ User defined logic rules through graphical configuration environment in ADAM.NET utility. ƒ No additional controllers or programming is needed.

Cloud ƒ Supports Azure IoT Hub MQTT ƒ Actively publish MQTT messages with user defined intervals. ƒ Shortens downtime with alarm event notification. ƒ Privacy assured with the TLS (Transport Layer Security). ƒ User defined topic to integrate existing systems. SNMP ƒ Simple way to monitor I/O data on NMS (Network Management System). ƒ SNMP trap to notify alarm events. ƒ Reduces implementation cost with ADAM MIB (Management Information Base) file.

Communication interface

Industrial design / isolation & wide-operating temp.

Flexible deployment with daisy chain networking and auto-bypass protection ADAM-6200/6300 series supports daisy chain connectivity that offers flexible cabling and space saving capabilities. With Ethernet auto-bypass function supported to prevent accidental power failures if one of the modules unexpectedly shuts down.

ADAM-6000/6200/6300 series has a rugged design. ƒ Supports isolation protection to avoid system damage from high-energy noise. ƒ Supports operating temperatures of between -40 ~70°C and can perform in most harsh environments.

ADAM-6000/6200/6300 Series Comparison

Application Structure

ADAM-6000 Series

ADAM-6200 Series

ADAM-6300 Series

Azure

SCADA / NMS

Series Name

AWS

Database

Daisy-chain Connectivity

Ethernet

MQTT

SNMP

Protocols

Modbus

RESTful

Analog Input

Analog Output

Digital Input Digital Output

OPC UA

Pressure Valve

Humidity

Temperature

Vibration

Level

ON/OFF

Light Switch

Made with FlippingBook - Online magazine maker