AMS standards you deserve
Eliminator Fume Hood Series
product catalog
MADE IN USA
Since 1975, Air Master Systems has manufactured chemical fume hoods, filtration hoods, and laboratory furniture for the R&D, institutional, industrial, government and biotech markets.
Contents
Eliminator Series
4 4 6 8
Eliminator HP Series High Performance Energy Efficient Hood
Eliminator 100 Series Airfoil Fume Hood
Eliminator 200 Series Double Faced 100 Series Hood
Eliminator 300 Series Thin Wall Hood Eliminator 400 Series Floor Mounted Hood
10 12 14 16 18 20 22 24 26 27 28 29 30 31 32 33 34 34 35 37 40 41 42 46
Eliminator 500 Series ADA Hood (Barrier Free Design)
Eliminator 600 Series Radio Isotope Hood Eliminator 700 Series Perchloric Acid Hood Eliminator 800 Series Flat Front Hood Eliminator 900 Series Demonstration Hood
Eliminator Paint (Spray) Booth
Canopy Hoods
Updraft/Downdraft Hoods
Air Monitor Alarms
Ceiling Enclosures and Finished Backs
Plumbing Accessories
Electrical Accessories and Specifications
Base Cabinets
Flammable and Acid Storage Cabinets
Vacuum Pump Cabinet
Hood Base Frame
Sash Options
Epoxy Resin and Stainless Steel Surfaces Custom Stainless Steel Countertops
Knock Down Hoods
Fume Hood General Design Requirements
Glossary
Note: Images in this catalog are for representation only. For complete product specifications, contact your AMS representative.
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
3
The Eliminator HP Series
The Eliminator HP hood comes standard with all the same features as other Eliminator models, along with some additional innovations to set this hood apart from its competitors.
THE ELIMINATOR HP SERIES
High Performance/Energy Efficient - A Green Alternative
• Powder coat finish • Full frame construction • Shaft drive sash • U.L. listed poly resin liner • Flush-mount airfoil • Knock down capability • LED light with bulbs • Full-length finger lift • Sash sweep • 25.5” interior working depth
33 1/4”
SASH EXTENDS ABOVE 3”
10”
10” DIA STN STL DUCT
SINGLE WEIGHT
27”
COUNTER BALANCE
SASH SWEEP
57 1/4”
U.L. 1805 Classified
48”
29”
28” MAX SASH OPENING
REMOVABLE ACCESS PANEL
• •
60 FPM
Fits through standard door
• 30” Countertop The HP Eliminator is THE hood for remodeling, new construction, or retrofitting.
1 1/4”
12”
3 7/8”
23 1/4”
30”
Superstructure
Worktop
Hood Opening CFM @ 28”*
CFM @ 18”*
Blower Model # BL-HP-48 BL-HP-60 BL-HP-72 BL-HP-96
Shipping Weight
Part Number
SP
W H
D W H D W H
EH-HP-48 48” EH-HP-60 60” EH-HP-72 72” EH-HP-96 96”
56” 33-1/4” 48” 1-1/4” 56” 33-1/4” 60” 1-1/4” 56” 33-1/4” 72” 1-1/4” 56” 33-1/4” 96” 1-1/4”
30” 30” 30” 30”
38” 50” 62” 86”
28” 28” 28” 28”
469 619 769
313 413 513 713
.25 .34 .34 .34
415 490 535 570
1069
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
4
The Eliminator HP Series
The HP model is designed to operate economically while creating a safe work environment without compromising containment. By operating at 60 FPM, air flow across the sash opening results in a 40% savings in fume hood operation costs. Features of the HP Series include:
• Passed ASHRAE 110 AM testing with sash in full open position. • Standard 30” deep work surface for zero work space loss in your lab. Other depths available.
THE ELIMINATOR HP SERIES
60”
48” OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
JUNCTION BOX
EH-HP-48
EH-HP-60
72”
96”
OF EXHAUST DUCT
24”
24”
JUNCTION BOX
OF EXHAUST DUCT
JUNCTION BOX
EH-HP-72
EH-HP-96
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Epoxy Tops Alarms Base Cabinets Blowers Pre-Plumbing
AMS PT#
PAGE #
ITEM
AMS PT#
PAGE #
Sash Stops Chain and Sprocket Drive
SASHSTOP CHNSPK SS SASH SS AF PUSH BUTTON H&V LATTICE
CE
38 CALL 38 38 38 CALL 38
33 34 35 39 32 36 CALL
Stainless Steel Sash Stainless Steel Airfoil Push Button Sash Combination Sash Lattice Assembly
ET ALARM BC BL PREP PREW
Auto Sash Return
Pre-Wiring
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
5
The Eliminator 100 Series The EH-100 series airfoil fume hood features a 45-degree angle around the fascia and a flush-mount radiused airfoil across the bottom, which results in minimized turbulence and increased performance. Like the exterior of the hood, the airfoil is made from chemical-resistant, powder-coated, 16-gauge cold rolled steel. A stainless steel airfoil is available as an option. Posts are 5” (127 mm) wide.
Five standard sizes offer design flexibility, or we’ll customize to your specific needs.
