Dacor Pricebook – Effective October 25, 2024

48-Inch Gas Range TRANSITIONAL

Product Dimensions

Without grate 36" (91.4 cm) Min. 37 ¼" (94.6 cm) Max.

With grate 37 " (94.9 cm) Min. 38 " (98.1 cm) Max.

47 " (121.6 cm)

Installation guide English 11

dimensions

ON rhead cabinets are installed, a range hood should also be installed project horizontally a minimum of 5" (12.7 cm) beyond the front of the nets. Hood is necessary to dissipate any heat buildup in the overhead 8x960Gx_DA_EN+MES+CFR.indb 11 Installation Requirements

Recommended locations for gas piping and electrical outlets

lating hood must be constructed of sheet metal not less than 0.0122"

een the hood and the underside of the combustible material or metal net. The hood must be at least as wide as the appliance and centered over ppliance. Clearance between the cooking surface and the ventilation hood ce must never be less than 24".

48 in (121.9 cm)

ption 1 : Installation of a listed microwave oven or cooking appliance the cooktop shall conform to the installation manual provided with the ance. 48 in (1219 mm) 30 in (76.2 cm)

13 in (33 cm) Overhead Cabinet Depth

Minimum to combustibles (Installation without a hood)

30" (76.2 cm) minimum clearance between the top of the cooking surface and the bottom of an unprotected wood or metal cabinet; or If 30" (76.2 cm) clearance is not possible, minimum of 24" (61 cm) can be used when the bottom of the wood or metal cabinet is protected by not 6 in* (15.2 cm) 6 in* (15.2 cm) 18 in (45.7 cm) 30 in (76.2 cm)

Recommended position for Gas stub

0 in (0 cm) Clearance Below Cooking Top

24 in (61 cm) Lower Cabinet Depth

22.6 in (573.5 mm)

than no. 28 MSG sheet steel, 0.015" (0.038 cm) stainless steel, 0.024" (0.061 cm) aluminum, or 0.020" (0.051 cm) copper. 18" (45.7 cm) of minimum clearance between the countertop and the adjacent cabinet bottom. ption 2 ck edge of countertop and 4" minimum from cutout to side edges of tertop. in (953 mm) and at Rear and Sides of Range * Side clearance above cooking surface to any objects, i.e., wall. 37

0 in (0 cm)

Recommended position for Electrical outlet

B

A

Electrical outlet

A

9 7 / 7 / 8 ’’(H) (25.1 cm x 17.5 cm) Model numbers, specifications and prices are subject to change at any time without notice. Visit dacor.com for the most up-to-date information. | Effective October 25, 2024 8 ’’(W) X 6

DOP48T960GS 48-Inch Gas Range

Gas piping

B

17 15 /

16 " (W) X 5

3 / 8 ''(H) (45.5 cm x 13.8 cm)

Made with FlippingBook - professional solution for displaying marketing and sales documents online