2025 Australian Decking Installation Guide

PRESSURE-TREATED FRAMING REQUIREMENTS, GAPPING AND BUTT JOISTS

5 mm (>4.5°C)

3 mm (>4.5°C) 5 mm (<4.5°C)

3 mm (>4.5°C) 5 mm (<4.5°C)

Max. 19 mm

6 mm

Note: a shortened section of joist (verses a full second joist) can also be attached to the main joist (no gap between joists) to serve as the same function as shown here .

NOTES: » This system should not float; it must be attached securely to framing system. » With wood framing, all cut ends should be coated to preserve ends. Refer to local building supplier for what can be used. » When using screws to attach decking to framing, use two screws per every joist. » For added protection to wood framing, use Trex®Protect® Joist and Beam Tape on the top of joists, rim joists, and ledger boards.

Residential <450 mm Commercial: Refer to Span tables on Website

Min. 38 mm

Min. 38 mm

10 NOTE: Construction methods are always improving. Please refer to www.trex.com for the most up-to-date installation requirements.