ELIMINATOR 100 SERIES - AIRFOIL FUME HOOD
Airfoil Fume Hood - Minimized Turbulence, Increased Performance
• Powder coat finish • Full frame construction • Shaft drive sash • U.L. listed poly resin liner • LED light with bulbs • Flush-mount airfoil • Knock down capability • Full-length finger lift • Louvered front for by-pass • 10” round S/S duct collar
33 1/4”
SASH EXTENDS ABOVE 5”
LED LIGHT
10”
10” DIA STN STL DUCT
SINGLE WEIGHT
24”
COUNTER BALANCE
57 1/4”
48”
32”
29” MAX SASH OPENING
U.L. 1805 Classified
1 1/4”
9”
3 7/8”
30”
Superstructure
Worktop
Hood Opening CFM @ 29”*
CFM @ 18”*
Blower Model #
Shipping Weight
Part Number
SP
W H
D W H D W H
EH-111-36 36” EH-111-48 48” EH-111-60 60” EH-111-72 72” EH-111-96 96”
56” 33-1/4” 36” 1-1/4” 56” 33-1/4” 48” 1-1/4” 56” 33-1/4” 60” 1-1/4” 56” 33-1/4” 72” 1-1/4” 56” 33-1/4” 96” 1-1/4”
30” 30” 30” 30” 30”
26” 38” 50” 62” 86”
29” 29” 29” 29” 29”
567 833
354 521 688 854
.25 BL-100-36 .25 BL-100-48 .34 BL-100-60 .34 BL-100-72 .40 BL-100-96
320 385 450 510 630
1100 1367 1900
1188
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
6
The Eliminator 100 Series
OF EXHAUST DUCT 36”
48”
60”
OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
JUNCTION BOX
JUNCTION BOX
EH-111-36
EH-111-48
EH-111-60
96”
72”
24”
24”
JUNCTION BOX
OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
EH-111-72
EH-111-96
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Epoxy Tops Alarms Base Cabinets Blowers Pre-Plumbing
AMS PT#
PAGE #
ITEM
AMS PT#
PAGE #
Sash Stops Chain and Sprocket Drive
SASHSTOP CHNSPK SS SASH SS AF PUSH BUTTON H&V LATTICE AUTO RETURN
CE
38 CALL 38 38 38 CALL 38
33 34 35 39 32 36 CALL
Stainless Steel Sash Stainless Steel Airfoil Push Button Sash Combination Sash Lattice Assembly
ET ALARM BC BL PREP PREW
Auto Sash Return
Pre-Wiring
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
7
The Eliminator 200 Series The Eliminator 200 series provides the same aerodynamic design features as the EH-100 airfoil hood series, with entrance from two sides. This makes it ideal for use in classroom or prep room settings. A 45-degree angle around the fascia and a flush-mount radiused airfoil across the bottom provide minimized turbulence and increased performance.
ELIMINATOR 200 - DOUBLE-SIDED 100 SERIES
Double-Sided 100 Series - Dual Access
• Powder coat finish • Full frame construction • U.L. listed poly resin liner • Flush-mount airfoil • Knock down capability • LED light with bulbs • Full-length finger lift • Louvered front for by-pass • 10” round S/S duct collar
35 1/2”
SASH EXTENDS ABOVE 5”
17 3/4”
10” DIA STN STL DUCT
24”
SASH INTERLOCK
REMOVABLE ACCESS PANELS
57 1/4”
32”
29” MAX SASH OPENING
U.L. 1805 Classified
17 3/4”
3 7/8”
3 7/8”
29”
Superstructure
Worktop
Hood Opening CFM @ 29”*
CFM @ 18”*
Blower Model #
Shipping Weight
Part Number
SP
W H
D W H D W H
EH-211-36 36” EH-211-48 48” EH-211-60 60” EH-211-72 72” EH-211-96 96”
56” 35-1/2” 36” 1-1/4” 56” 35-1/2” 48” 1-1/4” 56” 35-1/2” 60” 1-1/4” 56” 35-1/2” 72” 1-1/4” 56” 35-1/2” 96” 1-1/4”
29” 29” 29” 29” 29”
26” 38” 50” 62” 86”
29” 29” 29” 29” 29”
567 833
354 521 688 854
.25 BL-100-36 .33 BL-100-48 .34 BL-100-60 .34 BL-100-72 .40 BL-100-96
400 450 500 550 650
1100 1367 1900
1188
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
8
The Eliminator 200 Series
The EH-200 features standard 5” (127 mm) posts to allow for electrical and remote control plumbing services on both sides, and these can be configured to your exact specifications.
Five standard sizes and an array of options make this one of the most flexible fume hoods available anywhere.
ELIMINATOR 200 - DOUBLE-SIDED 100 SERIES
OF EXHAUST DUCT 36”
48”
60”
OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
JUNCTION BOX
JUNCTION BOX
EH-211-36
EH-211-48
EH-211-60
96”
72”
24”
24”
JUNCTION BOX
OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
EH-211-72
EH-211-96
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Epoxy Tops Alarms Base Cabinets Blowers Pre-Plumbing
AMS PT#
PAGE #
ITEM
AMS PT#
PAGE #
Sash Stops Chain and Sprocket Drive
SASHSTOP CHNSPK SS SASH SS AF PUSH BUTTON H&V LATTICE AUTO RETURN
CE
38 CALL 38 38 38 CALL 38
33 34 35 39 32 36 CALL
Stainless Steel Sash Stainless Steel Airfoil Push Button Sash Combination Sash Lattice Assembly
ET ALARM BC BL PREP PREW
Auto Sash Return
Pre-Wiring
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
9
The Eliminator 300 Series
The Eliminator 300 series is a thin-wall hood with slimmer front posts to expand the workspace. Posts are 2-1/2” (64 mm) wide.
Because the slimmer posts remove the option for wiring and plumbing in the posts, plumbing services must be deck mounted. Optional light and blower switches can be mounted on the post.
Five standard widths with unlimited heights and depths are available.
ELIMINATOR 300 - THIN WALL
Thin Wall - Expanded Workspace
• Powder coat finish • Full frame construction • Shaft drive sash • U.L. listed poly resin liner • LED light with bulbs • Knock down capability • Full-length finger lift • Louvered front for by-pass
29 1/2”
SASH EXTENDS ABOVE 5”
LED LIGHT
10”
10” DIA STN STL EXHAUST DUCT
SINGLE WEIGHT SASH COUNTERBALANCE
25 1/4”
56”
48”
30 3/4”
28” MAX SASH OPENING
U.L. 1805 Classified
1/2”
1 1/4”
30”
Superstructure
Worktop
Hood Opening CFM @ 28”*
CFM @ 18”*
Blower Model #
Shipping Weight
Part Number
SP
W H
D W H D W H
EH-311-36 36” EH-311-48 48” EH-311-60 60” EH-311-72 72” EH-311-96 96”
56” 29-1/2” 36” 1-1/4” 56” 29-1/2” 48” 1-1/4” 56” 29-1/2” 60” 1-1/4” 56” 29-1/2” 72” 1-1/4” 56” 29-1/2” 96” 1-1/4”
30” 30” 30” 30” 30”
26” 43” 55” 67” 91”
28” 28” 28” 28” 28”
646 896
431 597 764 944
.25 BL-300-36 .25 BL-300-48 .39 BL-300-60 .37 BL-300-72 .43 BL-300-96
190 175 200 250 275
1146 1417 1896
1264
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
10
The Eliminator 300 Series
48”
36”
60”
JUNCTION BOX
JUNCTION BOX
JUNCTION BOX
OF EXHAUST DUCT
OF EXHAUST DUCT
OF EXHAUST DUCT
EH-311-36
EH-311-48
EH-311-60
72”
96”
JUNCTION BOX
24”
24”
OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
EH-311-72
EH-311-96
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Epoxy Tops Alarms Base Cabinets Blowers
AMS PT#
PAGE #
ITEM
AMS PT#
PAGE #
Sash Stops Chain and Sprocket Drive
SASHSTOP CHNSPK SS SASH H&V AUTO RETURN LATTICE
CE
38 CALL 38 38 CALL 38
33 34 35 39 32 36 CALL
Stainless Steel Sash Combination Sash Lattice Assembly Auto Sash Return
ET ALARM BC BL
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
11
The Eliminator 400 Series The Eliminator 400 series, with a double-hung sash configuration and 72” high opening, is designed to accommodate a large-apparatus application, up to 85” in height. Posts are 5” (127 mm) wide. Many heights and depths are available. Contact AMS to find the right size hood for your application.
