Machinery's Handbook, 31st Edition
Standard Tapers
1021
Table 7b. American National Standard Plug and Ring Gages for the Self-Holding Taper Series ANSI/ASME B5.10-1994 (R2013)
L
A ”
A
Gage Line
L
L ”
A ”
Gage Line
A
Depth of Gaging Notch, Plug Gage L ′
Tolerances for Diameter A b
Diameter at Small End A ′
Diameter a at Gage Line A 0.23922 0.29968 0.37525 0.47500 0.70000 0.93800 1.23100 1.50000 1.74800 2.49400
Length Gage Line to End L
No. of Taper
Taper a per Foot
Class X Gage 0.00004 0.00004 0.00004 0.00004 0.00004 0.00006 0.00006 0.00006 0.00008 0.00008 0.00010 0.00008 0.00008 0.00010 0.00010 0.00010 0.00010 0.00013 0.00013 0.00016 0.00020 0.00020
Class Y Gage 0.00007 0.00007 0.00007 0.00007 0.00007 0.00009 0.00009 0.00009 0.00012 0.00012 0.00015 0.00012 0.00012 0.00015 0.00015 0.00015 0.00015 0.00019 0.00019 0.00024 0.00030 0.00030
Class Z Gage
0.239 0.299 0.375
0.50200 0.50200 0.50200 0.59858 0.59941 0.60235 0.62326 0.62400 0.63151 0.62565
0.00010 0.20000 0.00010 0.25000 0.00010 0.31250 0.00010 0.36900 0.00010 0.57200 0.00012 0.77800 0.00012 1.02000 0.00012 1.26600 0.00016 1.47500 0.00016 2.11600 0.00020 2.75000 0.00016 1.703 0.00016 2.156 0.00020 2.609 0.00020 3.063 0.00020 3.516 0.00020 3.969 0.00025 4.422 0.00025 5.328 0.00032 7.141 0.00040 8.953 0.00040 10.766
0.94 1.19 1.50 2.13 2.56 3.19 4.06 4.50
0.048 0.048 0.048 0.040 0.040 0.040 0.038 0.038 0.038 0.038 0.038 0.032 0.032 0.032 0.032 0.032 0.032 0.032 0.032 0.032 0.032
1 2 3 4 5 6 7
4 1 ⁄ 2
5.19 7.25 10.00 4.75 5.50 6.25 7.00 7.75 8.50 9.25 10.75 13.75 16.75 19.75
0.62400 3.27000 0.75000 2.00000 0.75000 2.50000 0.75000 3.00000 0.75000 3.50000 0.75000 4.00000 0.75000 4.50000 0.75000 5.00000 0.75000 6.00000 0.75000 8.00000 0.75000 10.00000 0.75000 12.00000
200 250 300 350 400 450 500 600
800 1000 1200
0.032 a The taper per foot and diameter A at gage line are basic dimensions. Dimensions in Column A ′ are calculated for reference only. b Tolerances for diameter A are plus for plug gages and minus for ring gages. All dimensions are in inches. The amount of taper deviation for Class X, Class Y, and Class Z gages are the same, respectively, as the amounts shown for tolerances on diameter A . Taper deviation is the permissible allowance from true taper at any point of diameter in the length of the gage. On taper plug gages, this deviation may be applied only in the direction that decreases the rate of taper. On taper ring gages, this devi ation may be applied only in the direction that increases the rate of taper. Tolerances on two-deci mal dimensions are ± 0.010. British Standard Tapers.— British Standard 1660: 1972, “Machine Tapers, Reduction Sleeves, and Extension Sockets,” contains dimensions for self-holding and self-releasing tapers, reduction sleeves, extension sockets, and turret sockets for tools having Morse and metric 5 percent taper shanks. Adapters for use with 7 ⁄ 24 tapers and dimensions for spindle noses and tool shanks with self-release tapers and cotter slots are included in this Standard.
Copyright 2020, Industrial Press, Inc.