48-Inch Gas Rangetop
27 15/16" (70.9 cm) 27 1/2" (69.9 cm)
27 15/16" (70.9 cm) 27 1/2" (69.9 cm)
25 11/16" (65.3 cm) 22 1/4" (56.5 cm)
25 11/16" (65.3 cm) 22 1/4" (56.5 cm)
36" (91.4 cm)
36" (91.4 cm)
DTT48T960
DTT48T960 Product Dimensions
27 15/16" (70.9 cm) 27 1/2" (69.9 cm)
27 15/16" (70.9 cm) 27 1/2" (69.9 cm)
25 11/16" (65.3 cm) 22 1/4" (56.5 cm)
25 11/16" (65.3 cm) 22 1/4" (56.5 cm)
Installation Requirements
48" (121.9 cm)
In Preparation 48" (121.9 cm)
SIDE VIEW
1.
chassis and anything in the cabinet below.
2. Remove all packing material and accessories from the rangetop, and verify that all items are present before beginning the installation.
Installation Requirements Installation Requirements
Location Requirements Before you begin the installation, review this section thoroughly. These dimensions must be met for safe
Installation Requirements
Countertop Cutout Dimensions
A - RANGETOP CUTOUT (IN/MM)
A - RANGETOP CUTOUT (IN/MM)
48 / 121.9
48 / 121.9
Countertop Cutout Dimensions
Countertop Cutout Dimensions
CAUTION
B - RANGETOP CUTOUT MINIMUM (IN/MM)
48 / 121.9
Cabinet/Countertop Dimensions (front view)
The rangetop complies with the maximum allowable wood-cabinet temperature of 194 °F (90 °C). Ensure the wall covering, countertops, and surrounding cabinets can withstand this temperature to avoid discoloration, delamination, or melting.
Cabinet/Countertop Dimensions (front view)
B - RANGETOP CUTOUT RECOMMENDED (IN/MM)
10” (25.4 cm) to combustible side wall min. both sides
54 / 137.2
10” (25.4 cm) to combustible side wall min. both sides
1 1/2” (3.8 cm) typical countertop thickness
1 1/2” (3.8 cm) typical countertop thickness
1/2” (1.3 cm) overhang, both sides
Maintain These Minimum Clearances
1/2” (1.3 cm) overhang, both sides
1. Vertical to combustible surface from rangetop grate level; if installing a ventilation hood, check hood spec's for minimum required clearances. 2. See Cabinet/Countertop Dimensions -Top View. 3. cabinets more than a horizontal distance of 10" (25.4 cm) from the edge of the rangetop.
English
17
7 3/4” (19.7 cm)
A
English
17
7 3/4” (19.7 cm)
A
Recommended gas and electrical service location, consult local code
Mounting platform 1” (2.5 cm) min. thickness
Recommended gas and electrical service location, consult local code
INSTALL_TOP_DTT48T960_DG68-01476A-00_EN+MES+CFR.indb 17
36” (91.4 cm) typical
Mounting platform 1” (2.5 cm) min. thickness
36” (91.4 cm) typical
INSTALL_TOP_DTT48T960_DG68-01476A-00_EN+MES+CFR.indb 17
FRONT VIEW
Rangetop DTT36T960
DTT48T960
48" (121.9 cm) Installed Rangetop (side view)
A
36" (91.44 cm) Installed Rangetop (side view)
36" (91.44 cm)* 42" (106.7 cm)**
48" (121.9 cm)* 54" (137.2 cm)**
B
24” (61.0 cm)
* Minimum ** Recommended A: Rangetop cutout B: Range hood cutout
24” (61.0 cm)
Installed control panel overhang 1 3/4" (4.3cm)
Installed control panel overhang 1 3/4" (4.3cm)
Countertop
Countertop
Cabinet face
Cabinet face
Mounting platform
Mounting platform
SIDE VIEW
CAUTION
CAUTION
Cutout dimensions must be observed. Any overage could be create severe problems. Cutout dimensions must be observed. Any overage could be create severe problems.
NOTE
NOTE
Cabinet tolerances +1/16" (+1.6 mm) -0 unless otherwise noted. Cabinet tolerances +1/16" (+1.6 mm) -0 unless otherwise noted.
English 16
INSTALL_TOP_DTT48T960_DG68-01476A-00_EN+MES+CFR.indb 16
Model numbers, specifications and prices are subject to change at any time without notice. Visit dacor.com for the most up-to-date information. | Effective October 25, 2024
English 18
DTT48T960G 48-Inch Gas Rangetop
English 18