And with the AMS exclusive knock-down ability, even a hood this big is a breeze to install, maintain, repair and move.
ELIMINATOR 400 - FLOOR MOUNTED
Floor Mounted Hoods - For Those Tall Experiments
• Powder coat finish • Full frame construction • Shaft drive sash • U.L. listed poly resin liner • LED light with bulbs • Knock down capability • Full-length finger lift • Louvered front for by-pass
35”
SASH EXTENDS ABOVE 17”
LED LIGHT
11”
10” DIA STN STL DUCTS
19”
SINGLE WEIGHT COUNTERBALANCE FOR EACH SASH
(2) GASKETED ACCESS PANELS
93”
DOWNSPOUT LOCATION
74” * 72” MAX SASH OPENING 72”
85”
DRAIN LOCATION
U.L. 1805 Classified
23 11/16”
Superstructure
Hood Opening
Approx. Shipping Weight
Part Number
CFM@18”
CFM @ 36”* CFM @ 72”* SP Blower Model #
W H
D W H
EH-411-48 48” EH-411-60 60” EH-411-72 72” EH-411-96 96”
93” 93” 93” 93”
35” 35” 35” 35” 35”
38” 50” 62” 86”
72” 72” 72” 72” 72”
445 653 812
990
1979 2613 3246 4513 5780
.25 .34 .50 .34 .58
BL-400-48 BL-400-60 BL-400-72 BL-400-96 BL-400-120
560 675 790
1306 1623 2256 2889
1128 1444
1025 2500
EH-411-120 120” 93”
108”
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
12
The Eliminator 400 Series
48”
60”
JUNCTION BOX
JUNCTION BOX
OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
JUNCTION BOX
96”
72”
24”
24”
OF EXHAUST DUCT
OF EXHAUST DUCT
EH-411-48
EH-411-60
EH-411-72
EH-411-96
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Alarms Blowers Pre-Plumbing
AMS PT#
PAGE #
ITEM
AMS PT# SASHSTOP CHNSPK SS SASH
PAGE #
Sash Stops Chain and Sprocket Drive Stainless Steel Sash Horizontal Hanging Doors
CE
38 CALL
33 34 35 32 CALL
38 38 38
HHD H&V LATTICE RAMP
ALARM BL PREP PREW
Combination Sash Lattice Assembly
CALL CALL
SS Ramp
Pre-Wiring
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
13
The Eliminator 500 Series The Eliminator 500 series is an airfoil-type fume hood designed to meet ADA dimensional guidelines. A 45-degree angle around the fascia and a flush-mount radiused airfoil across the bottom result in minimized turbulence and increased performance. The ADA hood’s airfoil flips back out of the way for cleanup. Under the airfoil is a containment trough to capture accidental spills that may flow over the dished work surface.
ELIMINATOR 500 - ADA DESIGN
ADA Design - Meets ADA Dimensional Guidelines
• Powder coat finish • Full frame construction • Shaft drive sash • U.L. listed poly resin liner
• LED light with bulb • Flush-mount airfoil • Knock down capability • Full-length finger lift • Louvered front for by-pass • Painted steel trough assembly • Sash stop • 1/4 turn ball valves
33 1/4”
SASH EXTENDS ABOVE 5”
LED LIGHT
10”
10” DIA STN STL DUCT
SINGLE WEIGHT COUNTER- BALANCE
24”
GASKETED ACCESS PANELS
57 1/4”
48”
32”
U.L. 1805 Classified
29” MAX SASH OPENING
1 1/4”
3 7/8” 7/8”
30”
Superstructure
Worktop
Hood Opening CFM @ 29”*
CFM @ 18”*
Blower Model #
Shipping Weight
Part Number
SP
W H
D W H D W H
EH-511-48 48” EH-511-60 60” EH-511-72 72” EH-511-96 96”
56” 33-1/4” 48” 1-1/4” 56” 33-1/4” 60” 1-1/4” 56” 33-1/4” 72” 1-1/4” 56” 33-1/4” 96” 1-1/4”
30” 30” 30” 30”
38” 50” 62” 86”
29” 29” 29” 29”
833
521 688 854
.25 BL-500-48 .34 BL-500-60 .34 BL-500-72 .40 BL-500-96
395 450 525 630
1100 1367 1900
1188
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
14
The Eliminator 500 Series
The trough assembly is fabricated from chemical-resistant 16-gauge cold rolled steel. ADA kneespace-configured base cabinets, pictured at right, are available. See page 33 for cabinet options.
ELIMINATOR 500 - ADA DESIGN
48”
60”
72”
JUNCTION BOX
JUNCTION BOX
JUNCTION BOX
OF EXHAUST DUCT
OF EXHAUST DUCT
OF EXHAUST DUCT
18”
18”
10”
12”
12”
EH-511-48
EH-511-60
EH-511-72
* Optional combination sashes shown in drawings. Base frames and cabinets sold separately.
