S80 GLASS/S80 GLASS SC FOR SLIDING INTERIOR DOORS
ASSEMBLY INSTRUCTIONS
1
Various installation options
Ceiling mounting
Side mounting
Side mounting with extended profile
3
31
8-12 8-12 31
55
60 50
50 - tl./2
H
Installation of upper leading rail and lower guide – Set S80 Glass
Hs
2
3
Drilling scheme
55
Depending on the weight of the door wing, the holders are mounted approx. 500 mm apart
See the drilling detail
10
Profile S40/S80N aluminium
Profile S40/S80 steel
H
Hs
30
30
30
M8
M8
10
Th 10 mm Note: screw tightening torque 15 Nm Glass drilling detail
20
Ø 15
65
min. 35
20
Ø 15
65
min. 35
8/10/12
Use only for tempered glass up to 45 kg A rubber seal (part of the set) must be inserted in the holder
Mounting the upper rail Slide the runners and brakes into the rail before mounting them Secure the brakes in the required place depending on the location of the upper runner
Inner diameter = H Aluminium – door high: Hs = H - min. 65 Steel – door high: Hs = H - min. 61 Glass thickness: 8/10/12