Mold Bases & Plates

Standard & Optional Mold Base Features

164

Insulator Sheets

DME High Temperature Insulator Sheets are used on molds and dies between the top clamping plate and the stationary platen, and between the bottom of the ejector housing and the movable platen.

• Asbestos-free material • High compression strength • Machinable with high-speed cutting tools

ENERGY SAVINGS

1 / 4 THICK = 27,508 BTU/HR 1 / 2 THICK = 31,004 BTU/HR

General Data

49,400 PSI AT 75°F 27,200 PSI AT 300°F 18,000 PSI AT 400°F 17,100 PSI AT 500°F 15,000 PSI AT 550°F 1.8 x 10° PSI AT 75°F 2.9 x 10° PSI AT 425°F

COMPRESSIVE STRENGTH

(ASTM D-229)

MODULUS OF ELASTICITY IN COMPRESSION

(ASTM D-229

WATER ABSORPTION

(ASTM D-229)

0.2%

THERMAL CONDUCTIVITY (K FACTOR), (BTU/HR/FT 2 /IN/°F)

1.9 AT 75°F 2.1 AT 425°F

(ASTM C-177)

FLAME RESISTANCE

(UL SUBJECT 94)

94V-0

EXPANSION ACROSS THICKNESS EXPANSION ACROSS SURFACE

6.43 x 10 -5 IN/IN/°F 1.24 x 10 -5 IN/IN/°F

MAXIMUM RECOMMENDED SERVICE TEMPERATURE

550°F

High Temperature Insulator Sheets

THICKNESS LENGTH WIDTH

NET WEIGHT

ITEM NUMBER

18"

HTIS-1836-2

12

1 /

36"

24"

HTIS-2436-2

16

4

36" 48" 18" 24" 36"

HTIS-3636-2 HTIS-4896-2 HTIS-1836-4 HTIS-2436-4 HTIS-3636-4

24

1 /

96"

105

4

24 32 48

1 /

36"

2

NOTE: Special sizes available on special order: Max. length = 96", Max thickness = 1", Max. width = 48", Min. thickness = 1 / 8 Installation: Use 1 /

4 -20 flat head screws. Drill and tap base to suit.