AIR FOIL PIVOTS BACK FOR EASY TROUGH CLEANING
AIR FOIL
EPOXY TOP
1/2”
TROUGH
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Epoxy Tops Alarms Base Cabinets
AMS PT#
PAGE #
ITEM
AMS PT#
PAGE #
PREW CHNSPK SS SASH SS AF
CE
33 34 35 39 32 36
Pre-Wiring
Chain and Sprocket Drive Stainless Steel Sash Stainless Steel Airfoil Push Button Sash
CALL 38
ET ALARM BC ROB BL PREP
PUSH BUTTON AUTO RETURN LATTICE LED
38 38 CALL
Lattice Assembly Auto Sash Return
CALL CALL
Blowers Pre-Plumbing Roll Out Base
LED Lights
Base Frames and Cabinets
36
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
15
The Eliminator 600 Series
The Eliminator 600 Radio Isotope Hood is specifically engineered and built to handle applications involving radiochemicals. It has the same aerodynamic design as the standard airfoil hood, with the added feature of a one-piece stainless steel liner and countertop with radius construction to prevent absorption of radioactive and corrosive chemicals.
ELIMINATOR 600 - RADIO ISOTOPE HOOD
Radio Isotope Hood - For Safe Handling of Radiochemicals.
• Powder coat finish • Full frame construction • Shaft drive sash • LED light with bulbs • Flush-mount airfoil • Interior access to light • Full-length finger lift
• Louvered front for by-pass • 304 stainless steel one-piece integral work surface and liner.
• Stainless steel sash • Stainless steel airfoil
33 1/4”
SASH EXTENDS ABOVE 5”
LED LIGHT
10”
10” DIA STN STL DUCT
SINGLE WEIGHT COUNTER- BALANCE
24”
REMOVABLE ACCESS PANELS
57 1/4”
48”
32”
29” MAX SASH OPENING
U.L. 1805 Classified
1 1/4”
9”
3 7/8”
22 3/4”
30”
Superstructure
Integral Worktop Hood Opening CFM @ 29”*
CFM @ 18”*
Blower Model #
Shipping Weight
Part Number
SP
W H
D W H D W H
EH-613-36 36” EH-613-48 48” EH-613-60 60” EH-613-72 72” EH-613-96 96”
56” 33-1/4” 36” 1-1/4” 56” 33-1/4” 48” 1-1/4” 56” 33-1/4” 60” 1-1/4” 56” 33-1/4” 72” 1-1/4” 56” 33-1/4” 96” 1-1/4”
30” 30” 30” 30” 30”
26” 38” 50” 62” 86”
29” 29” 29” 29” 29”
567 833
354 521 688 854
.25 BL-600-36 .25 BL-600-48 .34 BL-600-60 .34 BL-600-72 .40 BL-600-96
190 560 675 790
1100 1367 1900
1188
1025
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
16
The Eliminator 600 Series
The interior of the hood and integral countertop are fabricated of 304 stainless steel, buffed and polished to a smooth #4 finish. This reduces the chance of chemical buildup and simplifies decontamination. The flush-mount radiused airfoil is also type 304 stainless steel, as is the standard vertical rising sash. A combination sash is available as an option. Five available sizes and many optional accessories meet all your design needs and the end user’s application requirements. ELIMINATOR 600 - RADIO ISOTOPE HOOD
60”
48”
36”
OF EXHAUST DUCT
OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
JUNCTION BOX
JUNCTION BOX
EH-613-36
EH-613-48
EH-613-60
72”
96”
24”
24”
OF EXHAUST DUCT
JUNCTION BOX
OF EXHAUST DUCT
JUNCTION BOX
EH-613-72
EH-613-96
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Alarms Base Cabinets Blowers Pre-Plumbing
AMS PT#
PAGE #
ITEM
AMS PT#
PAGE #
Pre-Wiring
PREW SASHSTOP CHNSPK PUSH BUTTON H&V LATTICE AUTO RETURN
CE
33 34 35 32 36 CALL
Sash Stops Chain and Sprocket Drive
38 CALL 38 38 CALL 38
Push Button Sash Combination Sash Lattice Assembly
ALARM BC BL PREP
Auto Sash Return
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
17
The Eliminator 700 Series The Eliminator 700 Perchloric Acid Hood has the same aerodynamic design as the 100 series, with a 45-degree angle around the fascia and a flush-mount radiused airfoil across the bottom to minimize turbulence and provide increased performance.
ELIMINATOR 700 - PERCHLORIC ACID HOOD
Perchloric Acid Hood - For Safe Handling of Perchloric Acid
• Powder coat finish • Full frame construction • Shaft drive sash • LED light with bulbs • Flush-mount airfoil • Full-length finger lift
• Louvered front for by-pass • 316 stainless steel one-piece integral work surface and liner. • Built-in trough
• Manual washdown • Stainless steel sash • Stainless steel airfoil
33 1/4”
SASH EXTENDS ABOVE 5”
LED LIGHT
10” DIA STN STL DUCT
10”
3/4” I.P.S. PERFORATED PVC PIPE FOR WASHDOWN
24”
SINGLE WEIGHT COUNTER- BALANCE
57 1/4”
32”
48”
29” MAX SASH OPENING
U.L. 1805 Classified
1 1/4”
1 1/2” I.P.S. MALE DRAIN
3 7/8”
TROUGH SLOPES FROM 3”TO 4”
5”
30”
Superstructure
Integral Worktop Hood Opening CFM @ 29”*
CFM @ 18”*
Blower Model #
Shipping Weight
Part Number
SP
W H
D W H D W H
EH-716-36 36” EH-716-48 48” EH-716-60 60” EH-716-72 72” EH-716-96 96”
56” 33-1/4” 36” 1-1/4” 56” 33-1/4” 48” 1-1/4” 56” 33-1/4” 60” 1-1/4” 56” 33-1/4” 72” 1-1/4” 56” 33-1/4” 96” 1-1/4”
30” 30” 30” 30” 30”
26” 38” 50” 62” 86”
29” 29” 29” 29” 29”
567 833
354 521 688 854
.25 BL-700-36 .33 BL-700-48 .34 BL-700-60 .34 BL-700-72 .40 BL-700-96
190 560 675 790
1100 1367 1900
1188
1025
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
18
The Eliminator 700 Series
This hard-working hood also features a built-in trough to capture runoff in washdown procedures where perchloric acid is in use. In addition, there is a manual washdown feature for the areas behind the baffles as well as the duct-collar areas. The interior is fabricated of type 316 stainless steel, integrally welded to a 316 stainless steel work surface, then buffed and polished to a #4 finish. The top is 1-1/4” with a 1/4” dish to retain spills. The airfoil and sash are also made of 316 stainless steel.
