15-3
Selection Guide
Ethernet I/O Modules: ADAM-6000/6200
SKY Servers 3 2 Intelligent Systems 1 IIoT Software Solutions
8 9 7 6 5 4
) ADAM-6015
) ADAM-6017
) ADAM-6018+
) ADAM-6022
) ADAM-6024
Model
1x RJ-45 LAN port, 10/100 Mbps Ethernet
Interface
AI & Advanced Computer Vision
– –
Receiver Only 2 Receiver Only 2
Peer-to-Peer 1
GCL 1
16-bit for analog inputs 12-bit for analog outputs
16-bit for analog inputs 12-bit for analog outputs
16 bit
Resolution
Intelligent HMI and Monitors
7
8
8
6
6
Channels
10 Hz
10/100 Hz
10 Hz
10 Hz
10 Hz
Sampling Rate
±150 mV, ±500 mV, ±1 V, ±5 V, ±10 V, 0 ~ 150 mV, 0 ~ 500 mV, 0 ~ 1 V, 0 ~ 5 V, 0 ~ 10 V 0 ~ 20, 4 ~ 20, ±20 mA
Automation Computers
–
–
±10 V
±10 V
Voltage Input
Intelligent Transportation Platforms
–
–
0 ~ 20, 4 ~ 20 mA
0 ~ 20, 4 ~ 20 mA
Current Input Direct Sensor Input
J, K, T, E, R, S, B thermocouple
Pt, Balco, and Ni RTD
–
–
–
(4 ~ 20mA only)
– – 2
– – 2
Burnout Detection Math. Functions
Mission Critical CompactPCI Platforms
Max. Min. Avg.
Max. Min. Avg.
Max. Min. Avg.
–
–
–
Channels
0 ~ 20, 4 ~ 20 mA @ 15 V DC
0 ~ 20, 4 ~ 20 mA @ 15 V DC
–
–
–
Current Output
13 15 14 16 12 11 10 Utility and Energy Solutions EtherCAT Solutions and Automation Controllers Industrial Communication Remote I/O, Wireless I/O & Sensors Intelligent Edge DAQ Devices Serial Communication Hgh Speed DAQ Solutions Intelligent Motion Control Solutions
– –
– –
– –
0 ~ 10 V DC @ 30 mA 0 ~ 10 V DC @ 30 mA
Voltage Output Input Channels Output Channels High/Low Alarm Settings
2
2
-
2 (sink)
8 (sink)
2 (sink)
2 (sink)
–
–
2,000 V DC
2,000 V DC 3
2,000 V
Isolation Protection
3
DC
Built-in dual loop PID control algorithm
–
–
–
–
Remark
D version: Modbus TCP,RESTful, MQTT, SNMP,ASCII C1D2, UL, CE, FCC
D version :Modbus TCP, RESTful, MQTT, SNMP,ASCII
Modbus TCP
Protocols
C1D2, UL, CE, FCC C1D2, UL, CE, FCC C1D2, UL, CE, FCC
CE, FCC
Certificate
) ADAM-6050
) ADAM-6051
) ADAM-6052
) ADAM-6060
) ADAM-6066
Model
1x RJ-45 LAN port, 10/100 Mbps Ethernet
Interface
Peer-to-Peer 1
GCL 1
12
12
8
6
6
Input Channels Output Channels Extra Counter Channels Counter Input Frequency Input
6 (sink)
2 (sink)
8 (source)
6-ch relay
6-ch power relay
–
2
–
–
–
3 kHz 3 kHz
4.5 kHz 4.5 kHz
3 kHz 3 kHz
3 kHz 3 kHz
3 kHz 3 kHz
Pulse Output
High/Low Alarm Settings
–
–
–
–
–
2,000 V DC
Isolation Protection
D version: Modbus TCP,RESTful, MQTT, SNMP,ASCII
Protocols Certificate
C1D2, UL, CE, FCC C1D2, UL, CE, FCC C1D2, UL, CE, FCC
UL, CE, FCC
UL, CE, FCC
: supported, – : not supported, : optional
Made with FlippingBook - Online magazine maker