Condenser Coil Maintenance Pays Off (‘Energy Manager Today’) Richard Fennelly, the Director of Product Development for CoilPod LLC says that there is not a lot of research on how much money can be saved, but all signs point to a significant amount. It is also a distasteful job that often gets pushed aside. The condensers coils that are at the heart of cooling equipment need to be cooled. This cooling is provided by a fan that draws in air. That air carriers minute pieces of debris along for the ride. The vents get clogged and the fan must work harder to do its job. This causes three problems: The fans use more electricity and therefore are costlier to run, they require more service calls and, ultimately, many fail. Often, these failures result in ruined inventory. Addressing this problem leads relatively easy gains. The greatest are “grab and go” type refrigerator units common in delicatessens and convenience stores since they are in high trafficked public areas. Fennelly, whose company offers a new approach to condenser coil cleaning, pointed to statistics compiled by the Food Service Technology Center (FSTC) and presented at the Restaurant Facility Managers Association and Commercial Food Equipment Service Association conferences last year. The estimates, which presumably are based on refrigeration devices the FSTC found in the field, are predicated on an electric rate of $0.11 per kWh. A six-year-old double door merchandiser costs $1,325 per year when dirty. Operating expense is cut to $625 – a reduction of 47 percent – when the coils are cleaned . A large double door fridge (age unspecified) cost $950 per year to run. That cost is shaved by 46 percent, to $433, when the coils are cleaned. The other examples are in the same range. Fennelly said that food service technicians often say that the most common cause of service calls are problems that arise from clogged condenser coil housings. Typically, the approach to cleaning debris is to use a brush, vacuum or wetvac. These steps are a good start but, ultimately ineffective because the problems often are deeper in the apparatus and can’t be dislodged in this way. by Carl Weinschenk / October 18, 2016 (https: / /www.energymanagertoday.com/condenser-coil-maintenance-pays-off)
Normal Critical
180%
No Control 165.35%
128.71%
124.52%
140%
105.49%
Good 100.00%
100%
50%
0%
0%
20%
40%
50%
60%
Tested Model: TSF-23SD. Ambient Temperature: 92°F
Ratio of Condenser Blocked
Energy Consumption Ratio
Made with FlippingBook - Share PDF online