The EH-700 is built tough to withstand the daily use of perchloric acid, while keeping the workplace safe.
ELIMINATOR 700 - PERCHLORIC ACID HOOD
36”
48”
60”
OF EXHAUST DUCT
OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
JUNCTION BOX
JUNCTION BOX
WASHDOWN
WASHDOWN
WASHDOWN
EH-716-36
EH-716-48
EH-716-60
72”
96”
24”
24”
OF EXHAUST DUCT
JUNCTION BOX
OF EXHAUST DUCT
JUNCTION BOX
WASHDOWN
WASHDOWN
EH-716-72
EH-716-96
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Alarms Base Cabinets Blowers Pre-Plumbing
AMS PT#
PAGE #
ITEM
AMS PT#
PAGE #
Pre-Wiring
PREW SASHSTOP CHNSPK PUSH BUTTON H&V LATTICE AUTO RETURN
CE
33 34 35 32 36 CALL
Sash Stops Chain and Sprocket Drive
38 CALL 38 38 CALL 38
Push Button Sash Combination Sash Lattice Assembly
ALARM BC BL PREP
Auto Sash Return
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
19
The Eliminator 800 Series A basic fume hood for K-12 educational applications, the EH-800 series is similar in design and construction to the EH- 300 (Thin Wall) hood, but with 5” (127 mm) posts to provide plumbing and electrical fixtures on the face of the hood. This hood has many of the same features found in other AMS hoods, but it is economically priced for secondary school budgets.
ELIMINATOR 800 - FLAT FRONT
Flat Front - Economical School Hood
• Powder coat finish • Full frame construction • Shaft drive sash • U.L. listed poly resin liner • LED light with bulbs • Knock down capability • Full-length finger lift • Louvered front for by-pass • 10” round S/S duct collar
29 1/2”
SASH EXTENDS ABOVE 5”
LED LIGHT
10”
10” DIA STN STL DUCT
SINGLE WEIGHT COUNTER- BALANCE
25”
GASKETED ACCESS PANELS
56”
48”
31”
29” MAX SASH OPENING
U.L. 1805 Classified
1/2”
1 1/4”
9”
30”
Superstructure
Worktop
Hood Opening CFM @ 29”*
CFM @ 18”*
Blower Model #
Shipping Weight
Part Number
SP
W H
D W H D W H
EH-811-36 36” EH-811-48 48” EH-811-60 60” EH-811-72 72” EH-811-96 96”
56” 29-1/2” 36” 1-1/4” 56” 29-1/2” 48” 1-1/4” 56” 29-1/2” 60” 1-1/4” 56” 29-1/2” 72” 1-1/4” 56” 29-1/2” 96” 1-1/4”
30” 30” 30” 30” 30”
26” 38” 50” 62” 86”
29” 29” 29” 29” 29”
567 833
354 521 688 854
.25 BL-100-36 .33 BL-100-48 .34 BL-100-60 .34 BL-100-72 .40 BL-100-96
300 360 440 520 680
1100 1367 1900
1188
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
20
The Eliminator 800 Series
36”
48”
60”
JUNCTION BOX
JUNCTION BOX
JUNCTION BOX
OF EXHAUST DUCT
OF EXHAUST DUCT
OF EXHAUST DUCT
EH-811-36
EH-811-48
EH-811-60
72”
96”
JUNCTION BOX
24”
24”
OF EXHAUST DUCT
OF EXHAUST DUCT
JUNCTION BOX
EH-811-72
EH-811-96
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Epoxy Tops Alarms Base Cabinets Blowers Pre-Plumbing
AMS PT#
PAGE #
ITEM
AMS PT# PREW SASHSTOP
PAGE #
CE
33 34 35 39 32 36 CALL
Pre-Wiring Sash Stops
38 CALL 38 38 38 38 CALL
Chain and Sprocket Drive Stainless Steel Sash Push Button Sash
CHNSPK SS SASH PUSH BUTTON H&V AUTO RETURN LATTICE
ET ALARM BC BL PREP
Lattice Assembly Auto Sash Return Combination Sash
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
21
The Eliminator 900 Series The EH-900 series is an educational viewing fume hood with one slimmed down (2” or 51 mm) front post and one standard (5” or 127 mm) post to allow for more workspace and electrical services. Plumbing service must be deck mounted. The EH-900 is available in either right-hand or left-hand orientation. This hood features a two-sash configuration and a third (end) viewing window, making it ideal for use in high schools or any environment where demonstration of experiments is desired. The end window may be eliminated for through-wall installations.
ELIMINATOR 900 - DEMONSTRATION HOOD
Demonstration Hood - Three Windows for Optimum Viewing
• Powder coat finish • Full frame construction • U.L. listed poly resin liner • LED light with bulbs • Knock down capability • Full-length finger lift • Louvered front for by-pass • 10” round S/S duct collar • Sash interlock
30”
SASH EXTENDS ABOVE 11”
10” EXHAUST DUCT
15”
LED LIGHT
18”
SASH INTERLOCK
48”
30”
26 1/2” MAX SASH OPENING
U.L. 1805 Classified
LOWER EXHAUST SLOT
1”
1”
1 1/4”
Superstructure
Worktop
Hood Opening CFM @ 26.5”*
CFM @ 18”*
Blower Model #
Shipping Weight
Part Number
SP
W H D W H D W H
EH-911-60 60”
48”
30”
60” 1-1/4”
32”
53” 26.5”**
1030
722
.75 BL-900-60
500
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
22
The Eliminator 900 Series
60”
30”
9 1/2”
OF EXHAUST DUCT
VIEWING WINDOW
1”
1”
EH-911-60L (switches on left as shown) EH-911-60R (switches on right; not shown)
To order without a viewing window, please add -OEW to the part number
60”
11”
16”
10”
1.25”
4”
3.875”
5.875”
32”
32”
1.125” DIA HOLE FOR CW
0.875” DIA HOLE FOR GAS
3X6 CUPSINK
0.25” DISH
R0.750 TYP
2” DIA HOLES 2-PLACES
3.250”
Accessories Ceiling Enclosures ITEM Plumbing Accessories Electrical Accessories Epoxy Tops Alarms Base Cabinets Blowers Pre-Plumbing
AMS PT#
PAGE #
ITEM
AMS PT#
PAGE #
PREW SASHSTOP SS SASH PUSH BUTTON H&V AUTO RETURN LATTICE
CE
33 34 35 39 32 36 CALL
Pre-Wiring Sash Stops
38 38 38 38 38 CALL
Stainless Steel Sash Push Button Sash Combination Sash Lattice Assembly Auto Sash Return
ET ALARM BC BL PREP
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
23
The Eliminator Paint (Spray) Booth The AMS Paint Booth is fabricated of 18-gauge steel with a corrosion resistant, powder coat baked epoxy finish. The upper booth enclosure includes a standard vapor-proof light as well as two filters set in an easy-to-change flange bracket system. The globed interior light is mounted with bulb included.
