ANVIL MICROMETERS

773

Measuring Range

Barrel

Measuring Faces

0

0 1

20

Anvil

Spindle

Thimble

Graduations

Frame

Fig. 6. Type I, Class 1, Style D: Upright Anvil Tubing Micrometer. Enameled (I-Beam or Hollow Tubular) Frame.

Finish: The finish of the Type I, Class 2 frames shall be a dull, non-reflective chrome plating. The utile measuring face of the anvil and spindle shall have a finish not to exceed 4 m in Ra. The finish of the outer surfaces of the spindle shall not exceed 32 m in Ra. Type I, Class 2, Style A: The Style A Solid Anvil Micrometer is provided in 0–1 inch, 1–2 inch, and 2–3 inch only. The Style A micrometer shall conform to the tolerance limits as defined in Table 8a and Table 8b and in design appear similar to Fig. 7.

Locking Nut or Clamp Ring

Measuring Range Measuring Faces

Ratchet or Friction Stop

Vernier

Anvil

0

0 1

20

Spindle

32NDS. 1.0312 3.0937 5.1625 7.2187 9.2812

Thimble

1-8.125 1-4.250 3-8.375 1-2.500 5-8.625 3-4.750 7-8.875

Graduations

11.3437 13.4062 15.4687

Barrel

Vernier

16THS. 1.0625 3.1875

17.5312 19.5937

21.6562 23.7187

5.3125

Frame

7.4375

25.7812 27.8437

9.56.25

0

11.6875

29.9062

13.8125

31.9678

15.9375

0

1 2 3 4

20

Graduations

Reference Line

Fig. 7. Type I, Class 2, Style A: Solid Anvil, Finished Frame Micrometer

Type I, Class 2, Style B: The Style B Paper Gage (Disk) Micrometer shall be designed with a disk attached to the anvil and spindle of approximately 0.4375 inch diameter. The Style B micrometer is provided in ranges from 0– 1 ⁄ 2 inch, 0–1 inch, and 1–2 inch. The attached disk may be larger or smaller than recommended diameter. All variations in design shall adhere to the tolerance limits defined in Table 8a and Table 8b. The Style B micrometer shall follow in design and appear similar to Fig. 8.