ELIMINATOR PAINT (SPRAY) BOOTH
OPTIONAL BLOWER
TRANSITION BY AMS WHEN BLOWER IS SUPPLIED
VAPOR PROOF LIGHT
4”
10”
FILTERS
12” Diameter Turntable Sold separately Part No. TT12CR
48”
34”
1 1/2”
1 1/2”
23 1/2”
BOOTH SIZE
Paint (Spray) Booth
Explosion-Proof Options
CFM @ 100 FPM
CFM @ 100 FPM
Part Number
Description
Part Number
Description
AMS-24-XPB AMS-30-XPB AMS-36-XPB AMS-48-XPB AMS-60-XPB
24” Booth w/X-P Light 30” Booth w/X-P Light 36” Booth w/X-P Light 48” Booth w/X-P Light 60” Booth w/X-P Light
472 613 755
AMS-24-PB AMS-30-PB AMS-36-PB AMS-48-PB AMS-60-PB
24” Paint (Spray) Booth 30” Paint (Spray) Booth 36” Paint (Spray) Booth 48” Paint (Spray) Booth 60” Paint (Spray) Booth
472 613 755
1040 1322
1040 1322
Paint (Spray) Booth w/ Blower
Paint (Spray) Booth w/ Explosion-Proof Light/Blower
CFM @ 100 FPM
CFM @ 100 FPM
Part Number
Description
Part Number
Description
AMS-24-PBW 24” Booth and Blower AMS-30-PBW 30” Booth and Blower AMS-36-PBW 36” Booth and Blower AMS-48-PBW 48” Booth and Blower AMS-60-PBW 60” Booth and Blower
472 613 755
AMS-24-XPBW 24” Booth w/X-P Light and Blower AMS-30-XPBW 30” Booth w/X-P Light and Blower AMS-36-XPBW 36” Booth w/X-P Light and Blower AMS-48-XPBW 48” Booth w/X-P Light and Blower AMS-60-XPBW 60” Booth w/X-P Light and Blower
472 613 755
1040 1322
1040 1322
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
24
The optional blower motor operates at an RPM designed to provide 100 LFM and approximately 3⁄4” of static pressure. If the blower is ordered, it will be mounted on the booth and wired to the common junction box with the light. The transition piece from the booth to blower will be provided and connected. Both the light and the blower can be pre-wired to switches The Eliminator Paint (Spray) Booth
in the front post area of the booth when required. ELIMINATOR PAINT (SPRAY) BOOTH
60”
24”
36”
12 1/2”
6 3/8”
6 3/8”
AMS-24-PB
AMS-36-PB
AMS-60-PB
30”
48”
6 3/8”
10 3/8”
AMS-30-PB
AMS-48-PB
NOTE: Explosion-proof (X-P) switches must mount on the exterior of booth or be shipped loose for remote operation.
Accessories
Light Switch ITEM
AMS PT#
PAGE #
ITEM
AMS PT#
PAGE #
LTSW BLSW
CALL
35 35 39
Galvanized Top Pre-Wire Service
Blower Switch Stainless Steel Top
PREWIRE
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
25
Canopy Hoods AMS canopy hoods are designed to collect and exhaust heat, steam and odors when mounted above hot plates, water baths or portable equipment. They are available in three different models as pictured here and in six standard widths: 24”, 30”, 36”, 48”, 60”, and 72”. Custom sizes are also available. Standard canopy hoods are available in 18-gauge cold rolled steel, finished with acid wash and powder coat epoxy paint. (See inside back cover for available standard colors.) Stainless canopy hoods are fabricated of 18-gauge 304 stainless steel with a #4 smooth grain finish. Two stainless steel threaded rods come with FS and SE models; four are supplied with IL models. CANOPY HOODS
VERIFY COLLAR SIZE AND LOCATION
Ordering Canopy Hoods:
Part Number
Description
CH-FS
Flat back & flat sides
CH-IL
Center style
CH-SE
Flat back and sloped sides
*For Stainless Steel Construction use the prefix -SS
VARIES
Example:
Flat Back & Sides
6”
Depth
CH-FS-4824-SS
2”
2”
Stainless Steel
Width
VARIES
CANOPY HOOD w/ FLAT BACK & FLAT SIDES - “F5” STYLE
CANOPY HOOD - “SE” STYLE
CENTER CANOPY HOOD - ISLAND “IL” STYLE
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
26
Updraft/Downdraft Hoods Inexpensive hoods designed to increase operator safety by ridding fumes such as formalin, smoke or any other non-hazardous media. Many sizes are available; please contact your Air Master Systems representative for further information. SINGLE-SIDED DOWNDRAFT HOOD
10”
3 1/2”
16”
2”
18”
18”
SCREEN (BY OTHERS)
COUNTERTOP
2”
1 3/4”
EXHAUST DUCT CONNECTION BY MECHANICAL LOCATE AS REQUIRED
2”x12” EXHAUST OUTLET BY MECHANICAL
10”
DOUBLE-SIDED DOWNDRAFT HOOD
ADJUSTABLE TOP & BOTTOM BAFFLES
29”
21”
2”
2”
3/4”
22”
22”
12 1/4”
4”
COUNTERTOP
2”
3/4”
EXHAUST DUCT CONNECTION BY MECHANICAL LOCATE AS REQUIRED
2”x12” EXHAUST OUTLET BY MECHANICAL
29”
SINGLE-SIDED UPDRAFT HOOD
2 3/4”
16”
4”x6” OUTLET
2”
18”
BAFFLE
10”
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
27
Air Monitor Alarms
AFA 500 MK3 FUME HOOD AIRFLOW MONITOR
Alarm Range 30-400 fpm (.15 - 2.0 m/s) Accuracy Face velocity accuracy +/- 10% Airflow Sensor On-board or remote sensor Calibration Single or 2-point (Installer Selectable)
Low Air Alarm Delay Fixed 5 seconds Relay Output 1 --( Low Air Alarm) Analog Output Not Available
Relay Input 2 - Night setback and sash high Comm. Port RS232 - Can be connected via serial interface to LAN network (Full hood performance software reporting available) Sash Height Indication Yes - using a micro switch or Proximity switch input. With repeat alarm feature factory set to 5 minutes. (Can be adjusted via laptop up to 30 min.) Night Setback Yes - using a relay input External Alarm Indication Not available Power Requirement Input - 120VAC, 60Hz / Output - 15VDC, 500ma
Display - Visual LED: red, alarm; green, normal Alarm Indication Red LED and audible alarm Horn Silence Yes - temporary Mounting Semi Flush
Operating Temperature 55-86 F (13-30 C) Storage Temperature -40-150 F (-40-65 C) Instrument Dimensions Instrument Case: 5.2”H x 3.19”W x 1.97”D (132mm H x 81mm W x 50mm D) Agency Listings UL and CE
AFA 1000/1 MK3 FUME HOOD AIRFLOW MONITOR
Display Range 0-999 fpm (0 - 5.0 m/s) Alarm Range 0-999 fpm (0 - 5.0 m/s) Field Set-Up 2-point velocity calibration ( with on-screen instructions ) Accuracy Sensor / Display Resolution 1 fpm / Face Velocity Accuracy +/-10% Alarm Delays User Configurable - 0 to 60 seconds
Relay Output 4 ( 1 on board - 3 on optional plug in relay interface unit ) Analog Output 0-10V Output, Directly proportional to velocity (Optional) Relay Input 3 Comm. Port RS232 - Can be connected via Serial Interface to LAN network ( Full Software Available) Sash High Indication Yes, with separate plug-in connection Night Setback Yes External Alarm Indication Yes Power Requirement Input-120VAC, 60Hz Units Output-15VDC, 500ma Display-Visual English and Metric (user selectable) Alarm Indication Analog bar graph or Fault Timeline / LEDs: red, alarm; yellow, caution; green, normal / Digital display of velocity reading (can be turned off) Horn Silence Yes (temporary / permanent / automatic depending on type of alarm or external input) Mounting Semi Flush Operating Temperature 55-86 F ( 13-30 C ) Storage Temperature -40-150 F (-40-65 C ) Instrument Dimensions Instrument Case: 5.2”H x 3.19”W x 1.14”D ( 132mm H x 81mm W x 29mm D ) Agency Listings UL and CE
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
28
Ceiling Enclosures & Finished Backs Air Master Systems Corporation offers ceiling enclosures and finished backs to provide a professional, finished design in any setting. Ceiling enclosures and finished backs are fabricated of cold rolled steel and finished to match the fume hood superstructure.
CEILING ENCLOSURES
The ceiling enclosures are available in two types: for standard fume hoods and also for those fume hoods utilizing the optional Air Chamber. Both enclosures conceal and protect the hood ductwork, electrical conduit and other supply lines.
Example:
Model
Height
CE-111-48-18
Width
111 211 311 411 811 911 SOL
Use 111 For The Models Below:
-511 -613 -716 -HP
FINISHED BACKS Finished backs are used to close off the back of the fume hood, giving it a finished look when located in the center of a room.
Example:
*Width will be the same width as fume hood.
FINBACK-48
Width
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
29
Plumbing Accessories All Air Master Systems Corporation remote-operated fixtures come standard with four-prong handles, baked color- coded epoxy upper assemblies and control rods cut to length. Chrome and other styles are available upon request. Preplumbed services are 1/2” copper tubing for water, vacuum and non-burning gases. 1/2” black iron pipe for burning gas services. PLUMBING ACCESSORIES
Part Number
Description
FXTGAS
Gas
FXTAIR
Air
FXTVAC
Vacuum
FXTNIT Nitrogen FXTCWGN Cold Water CS36 Cupsink *Others available upon request
Remote Control Fixtures Part # FXTGAS, FXTAIR, FXTVAC, FXTNIT
Gooseneck Faucet Part # FXTGN Specify Hot or Cold
Hot and Cold Water Mixing Part # FXTCWM
Gooseneck Faucet with Vacuum Breaker Part # FXTGNWVB Specify Hot or Cold
Deck Mount Water Part # FXTDMW
90° Water Faucet Part # FXTDS
Deck Mount Gas Single Outlet Part # FXTDMG1
Deck Mount Gas Double Outlet Part # FXTDMG2
Cupsink Part # CS36
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
30
Electrical Accessories & Specifications
Pre-Wire service is completed in accordance with NEC and UL-1805 standards
Note: If the fume hood is not pre-wired, wiring in the field must be accomplished using UL listed electrical fixtures while observing NEC standards and local electrical codes.
GFI
BLOWER SWITCH
CONDUIT
GREEN (Ground) WHITE (Neutral) BLACK (Hot) RED (Blower Switch Leg)
CONDUIT
GFI
LIGHT SWITCH
GREEN (Ground) WHITE (Neutral) BLACK (Hot) RED (Blower Switch Leg)
CONDUIT
Light switch leg always wire nutted to light fixture in junction box
BLACK (Hot) WHITE (Neutral) GREEN (Ground)
LIGHT FIXTURE
Single Pole 15 Amp Light Switch Standard Black Color and Cover Plate Part # LTSW
Red Illuminated Toggle Switch with Black Cover Plate Part # BLSW
Explosion Proof Outlet Class 1, Group 1 Part # XPO
Explosion Proof Switch Class 1, Group 1 Part # XSW
208 Volt, 20 Amp Single Pole Receptacle 230, 277 or other available upon request Part # 208
120 Volt, 20 Amp Ground Fault Interrupter (GFI) Duplex Outlet Standard Black color with cover Part # GFI
Explosion Proof Light Class 1, Group 1 Available in Incandescent or fluorescent Part # XPL
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
31
Base Cabinets Although AMS is your fume hood expert, we do offer a selection of inset metal wall and base cabinets in 29”, 32” and 35” heights. When a large quantity of standard laboratory cabinets is required, please contact us for an approved distributor. AMS fume hood base cabinets conform to the method of testing and performance requirements set forth in the Scientific Equipment Furniture Association (SEFA). All ADA and hood base cabinets can be manufactured in stainless steel.
SB3512-100R
SB3212-100R
SB2912-100R
*For a wider variety of configurations, part numbers, and sizes, refer to Air Master Systems Casework Catalog.
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
32
Flammable, Acid, Vacuum Cabinets The Flammable Liquid Storage Cabinet is a “cabinet-within-a-cabinet” design with fully welded 18ga interior and exterior units. Both cabinets are completely powder coated inside and out, offering greater protection against corrosion then the standard double panel construction. This design creates a 1.5” airspace on all four sides as well as top and bottom for heat resistance up to 2400 degrees Fahrenheit. The interior of the cabinet contains one fully adjustable shelf and a 2” deep removable drip pan to capture any spills or leaks inside the cabinet. Exterior depth of the cabinet is 18” and interior depth is 14”. A 2” x 2” 12ga support angle is shipped with each cabinet for countertop installation. FLAMMABLE STORAGE CABINET
height
depth vent kit
Flammable storage cabinets can be painted any standard color or safety yellow. For synchronized self-closing doors, add -SCC to the part number. For 22” deep, replace -200 with -220. For mobile cabinets, contact your AMS representative.
SFSB3518-22R-VK
width
right hinge
SFSB2930-18
*For more part numbers and sizes, refer to Air Master Systems Casework Catalog.
ACID STORAGE CABINET
height
depth vent kit
Acid cabinet can be painted any standard color or safety blue. Add Suffix “VK” if Vent Kit is required.
SASB3518-22R-VK
width
right hinge
SASB3530-18 *For more part numbers and sizes, refer to Air Master Systems Casework Catalog.
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
33
Doors have a continuous hinge and lever type handles with a hidden 3-point lock mechanism. If a self-closing feature is required, a hydraulic closure will be attached to the doors and a custom closing system attached to the interior cabinet. The back of the cabinet has two venting holes that are plugged with 2” barrel bungs. Flammable, Acid, Vacuum Cabinets
AMS Flammable Liquid Storage Cabinets are constructed in accordance with OSHA and NFPA 30, and are UL listed.
VACUUM PUMP CABINET Additional insulation materials for noise reduction available upon request.
SB3530-20V
*For more part numbers and sizes, refer to Air Master Systems Casework Catalog.
HOOD BASE FRAMES
Standard depth for a Hood Base Frame is 29” deep. Add “-211” to any Hood Frame part number to use under our 200 Series fume hoods.
Left Hand Side Chase (HBF-3248-LH shown)
Right Hand Side Chase (HBF-3248-RH shown)
No Side Chase (HBF-3248-NC shown)
60” with Two 12” Chases (HBF-3248 shown)
Height
Part Number HBF-2948-LH
Height
Part Number HBF-2948-RH
Height
Part Number HBF-2948-NC
Height
Part Number
HBF-2960
29”
29”
29”
29”
32”
HBF-3248-LH
32”
HBF-3248-RH
32”
HBF-3248-NC
32”
HBF-3260
35”
HBF-3548-LH
35”
HBF-3548-RH
35”
HBF-3548-NC
35”
HBF-3560
*Actual Heights: 29” : 28.75” / 32” : 31.75” / 35” : 34.75”
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
34
Sash Options
To order these optional sashes, please refer to the Ordering Guide on the back cover of this catalog. The large, underlined number in each of the part numbers below is the Sash Style number to use when ordering.
COMBO HORIZONTAL/VERTICAL SASH
HORIZONTAL SASH ONLY
INTERLOCKING SASH
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
35
Sash Options
HANGING HORIZONTAL DOORS
ADDITIONAL SASH OPTIONS
• SASH ALARM:
A red light alarm activated when sashs is opened above a pre-set height.
• SASH STOP:
A device to limit sash opening, with manual override.
• AUTO SASH RETURN:
Returns sash to 18” working height when opened beyond set height.
• SASH INTERLOCK:
Allows only one sash to be opened at any time on a double-sided hood.
• DOUBLE HUNG SASH:
For larger openings with ceiling height limitations.
• SASH LOCK:
A keyed lock that keeps the sash closed if needed in a classroom setting.
• PUSHBUTTON SASH**:
Opens and closes sash with the push of a button.
• AUTO-SENSING SASH**:
**These two types of sashes have a wide range of capabilities. Please call an Air Master Systems representative or the factory to determine which application is right for your needs.
Automatically closes sash when operator walks away.
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
36
Epoxy Resin & Stainless Steel Surfaces Another key component of effective and efficient fume hood utilization is the type of work surface to use. Inappropriate work surfaces can interfere with lab processes and be a potential danger to lab personnel. Air Master Systems Corporation provides durable, high-performance epoxy resin and stainless steel surfaces that feature top quality materials and workmanship.
EPOXY RESIN
Epoxy resin fume hood surfaces provide a durable, chemical resistant work surface for the harshest laboratory environment. The work surface is surrounded by a 3/8” (10mm) integrally-molded containment rim designed to ease clean-ups and prevent hood and casework damage from large chemical spills.
Oval 3” x 6” (7.65 x 15.3cm) cup sinks are standard; locations must be specified when ordering. Other sinks sizes are available upon request.
STAINLESS STEEL Stainless steel work surfaces are fabricated of 304 stainless steel, are 1-1/4” (3.2cm) thick and dished 3/8” with a #4 smooth satin finish. Square 3” x 6” (7.65 x 15.3cm) welded cup sinks are standard; locations must be specified when ordering.
*In perchloric acid applications, 316 stainless steel is used for lab safety.
Air Master Systems Corp. • 231.798.1111 • airmastersystems.com
37
Page 1 Page 2 Page 3 Page 4 Page 5 Page 6 Page 7 Page 8 Page 9 Page 10 Page 11 Page 12 Page 13 Page 14 Page 15 Page 16 Page 17 Page 18 Page 19 Page 20 Page 21 Page 22 Page 23 Page 24 Page 25 Page 26 Page 27 Page 28 Page 29 Page 30 Page 31 Page 32 Page 33 Page 34 Page 35 Page 36 Page 37 Page 38 Page 39 Page 40 Page 41 Page 42 Page 43 Page 44 Page 45 Page 46 Page 47Made with FlippingBook - professional solution for displaying marketing and sales documents online